Application of a Non-invasive System for Monitoring Plasma Indocyanine Green Dynamics in Rats

http://hdl.handle.net/10191/33153
http://hdl.handle.net/10191/33153
338b5675-e9bc-4b77-bbea-c9886a747e6b
名前 / ファイル ライセンス アクション
44(1)_19-22.pdf 44(1)_19-22.pdf (468.1 kB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2015-08-27
タイトル
タイトル Application of a Non-invasive System for Monitoring Plasma Indocyanine Green Dynamics in Rats
タイトル
タイトル Application of a Non-invasive System for Monitoring Plasma Indocyanine Green Dynamics in Rats
言語 en
言語
言語 jpn
キーワード
主題Scheme Other
主題 hepatic dye test
キーワード
主題Scheme Other
主題 dye metabolism
キーワード
主題Scheme Other
主題 liver
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
著者 Sakaguchi, Takeo

× Sakaguchi, Takeo

WEKO 52961

Sakaguchi, Takeo

Search repository
Fujita, Nobuhiro

× Fujita, Nobuhiro

WEKO 52962

Fujita, Nobuhiro

Search repository
Ishizuka, Dai

× Ishizuka, Dai

WEKO 52963

Ishizuka, Dai

Search repository
Aono, Takashi

× Aono, Takashi

WEKO 52964

Aono, Takashi

Search repository
抄録
内容記述タイプ Abstract
内容記述 A non-invasive indocyanine green (IGG) monitoring system was applied to rats to estimate the plasma disappearance rate of ICG (ICG-K). The optical sensor for monitoring the ICG concentration was attached to the skin of the forepaw of the posterior leg. When ICG 0.5 mg/kg (200μl) was injected into the jugular vein as a bolus, a plasma disappearance curve for ICG was obtained. The curve shifted downwards accoring to the decrease in the ICG dosage, and reproducible values in ICG-K were obtained when 0.25 mg/kg and 0.5 mg/kg ICG were injected. The curve obtained from the monitoring system was similar to that from the blood sampling method. It was also noted that the coefficients of variation in systemic arterial blood pressure and portal venous blood flow were both within 5 during the 15-min ICG examination. These results suggest that this ICG monitoring system is suitable for investigating the ICG metabolism with stable systemic and portal circulation in the rat.
書誌情報 Acta medica et biologica
en : Acta medica et biologica

巻 44, 号 1, p. 19-22, 発行日 1996-03
出版者
出版者 Niigata University School of Medicine
ISSN
収録物識別子タイプ ISSN
収録物識別子 05677734
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AA00508361
著者版フラグ
値 publisher
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 19:38:32.674256
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3