ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "7d54ec23-cec1-4ffa-a176-da93ed043855"}, "_deposit": {"id": "9859", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "9859"}, "status": "published"}, "_oai": {"id": "oai:niigata-u.repo.nii.ac.jp:00009859", "sets": ["456", "948"]}, "item_7_alternative_title_1": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "The Newly Established Diagnostic Criteria of Diabetes Mellitus (Rapid Progress of Diagnosis and Treatment in Diabetes Mellitus)"}]}, "item_7_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2011-12", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "12", "bibliographicPageEnd": "651", "bibliographicPageStart": "648", "bibliographicVolumeNumber": "125", "bibliographic_titles": [{"bibliographic_title": "新潟医学会雑誌"}, {"bibliographic_title": "新潟医学会雑誌", "bibliographic_titleLang": "en"}]}]}, "item_7_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Diagnosis of diabetes mellitus Confirmation of chronic hyperglycemia is essential for the diagnosis of diabetes mellitus. When plasma glucose levels are used to determine the categories of glycemia, patients are classified as having a diabetes if they meet one of the following criteria: ((1)) fasting plasma glucose level of ≧ 126mg/dl; ((2)) 2-h value of ≧ 200mg/dl in 75g oral glucose tolerance test (OGTT) ; or ((3)) casual plasma glucose level of ≧ 200mg/dl. Normal type is defined as fasting plasma glucose level of \u003c110mg/dl and 2-h value \u003c 140mg/dl in OGTT. According to the current revision, in addition to the earlier listed plasma glucose values, hemoglobin A1c (HbAI1c) has been given a more prominent position as one of the diagnostic criteria. That is, ((4)) HbA1c ≧ 6.5% is now also considered to indicate diabetic type. The value of HbA1c, which is equivalent to the internationally used HbA1c (%) (HbA1c [NGSP]) defined by the NGSP (National Glycohemoglobin Standardization Program), is expressed by adding 0.4% to the HbAI1c (JDS) (%) defined by the Japan Diabetes Society (JDS).", "subitem_description_type": "Abstract"}]}, "item_7_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "68097", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Yahata, Kazuaki"}]}]}, "item_7_publisher_7": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "新潟医学会"}]}, "item_7_select_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_7_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00182415", "subitem_source_identifier_type": "NCID"}]}, "item_7_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "00290440", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "八幡, 和明"}], "nameIdentifiers": [{"nameIdentifier": "68096", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-08-06"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "125(12)_648-651.pdf", "filesize": [{"value": "722.6 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 722600.0, "url": {"label": "125(12)_648-651.pdf", "url": "https://niigata-u.repo.nii.ac.jp/record/9859/files/125(12)_648-651.pdf"}, "version_id": "9dd141cc-b846-452a-95c9-09071c65ca44"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "diagnostic criteria", "subitem_subject_scheme": "Other"}, {"subitem_subject": "HbA1c (NGSP)", "subitem_subject_scheme": "Other"}, {"subitem_subject": "HbA1c (JDS)", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "1 新しい糖尿病の診断基準(糖尿病の診断と治療の急速な展開,第661回新潟医学会)", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "1 新しい糖尿病の診断基準(糖尿病の診断と治療の急速な展開,第661回新潟医学会)"}, {"subitem_title": "1 新しい糖尿病の診断基準(糖尿病の診断と治療の急速な展開,第661回新潟医学会)", "subitem_title_language": "en"}]}, "item_type_id": "7", "owner": "1", "path": ["456", "948"], "permalink_uri": "http://hdl.handle.net/10191/29323", "pubdate": {"attribute_name": "公開日", "attribute_value": "2014-07-29"}, "publish_date": "2014-07-29", "publish_status": "0", "recid": "9859", "relation": {}, "relation_version_is_last": true, "title": ["1 新しい糖尿病の診断基準(糖尿病の診断と治療の急速な展開,第661回新潟医学会)"], "weko_shared_id": null}
  1. 0 資料タイプ別
  2. 03 紀要論文
  1. 250 大学院医歯学総合研究科(医)
  2. 20 紀要
  3. 02 新潟医学会雑誌
  4. 第125巻第12号

1 新しい糖尿病の診断基準(糖尿病の診断と治療の急速な展開,第661回新潟医学会)

http://hdl.handle.net/10191/29323
http://hdl.handle.net/10191/29323
4bbb6aa4-0c07-43b4-a9c0-690ab3ad928b
名前 / ファイル ライセンス アクション
125(12)_648-651.pdf 125(12)_648-651.pdf (722.6 kB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2014-07-29
タイトル
タイトル 1 新しい糖尿病の診断基準(糖尿病の診断と治療の急速な展開,第661回新潟医学会)
タイトル
言語 en
タイトル 1 新しい糖尿病の診断基準(糖尿病の診断と治療の急速な展開,第661回新潟医学会)
言語
言語 jpn
キーワード
主題Scheme Other
主題 diagnostic criteria
キーワード
主題Scheme Other
主題 HbA1c (NGSP)
キーワード
主題Scheme Other
主題 HbA1c (JDS)
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
その他のタイトル
その他のタイトル The Newly Established Diagnostic Criteria of Diabetes Mellitus (Rapid Progress of Diagnosis and Treatment in Diabetes Mellitus)
著者 八幡, 和明

× 八幡, 和明

WEKO 68096

八幡, 和明

Search repository
著者別名
識別子 68097
識別子Scheme WEKO
姓名 Yahata, Kazuaki
抄録
内容記述タイプ Abstract
内容記述 Diagnosis of diabetes mellitus Confirmation of chronic hyperglycemia is essential for the diagnosis of diabetes mellitus. When plasma glucose levels are used to determine the categories of glycemia, patients are classified as having a diabetes if they meet one of the following criteria: ((1)) fasting plasma glucose level of ≧ 126mg/dl; ((2)) 2-h value of ≧ 200mg/dl in 75g oral glucose tolerance test (OGTT) ; or ((3)) casual plasma glucose level of ≧ 200mg/dl. Normal type is defined as fasting plasma glucose level of <110mg/dl and 2-h value < 140mg/dl in OGTT. According to the current revision, in addition to the earlier listed plasma glucose values, hemoglobin A1c (HbAI1c) has been given a more prominent position as one of the diagnostic criteria. That is, ((4)) HbA1c ≧ 6.5% is now also considered to indicate diabetic type. The value of HbA1c, which is equivalent to the internationally used HbA1c (%) (HbA1c [NGSP]) defined by the NGSP (National Glycohemoglobin Standardization Program), is expressed by adding 0.4% to the HbAI1c (JDS) (%) defined by the Japan Diabetes Society (JDS).
書誌情報 新潟医学会雑誌
en : 新潟医学会雑誌

巻 125, 号 12, p. 648-651, 発行日 2011-12
出版者
出版者 新潟医学会
ISSN
収録物識別子タイプ ISSN
収録物識別子 00290440
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN00182415
著者版フラグ
値 publisher
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 18:10:39.627805
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3