{"_buckets": {"deposit": "dc249a97-48f9-42ce-81e7-ca31cf8b0afd"}, "_deposit": {"id": "25853", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "25853"}, "status": "published"}, "_oai": {"id": "oai:niigata-u.repo.nii.ac.jp:00025853", "sets": ["456", "1321"]}, "item_7_alternative_title_1": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Accidental swallowing of a Fixed bridge in the Trachea: Report of Two Cases"}]}, "item_7_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1998-12", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "58", "bibliographicPageStart": "55", "bibliographicVolumeNumber": "28", "bibliographic_titles": [{"bibliographic_title": "新潟歯学会雑誌"}, {"bibliographic_title": "新潟歯学会雑誌", "bibliographic_titleLang": "en"}]}]}, "item_7_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Accidental swallowing or aspiration of dentures, cast objects and dental instruments often occur during dental treatment. Most of them are swallowed in the stomach. On occasion, however they are swallowed in the trachea. Two cases with accidental swallowing of a fixed bridge in the trachea were reported. Case 1, A 72-year-old man accidentally swallowed a 65④③ fixed bridge during its removal. He had a paroxysmal cough. A chest radiograph showed a left bronchial foreign body. Case 2, A 89-year-old man accidentally swallowed a ④56⑦ fixed bridge during its removal. The accident was accompained by no sign indicative of aspiration into the airway. However, a chest radiograph showed it to be lodged in the right bronchus. The fixed bridges in the bronchus were removed by bronchoscopic procedures on the day of the accident without any complication.", "subitem_description_type": "Abstract"}, {"subitem_description": "歯科に関連した歯科用補綴物、歯科用器具などの誤嚥は時々みられるが、これらの多くは消化管に入り、気道内に入ることは比較的稀である。今回、私達は、歯科開業医においてブリッジ撤去中にブリッジを誤嚥し、気管内に吸引された2例についてその概要を報告した。症例1は、72歳、男性で、某歯科において65④③ブリッジを撤去中誤嚥。直後に咳嗽発作があり,胸部単純Ⅹ線写真でブリッジが左側気管支に金属物体の陰影が確認された。症例2は、89歳、男性で、某歯科において④56⑦ブリッジ撤去中誤嚥。咳嗽発作等の自覚症状はなかったが、胸部単純Ⅹ線写真で右側気管支に陰影が確認された。2例とも、即日、気管支鏡直視下に異物摘出術を行ったが、術中、術後の合併症等は認めなかった。", "subitem_description_type": "Abstract"}]}, "item_7_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "152574", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Yokobayashi, Toshio"}]}, {"nameIdentifiers": [{"nameIdentifier": "152575", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Shimizu, Takeshi"}]}, {"nameIdentifiers": [{"nameIdentifier": "152576", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Goto, Hideki"}]}, {"nameIdentifiers": [{"nameIdentifier": "152577", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Kano, Hiroyuki"}]}]}, "item_7_publisher_7": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "新潟歯学会"}]}, "item_7_select_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_7_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN0018300X", "subitem_source_identifier_type": "NCID"}]}, "item_7_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "03850153", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "横林, 敏夫"}], "nameIdentifiers": [{"nameIdentifier": "152570", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "清水, 武"}], "nameIdentifiers": [{"nameIdentifier": "152571", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "五島, 秀樹"}], "nameIdentifiers": [{"nameIdentifier": "152572", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "加納, 浩之"}], "nameIdentifiers": [{"nameIdentifier": "152573", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-08-19"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "NS_28(2)_55-58.pdf", "filesize": [{"value": "1.6 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1600000.0, "url": {"label": "NS_28(2)_55-58.pdf", "url": "https://niigata-u.repo.nii.ac.jp/record/25853/files/NS_28(2)_55-58.pdf"}, "version_id": "aa5ba4e6-0b31-4f43-8deb-ac3c370492de"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "fixed Bridge", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ブリッジ", "subitem_subject_scheme": "Other"}, {"subitem_subject": "bronchial foreign body", "subitem_subject_scheme": "Other"}, {"subitem_subject": "気管支異物", "subitem_subject_scheme": "Other"}, {"subitem_subject": "bronchoscopic procedure", "subitem_subject_scheme": "Other"}, {"subitem_subject": "気管支ファイバー", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "気管内に吸引されたブリッジの2例", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "気管内に吸引されたブリッジの2例"}, {"subitem_title": "気管内に吸引されたブリッジの2例", "subitem_title_language": "en"}]}, "item_type_id": "7", "owner": "1", "path": ["456", "1321"], "permalink_uri": "http://hdl.handle.net/10191/23080", "pubdate": {"attribute_name": "公開日", "attribute_value": "2013-08-22"}, "publish_date": "2013-08-22", "publish_status": "0", "recid": "25853", "relation": {}, "relation_version_is_last": true, "title": ["気管内に吸引されたブリッジの2例"], "weko_shared_id": null}
  1. 260 大学院医歯学総合研究科(歯)
  2. 20 紀要
  3. 01 新潟歯学会雑誌
  4. 第28巻第2号
  1. 0 資料タイプ別
  2. 03 紀要論文

気管内に吸引されたブリッジの2例

http://hdl.handle.net/10191/23080
http://hdl.handle.net/10191/23080
bc75d8c0-81b8-4217-ba34-cdb0169c49ca
名前 / ファイル ライセンス アクション
NS_28(2)_55-58.pdf NS_28(2)_55-58.pdf (1.6 MB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2013-08-22
タイトル
タイトル 気管内に吸引されたブリッジの2例
タイトル
言語 en
タイトル 気管内に吸引されたブリッジの2例
言語
言語 jpn
キーワード
主題Scheme Other
主題 fixed Bridge
キーワード
主題Scheme Other
主題 ブリッジ
キーワード
主題Scheme Other
主題 bronchial foreign body
キーワード
主題Scheme Other
主題 気管支異物
キーワード
主題Scheme Other
主題 bronchoscopic procedure
キーワード
主題Scheme Other
主題 気管支ファイバー
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
その他のタイトル
その他のタイトル Accidental swallowing of a Fixed bridge in the Trachea: Report of Two Cases
著者 横林, 敏夫

× 横林, 敏夫

WEKO 152570

横林, 敏夫

Search repository
清水, 武

× 清水, 武

WEKO 152571

清水, 武

Search repository
五島, 秀樹

× 五島, 秀樹

WEKO 152572

五島, 秀樹

Search repository
加納, 浩之

× 加納, 浩之

WEKO 152573

加納, 浩之

Search repository
著者別名
識別子 152574
識別子Scheme WEKO
姓名 Yokobayashi, Toshio
著者別名
識別子 152575
識別子Scheme WEKO
姓名 Shimizu, Takeshi
著者別名
識別子 152576
識別子Scheme WEKO
姓名 Goto, Hideki
著者別名
識別子 152577
識別子Scheme WEKO
姓名 Kano, Hiroyuki
抄録
内容記述タイプ Abstract
内容記述 Accidental swallowing or aspiration of dentures, cast objects and dental instruments often occur during dental treatment. Most of them are swallowed in the stomach. On occasion, however they are swallowed in the trachea. Two cases with accidental swallowing of a fixed bridge in the trachea were reported. Case 1, A 72-year-old man accidentally swallowed a 65④③ fixed bridge during its removal. He had a paroxysmal cough. A chest radiograph showed a left bronchial foreign body. Case 2, A 89-year-old man accidentally swallowed a ④56⑦ fixed bridge during its removal. The accident was accompained by no sign indicative of aspiration into the airway. However, a chest radiograph showed it to be lodged in the right bronchus. The fixed bridges in the bronchus were removed by bronchoscopic procedures on the day of the accident without any complication.
抄録
内容記述タイプ Abstract
内容記述 歯科に関連した歯科用補綴物、歯科用器具などの誤嚥は時々みられるが、これらの多くは消化管に入り、気道内に入ることは比較的稀である。今回、私達は、歯科開業医においてブリッジ撤去中にブリッジを誤嚥し、気管内に吸引された2例についてその概要を報告した。症例1は、72歳、男性で、某歯科において65④③ブリッジを撤去中誤嚥。直後に咳嗽発作があり,胸部単純Ⅹ線写真でブリッジが左側気管支に金属物体の陰影が確認された。症例2は、89歳、男性で、某歯科において④56⑦ブリッジ撤去中誤嚥。咳嗽発作等の自覚症状はなかったが、胸部単純Ⅹ線写真で右側気管支に陰影が確認された。2例とも、即日、気管支鏡直視下に異物摘出術を行ったが、術中、術後の合併症等は認めなかった。
書誌情報 新潟歯学会雑誌
en : 新潟歯学会雑誌

巻 28, 号 2, p. 55-58, 発行日 1998-12
出版者
出版者 新潟歯学会
ISSN
収録物識別子タイプ ISSN
収録物識別子 03850153
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN0018300X
著者版フラグ
値 publisher
戻る
0