ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "437a551f-d55c-4ab3-bb11-98536f6809dd"}, "_deposit": {"id": "6210", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "6210"}, "status": "published"}, "_oai": {"id": "oai:niigata-u.repo.nii.ac.jp:00006210", "sets": ["456", "579"]}, "item_7_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "83", "bibliographicPageStart": "77", "bibliographicVolumeNumber": "54", "bibliographic_titles": [{"bibliographic_title": "Acta medica et biologica"}, {"bibliographic_title": "Acta medica et biologica", "bibliographic_titleLang": "en"}]}]}, "item_7_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The present study investigated the basic architectonics of a micro particle image velocimetry (PIV) system and measured shear stress in a model of hepatic microcirculation for the purpose of understanding mechanical stress in small-for-size graft liver transplantation. The flow velocity was measured using a micro PIV system in a straight confluence, with bifurcation channels of the hepatic sinusoid model made of a clear acrylics that was 300μm in width and 100μm in height. In the micro PIV system, two strobes as a light source illuminated an object from underneath, and its visual flow images were recorded into a computer using a high-resolution CCD camera. The flow visualization was performed by adding distilled water to proper nylon tracer particles of 1μm in diameter (specific gravity: 1.02). The experimental velocity profile measured by this micro PIV system was in good accordance with both the results obtained using the three-dimensional Navier-Strokes equations on a square tube and Hagen-Poiseulle equations on a circular tube, which confirmed the suitability of this measurement system. The flow velocity after both confluence and branching in the model of hepatic circulation very rapidly became similar to that of the straight flow. The wall shear stress was calculated using an equation of τ=μ・du/dy, based on the measured mean velocity distribution. The measurement data of shear stress in the straight flow was accurate with an error of 6%. This micro PIV system had sufficient reliability for measuring the shear stress in hepatic microcirculation and serve as a new instrument for understanding pathological conditions in hepatic microcirculation in small-for-size liver transplantation.", "subitem_description_type": "Abstract"}]}, "item_7_publisher_7": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Niigata University School of Medicine"}]}, "item_7_rights_15": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "本文データは学協会の許諾に基づきCiNiiから複製したものである"}]}, "item_7_select_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_7_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA00508361", "subitem_source_identifier_type": "NCID"}]}, "item_7_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "05677734", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Sato, Yoshinobu"}], "nameIdentifiers": [{"nameIdentifier": "51673", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Fujisawa, Nobuyuki"}], "nameIdentifiers": [{"nameIdentifier": "51674", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hatakeyama, Katsuyoshi"}], "nameIdentifiers": [{"nameIdentifier": "51675", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-08-06"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "110006483825.pdf", "filesize": [{"value": "905.1 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 905100.0, "url": {"label": "110006483825.pdf", "url": "https://niigata-u.repo.nii.ac.jp/record/6210/files/110006483825.pdf"}, "version_id": "2a501d5a-e611-45b1-8a56-1719785817bd"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "flow visualization", "subitem_subject_scheme": "Other"}, {"subitem_subject": "micro PIV", "subitem_subject_scheme": "Other"}, {"subitem_subject": "microcirculation", "subitem_subject_scheme": "Other"}, {"subitem_subject": "shear stress", "subitem_subject_scheme": "Other"}, {"subitem_subject": "liver transplantation", "subitem_subject_scheme": "Other"}, {"subitem_subject": "velocity measurement", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Experimental Model for Shear Stress Measurement in Vascular Circulation by Micro Particle Image Velocimetry", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Experimental Model for Shear Stress Measurement in Vascular Circulation by Micro Particle Image Velocimetry"}, {"subitem_title": "Experimental Model for Shear Stress Measurement in Vascular Circulation by Micro Particle Image Velocimetry", "subitem_title_language": "en"}]}, "item_type_id": "7", "owner": "1", "path": ["456", "579"], "permalink_uri": "http://hdl.handle.net/10191/19591", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-09-28"}, "publish_date": "2012-09-28", "publish_status": "0", "recid": "6210", "relation": {}, "relation_version_is_last": true, "title": ["Experimental Model for Shear Stress Measurement in Vascular Circulation by Micro Particle Image Velocimetry"], "weko_shared_id": null}
  1. 0 資料タイプ別
  2. 03 紀要論文
  1. 250 大学院医歯学総合研究科(医)
  2. 20 紀要
  3. 01 Acta medica et biologica
  4. Vol.54 No.3

Experimental Model for Shear Stress Measurement in Vascular Circulation by Micro Particle Image Velocimetry

http://hdl.handle.net/10191/19591
http://hdl.handle.net/10191/19591
44b92e8b-6d4b-4e41-9ac9-d0fabb3998ce
名前 / ファイル ライセンス アクション
110006483825.pdf 110006483825.pdf (905.1 kB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2012-09-28
タイトル
タイトル Experimental Model for Shear Stress Measurement in Vascular Circulation by Micro Particle Image Velocimetry
タイトル
言語 en
タイトル Experimental Model for Shear Stress Measurement in Vascular Circulation by Micro Particle Image Velocimetry
言語
言語 eng
キーワード
主題Scheme Other
主題 flow visualization
キーワード
主題Scheme Other
主題 micro PIV
キーワード
主題Scheme Other
主題 microcirculation
キーワード
主題Scheme Other
主題 shear stress
キーワード
主題Scheme Other
主題 liver transplantation
キーワード
主題Scheme Other
主題 velocity measurement
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
著者 Sato, Yoshinobu

× Sato, Yoshinobu

WEKO 51673

Sato, Yoshinobu

Search repository
Fujisawa, Nobuyuki

× Fujisawa, Nobuyuki

WEKO 51674

Fujisawa, Nobuyuki

Search repository
Hatakeyama, Katsuyoshi

× Hatakeyama, Katsuyoshi

WEKO 51675

Hatakeyama, Katsuyoshi

Search repository
抄録
内容記述タイプ Abstract
内容記述 The present study investigated the basic architectonics of a micro particle image velocimetry (PIV) system and measured shear stress in a model of hepatic microcirculation for the purpose of understanding mechanical stress in small-for-size graft liver transplantation. The flow velocity was measured using a micro PIV system in a straight confluence, with bifurcation channels of the hepatic sinusoid model made of a clear acrylics that was 300μm in width and 100μm in height. In the micro PIV system, two strobes as a light source illuminated an object from underneath, and its visual flow images were recorded into a computer using a high-resolution CCD camera. The flow visualization was performed by adding distilled water to proper nylon tracer particles of 1μm in diameter (specific gravity: 1.02). The experimental velocity profile measured by this micro PIV system was in good accordance with both the results obtained using the three-dimensional Navier-Strokes equations on a square tube and Hagen-Poiseulle equations on a circular tube, which confirmed the suitability of this measurement system. The flow velocity after both confluence and branching in the model of hepatic circulation very rapidly became similar to that of the straight flow. The wall shear stress was calculated using an equation of τ=μ・du/dy, based on the measured mean velocity distribution. The measurement data of shear stress in the straight flow was accurate with an error of 6%. This micro PIV system had sufficient reliability for measuring the shear stress in hepatic microcirculation and serve as a new instrument for understanding pathological conditions in hepatic microcirculation in small-for-size liver transplantation.
書誌情報 Acta medica et biologica
en : Acta medica et biologica

巻 54, 号 3, p. 77-83, 発行日 2006-09
出版者
出版者 Niigata University School of Medicine
ISSN
収録物識別子タイプ ISSN
収録物識別子 05677734
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AA00508361
権利
権利情報 本文データは学協会の許諾に基づきCiNiiから複製したものである
著者版フラグ
値 publisher
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 19:43:42.252109
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3