ログイン
言語:

WEKO3

  • トップ
  • ランキング
To

Field does not validate

To

Field does not validate

To
lat lon distance


インデックスリンク

インデックスツリー

  • RootNode

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 0 資料タイプ別
  2. 03 紀要論文
  1. 250 大学院医歯学総合研究科(医)
  2. 20 紀要
  3. 01 Acta medica et biologica
  4. Vol.46 No.3

Correlates of Restenosis after Deployment of the PalmazSchatz Stent: The Importance of Diabetes Mellitus in Patients with Coronary Artery Disease

http://hdl.handle.net/10191/33087
http://hdl.handle.net/10191/33087
38d30279-3a1b-4aa7-89d1-08a1d3518310
名前 / ファイル ライセンス アクション
46(3)_101-107.pdf 46(3)_101-107.pdf (850.7 kB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2015-08-21
タイトル
タイトル Correlates of Restenosis after Deployment of the PalmazSchatz Stent: The Importance of Diabetes Mellitus in Patients with Coronary Artery Disease
タイトル
タイトル Correlates of Restenosis after Deployment of the PalmazSchatz Stent: The Importance of Diabetes Mellitus in Patients with Coronary Artery Disease
言語 en
言語
言語 eng
キーワード
主題Scheme Other
主題 Palmaz-Schatz stent
キーワード
主題Scheme Other
主題 restenosis
キーワード
主題Scheme Other
主題 diabetes mellitus
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
著者 Itoh, Eiichi

× Itoh, Eiichi

WEKO 52596

Itoh, Eiichi

Search repository
Oda, Hirotaka

× Oda, Hirotaka

WEKO 52597

Oda, Hirotaka

Search repository
Miida, Tsutomu

× Miida, Tsutomu

WEKO 52598

Miida, Tsutomu

Search repository
Toeda, Tetsurou

× Toeda, Tetsurou

WEKO 52599

Toeda, Tetsurou

Search repository
Higuma, Norio

× Higuma, Norio

WEKO 52600

Higuma, Norio

Search repository
抄録
内容記述タイプ Abstract
内容記述 This study was done to determine the correlates of restenosis after deployment of the PalmazSchatz stent. Clinical, procedural and quantitative angiographic data from 85 consecutive patients (92 lesions) with successful stent deployment (diameter stenosis <50%) were analyzed. All patients had follow-up angiography 6.5±2.5 months after stenting. Minimal luminal diameters and diameter stenosis before and immediately after the procedure were 0.82±0.35 mm, 67.8±11.5% and 2.96±2.16mm, 0.9±19.3%. The number of deployed stents was 1.1 ±0.4. At follow-up, minimal luminal diameter was 1.93±0.75 mm and diameter stenosis was 23.4±27.6%. Restenosis (diameter stenosis≧50%)occurred in 16 (17.4%) lesions. The incidence of diabetes was significantly higher in the restenosis group than non-restenosis group (62.5% vs. 19.7%; p=0.0005), and lesion length was longer (16.2± 9.2 mm vs. 10.0±6.2 mm; p=0.0077). Other variables did not show differences between the two groups. Using logistic regression analysis, a multivariate study showed that restenosis was correlated only with diabetes (p < 0.0001, RR=18.18, 95%CI=3.38-97.68). In diabetic patients, HbAlc was higher in the restenosis group than the non-restenosis group at the time of stent deployment (7.6±0.7% vs. 6.3±1.4%; p=0.0484). Conclusion: Restenosis after the Palmaz-Schatz stent is strongly concerned with diabetes mellitus.
書誌情報 Acta medica et biologica
en : Acta medica et biologica

巻 46, 号 3, p. 101-107, 発行日 1998-09
出版者
出版者 Niigata University School of Medicine
ISSN
収録物識別子タイプ ISSN
収録物識別子 05677734
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AA00508361
著者版フラグ
値 publisher
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 19:40:21.921842
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

Itoh, Eiichi, Oda, Hirotaka, Miida, Tsutomu, Toeda, Tetsurou, Higuma, Norio, 1998, Correlates of Restenosis after Deployment of the PalmazSchatz Stent: The Importance of Diabetes Mellitus in Patients with Coronary Artery Disease: Niigata University School of Medicine, 101–107 p.

Loading...

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3