ログイン
言語:

WEKO3

  • トップ
  • コミュニティ
  • ランキング
AND
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "e4b910c6-ba6e-4e47-ab4a-ecc36625e3ef"}, "_deposit": {"id": "31834", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "31834"}, "status": "published"}, "_oai": {"id": "oai:niigata-u.repo.nii.ac.jp:00031834"}, "item_8_alternative_title_1": {"attribute_name": "\u305d\u306e\u4ed6\u306e\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_alternative_title": "Study on the Cooling Load Reduced by Cross Ventilation for Detached House"}]}, "item_8_biblio_info_6": {"attribute_name": "\u66f8\u8a8c\u60c5\u5831", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2008-07", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "200", "bibliographicPageStart": "197", "bibliographicVolumeNumber": "51", "bibliographic_titles": [{"bibliographic_title": "\u65e5\u672c\u5efa\u7bc9\u5b66\u4f1a\u5317\u9678\u652f\u90e8\u7814\u7a76\u5831\u544a\u96c6"}, {"bibliographic_title": "\u65e5\u672c\u5efa\u7bc9\u5b66\u4f1a\u5317\u9678\u652f\u90e8\u7814\u7a76\u5831\u544a\u96c6", "bibliographic_titleLang": "en"}]}]}, "item_8_description_4": {"attribute_name": "\u6284\u9332", "attribute_value_mlt": [{"subitem_description": "\u590f\u5b63\u306e\u51b7\u623f\u7528\u30a8\u30cd\u30eb\u30ae\u30fc\u306e\u5927\u5e45\u306a\u5897\u52a0\u304c\u61f8\u5ff5\u3055\u308c\u3066\u3044\u308b\u3002\u672c\u7814\u7a76\u3067\u306f\u3001\u5168\u56fd842\u90fd\u5e02\u306b\u304a\u3044\u3066\u901a\u98a8\u3092\u5229\u7528\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u524a\u6e1b\u53ef\u80fd\u306a\u51b7\u623f\u7528\u30a8\u30cd\u30eb\u30ae\u30fc\u3092\u6c42\u3081\u3001\u901a\u98a8\u3092\u5229\u7528\u3059\u308b\u3053\u3068\u306b\u3088\u308b\u51b7\u623f\u8ca0\u8377\u524a\u6e1b\u52b9\u679c\u3092\u660e\u3089\u304b\u306b\u3059\u308b\u3002\u7a93\u3092\u90e8\u5206\u7684\u306b\u9589\u9396\u3057\u3066\u3082\u3001\u3059\u3079\u3066\u306e\u7a93\u3092\u958b\u653e\u3057\u305f\u5834\u5408\u3088\u308a\u3001\u51b7\u623f\u8ca0\u8377\u524a\u6e1b\u7387\u3092\u9ad8\u304f\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3042\u308b\u3002\u5e74\u9593\u51b7\u623f\u8ca0\u8377\u3084\u51b7\u623f\u524a\u6e1b\u91cf\u306f\u5317\u6d77\u9053\u304b\u3089\u5357\u4e0b\u3059\u308b\u306b\u5f93\u3044\u76f8\u5bfe\u7684\u306b\u5927\u304d\u304f\u306a\u308a\u3001\u51b7\u623f\u8ca0\u8377\u524a\u6e1b\u7387\u306f\u76f8\u5bfe\u7684\u306b\u4f4e\u003c\u306a\u308b\u3002\u4e00\u7b87\u6240\u4ee5\u4e0a\u901a\u98a8\u5229\u7528\u304c\u53ef\u80fd\u306a\u5834\u5408\u3068\u6bd4\u3079\u3066\u3001\u5ba4\u65ad\u9762\u306e50%\u4ee5\u4e0a\u304c\u901a\u98a8\u5229\u7528\u304c\u53ef\u80fd\u306a\u5834\u5408\u3067\u306f\u51b7\u623f\u8ca0\u8377\u524a\u6e1b\u7387\u304c\u4f4e\u4e0b\u3057\u305f\u3002", "subitem_description_type": "Abstract"}]}, "item_8_full_name_3": {"attribute_name": "\u8457\u8005\u5225\u540d", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "173987", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Tomioka, Seiko"}]}, {"nameIdentifiers": [{"nameIdentifier": "173988", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Akabayashi, Shin-ichi"}]}, {"nameIdentifiers": [{"nameIdentifier": "173989", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Sakaguchi, Jun"}]}, {"nameIdentifiers": [{"nameIdentifier": "173990", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Yamaguchi, Jun"}]}]}, "item_8_publisher_7": {"attribute_name": "\u51fa\u7248\u8005", "attribute_value_mlt": [{"subitem_publisher": "\u65e5\u672c\u5efa\u7bc9\u5b66\u4f1a"}]}, "item_8_rights_15": {"attribute_name": "\u6a29\u5229", "attribute_value_mlt": [{"subitem_rights": "\u793e\u56e3\u6cd5\u4eba\u65e5\u672c\u5efa\u7bc9\u5b66\u4f1a"}]}, "item_8_select_19": {"attribute_name": "\u8457\u8005\u7248\u30d5\u30e9\u30b0", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_8_source_id_11": {"attribute_name": "\u66f8\u8a8c\u30ec\u30b3\u30fc\u30c9ID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00188761", "subitem_source_identifier_type": "NCID"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "03859622", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "\u8457\u8005", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "\u5bcc\u5ca1, \u8aa0\u5b50"}], "nameIdentifiers": [{"nameIdentifier": "173983", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u8d64\u6797, \u4f38\u4e00"}], "nameIdentifiers": [{"nameIdentifier": "173984", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u5742\u53e3, \u6df3"}], "nameIdentifiers": [{"nameIdentifier": "173985", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u5c71\u53e3, \u9075"}], "nameIdentifiers": [{"nameIdentifier": "173986", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "\u30d5\u30a1\u30a4\u30eb\u60c5\u5831", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-08-27"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "ZD_51_197-200.pdf", "filesize": [{"value": "1.3 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1300000.0, "url": {"label": "ZD_51_197-200.pdf", "url": "https://niigata-u.repo.nii.ac.jp/record/31834/files/ZD_51_197-200.pdf"}, "version_id": "81530a74-0cf0-4b38-b57a-d99b6a917910"}]}, "item_keyword": {"attribute_name": "\u30ad\u30fc\u30ef\u30fc\u30c9", "attribute_value_mlt": [{"subitem_subject": "Cross Ventilation", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Cooling Load", "subitem_subject_scheme": "Other"}, {"subitem_subject": "\u901a\u98a8", "subitem_subject_scheme": "Other"}, {"subitem_subject": "\u51b7\u623f\u8ca0\u8377", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "\u8a00\u8a9e", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "\u6238\u5efa\u4f4f\u5b85\u3092\u5bfe\u8c61\u3068\u3057\u305f\u901a\u98a8\u6027\u80fd\u8a55\u4fa1\u306b\u95a2\u3059\u308b\u7814\u7a76 : \u305d\u306e17 \u901a\u98a8\u306b\u3088\u308b\u51b7\u623f\u8ca0\u8377\u524a\u6e1b\u52b9\u679c\u306b\u95a2\u3059\u308b\u7814\u7a76", "item_titles": {"attribute_name": "\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_title": "\u6238\u5efa\u4f4f\u5b85\u3092\u5bfe\u8c61\u3068\u3057\u305f\u901a\u98a8\u6027\u80fd\u8a55\u4fa1\u306b\u95a2\u3059\u308b\u7814\u7a76 : \u305d\u306e17 \u901a\u98a8\u306b\u3088\u308b\u51b7\u623f\u8ca0\u8377\u524a\u6e1b\u52b9\u679c\u306b\u95a2\u3059\u308b\u7814\u7a76"}, {"subitem_title": "\u6238\u5efa\u4f4f\u5b85\u3092\u5bfe\u8c61\u3068\u3057\u305f\u901a\u98a8\u6027\u80fd\u8a55\u4fa1\u306b\u95a2\u3059\u308b\u7814\u7a76 : \u305d\u306e17 \u901a\u98a8\u306b\u3088\u308b\u51b7\u623f\u8ca0\u8377\u524a\u6e1b\u52b9\u679c\u306b\u95a2\u3059\u308b\u7814\u7a76", "subitem_title_language": "en"}]}, "item_type_id": "8", "owner": "1", "path": ["453/457", "468/1817/1833"], "permalink_uri": "http://hdl.handle.net/10191/18292", "pubdate": {"attribute_name": "\u516c\u958b\u65e5", "attribute_value": "2012-06-05"}, "publish_date": "2012-06-05", "publish_status": "0", "recid": "31834", "relation": {}, "relation_version_is_last": true, "title": ["\u6238\u5efa\u4f4f\u5b85\u3092\u5bfe\u8c61\u3068\u3057\u305f\u901a\u98a8\u6027\u80fd\u8a55\u4fa1\u306b\u95a2\u3059\u308b\u7814\u7a76 : \u305d\u306e17 \u901a\u98a8\u306b\u3088\u308b\u51b7\u623f\u8ca0\u8377\u524a\u6e1b\u52b9\u679c\u306b\u95a2\u3059\u308b\u7814\u7a76"], "weko_shared_id": null}
  1. 0 資料タイプ別
  2. 04 会議発表論文
  1. 230 大学院自然科学研究科
  2. 40 学会発表資料
  3. 03 日本建築学会

戸建住宅を対象とした通風性能評価に関する研究 : その17 通風による冷房負荷削減効果に関する研究

http://hdl.handle.net/10191/18292
a40b0cea-96a6-4842-a59c-59f6e0a849c0
名前 / ファイル ライセンス アクション
ZD_51_197-200.pdf ZD_51_197-200.pdf (1.3 MB)
Item type 会議発表論文 / Conference Paper(1)
公開日 2012-06-05
タイトル
タイトル 戸建住宅を対象とした通風性能評価に関する研究 : その17 通風による冷房負荷削減効果に関する研究
タイトル
言語 en
タイトル 戸建住宅を対象とした通風性能評価に関する研究 : その17 通風による冷房負荷削減効果に関する研究
言語
言語 jpn
キーワード
主題Scheme Other
主題 Cross Ventilation
キーワード
主題Scheme Other
主題 Cooling Load
キーワード
主題Scheme Other
主題 通風
キーワード
主題Scheme Other
主題 冷房負荷
資源タイプ
資源 http://purl.org/coar/resource_type/c_5794
タイプ conference paper
その他のタイトル
その他のタイトル Study on the Cooling Load Reduced by Cross Ventilation for Detached House
著者 富岡, 誠子

× 富岡, 誠子

WEKO 173983

富岡, 誠子

Search repository
赤林, 伸一

× 赤林, 伸一

WEKO 173984

赤林, 伸一

Search repository
坂口, 淳

× 坂口, 淳

WEKO 173985

坂口, 淳

Search repository
山口, 遵

× 山口, 遵

WEKO 173986

山口, 遵

Search repository
著者別名
識別子
識別子 173987
識別子Scheme WEKO
姓名
姓名 Tomioka, Seiko
著者別名
識別子
識別子 173988
識別子Scheme WEKO
姓名
姓名 Akabayashi, Shin-ichi
著者別名
識別子
識別子 173989
識別子Scheme WEKO
姓名
姓名 Sakaguchi, Jun
著者別名
識別子
識別子 173990
識別子Scheme WEKO
姓名
姓名 Yamaguchi, Jun
抄録
内容記述タイプ Abstract
内容記述 夏季の冷房用エネルギーの大幅な増加が懸念されている。本研究では、全国842都市において通風を利用することにより削減可能な冷房用エネルギーを求め、通風を利用することによる冷房負荷削減効果を明らかにする。窓を部分的に閉鎖しても、すべての窓を開放した場合より、冷房負荷削減率を高くすることが可能である。年間冷房負荷や冷房削減量は北海道から南下するに従い相対的に大きくなり、冷房負荷削減率は相対的に低<なる。一箇所以上通風利用が可能な場合と比べて、室断面の50%以上が通風利用が可能な場合では冷房負荷削減率が低下した。
書誌情報 日本建築学会北陸支部研究報告集
en : 日本建築学会北陸支部研究報告集

巻 51, p. 197-200, 発行日 2008-07
出版者
出版者 日本建築学会
ISSN
収録物識別子タイプ ISSN
収録物識別子 03859622
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN00188761
権利
権利情報 社団法人日本建築学会
著者版フラグ
値 publisher
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 09:47:26.770941
Show All versions

Share

Mendeley CiteULike Twitter Facebook Print Addthis

Cite as

Export

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by CERN Data Centre & Invenio


Powered by CERN Data Centre & Invenio