Cup implantation accuracy using the HipCOMPASS mechanical intraoperative support device.

http://hdl.handle.net/10191/50419
http://hdl.handle.net/10191/50419
41839f99-9956-4cf5-b2b3-6b8dc710386d
名前 / ファイル ライセンス アクション
h29nmk813.pdf 本文 (1.6 MB)
h29nmk813_a.pdf 要旨 (592.8 kB)
Item type 学位論文 / Thesis or Dissertation(1)
公開日 2018-07-26
タイトル
タイトル Cup implantation accuracy using the HipCOMPASS mechanical intraoperative support device.
タイトル
タイトル Cup implantation accuracy using the HipCOMPASS mechanical intraoperative support device.
言語 en
言語
言語 eng
資源タイプ
資源 http://purl.org/coar/resource_type/c_46ec
タイプ thesis
その他のタイトル
その他のタイトル 機械式術中支援デバイスHip COMPASSを使用したCup設置精度
著者 Suda, Ken

× Suda, Ken

WEKO 51248

Suda, Ken

Search repository
著者別名
識別子Scheme WEKO
識別子 51249
姓名 須田, 健
抄録
内容記述タイプ Abstract
内容記述 Background: While navigation systems have been developed to increase implantation accuracy in total hip arthroplasty (THA), they are not yet sufficiently versatile or commonly used. Therefore, to elevate the appeal of such systems, we have developed HipCOMPASS, a simple and effective mechanical angle indicator for use in supine THA. Questions/purposes: How accurate is the mean cup orientation [in terms of errors in radiographic anteversion (RA) and inclination (RI)] in cases where HipCOMPASS is used for intraoperative support? Does HipCOMPASS increase this cup orientation accuracy compared to THA cases without it? Does HipCOMPASS increase mean operation time? Methods: We measured cup orientation in 97 THA cases with HipCOMPASS and in 80 cases without it. Then we compared the angles determined in preoperative planning with the angles revealed by postoperative computed tomography (CT) for both groups. The discrepancy between them was defined as an error. Errors greater than 10° were considered outliers. Additionally, mean operative time with and without the Hip COMPASS were compared. Results: With the use of HipCOMPASS, the mean absolute error values in radiographic anteversion and inclination were 2.9° ± 2.3° (range 0°–12.8°) and 2.9° ± 2.1° (0.1°–7.7°), respectively. In contrast, without the use of HipCOMPASS, radiographic anteversion and inclination error values were 8.8° ± 5.8° (0.1°–25.4°) and 6.1° ± 4.5° (0.2°–21.0°), respectively. Outlier occurrence rates were 1.0 % with HipCOMPASS and 48.8 % without it. Mean operative times with and without HipCOMPASS use were 109.2 ± 23.8 min (74–199 min) and 137.6 ± 40.6 min (71–298 min), respectively. Conclusions: The study has found that HipCOMPASS dramatically increases implantation accuracy and it is also a simple and highly versatile tool that can be implemented quickly. Given its low cost in addition to its favourable accuracy, simple implementation, and short operative time, HipCOMPASS can be regarded as a very useful and effective THA support device.
内容記述
内容記述タイプ Other
内容記述 学位の種類: 博士(医学). 報告番号: 甲第4414号. 学位記番号: 新大院博(医)甲第813号. 学位授与年月日: 平成30年3月23日
内容記述
内容記述タイプ Other
内容記述 SpringerPlus. 2016. 5:784.
内容記述
内容記述タイプ Other
内容記述 1
内容記述
内容記述タイプ Other
内容記述 8
書誌情報 発行日 2018-03-23
出版者
出版者 新潟大学
DOI
識別子タイプ DOI
関連識別子 info:doi/10.1186/s40064-016-2503-z
著者版フラグ
値 ETD
学位名
学位名 博士(医学)
学位授与機関
学位授与機関名 新潟大学
学位授与年月日
学位授与年月日 2018-03-23
学位授与番号
学位授与番号 13101甲第4414号
学位記番号
内容記述タイプ Other
内容記述 新大院博(医)甲第813号
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 08:40:33.486390
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

Suda, Ken, 2018, Cup implantation accuracy using the HipCOMPASS mechanical intraoperative support device.: 新潟大学.

Loading...

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3