WEKO3
アイテム
{"_buckets": {"deposit": "c941fa5b-d2a9-43dd-aaea-e3bece14e4f0"}, "_deposit": {"id": "5590", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "5590"}, "status": "published"}, "_oai": {"id": "oai:niigata-u.repo.nii.ac.jp:00005590", "sets": ["455", "564"]}, "item_6_alternative_title_1": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "エレクトロスピニング法により作製した高分子ファイバーを利用したロングレンジ表面プラズモン共鳴バイオセンサーに関する研究"}]}, "item_6_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2015-03-23", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "85", "bibliographicPageStart": "1", "bibliographic_titles": [{}]}]}, "item_6_date_granted_51": {"attribute_name": "学位授与年月日", "attribute_value_mlt": [{"subitem_dategranted": "2015-03-23"}]}, "item_6_degree_grantor_49": {"attribute_name": "学位授与機関", "attribute_value_mlt": [{"subitem_degreegrantor": [{"subitem_degreegrantor_name": "新潟大学"}]}]}, "item_6_degree_name_48": {"attribute_name": "学位名", "attribute_value_mlt": [{"subitem_degreename": "博士(工学)"}]}, "item_6_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The fabrication of long-range surface plasmon resonance (LR-SPR) immunosensor from water-stable electrospun polyacrylic acid (PAA) fibers was studied. LR-SPR setup consists of thin gold film and layer of Cytop which let it has larger evanescent field intensity and penetration depth. The water-stable electrospun PAA fibers produced by adding β-cyclodextrin as crosslinker followed by thermal treatment at 180 °C for 40 min were fabricated onto the LR-SPR sensor surface. The free carboxyl group of electrospun PAA fibers was activated to immobilize antibody-antigen in immunosensor application. The layer-by-layer (LbL) system on the electrospun PAA fibers was performed to further increase water-stability of fibers and number of active carboxyl group. Therefore, the LR-SPR immunosensor based on water-stable electrospun PAA fibers was used to detect of human immunoglobulin G (IgG).", "subitem_description_type": "Abstract"}]}, "item_6_description_5": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "学位の種類: 博士(工学). 報告番号: 甲第4045号. 学位記番号: 新大院博(工)甲第427号. 学位授与年月日: 平成27年3月23日", "subitem_description_type": "Other"}]}, "item_6_description_53": {"attribute_name": "学位記番号", "attribute_value_mlt": [{"subitem_description": "新大院博(工)甲第427号", "subitem_description_type": "Other"}]}, "item_6_dissertation_number_52": {"attribute_name": "学位授与番号", "attribute_value_mlt": [{"subitem_dissertationnumber": "13101甲第4045号"}]}, "item_6_publisher_7": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "新潟大学"}]}, "item_6_select_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "ETD"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Netsuwan, Paphawadee"}], "nameIdentifiers": [{"nameIdentifier": "50550", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-08-05"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "h26ftk427.pdf", "filesize": [{"value": "3.0 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 3000000.0, "url": {"label": "本文", "url": "https://niigata-u.repo.nii.ac.jp/record/5590/files/h26ftk427.pdf"}, "version_id": "d877771a-5549-4a32-ae1f-b0f6347117d2"}, {"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-08-05"}], "displaytype": "detail", "download_preview_message": "", "file_order": 1, "filename": "h26ftk427_a.pdf", "filesize": [{"value": "161.9 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 161900.0, "url": {"label": "要旨", "url": "https://niigata-u.repo.nii.ac.jp/record/5590/files/h26ftk427_a.pdf"}, "version_id": "0bf27130-e98d-46c2-972f-34f6f9ac10cb"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "thesis", "resourceuri": "http://purl.org/coar/resource_type/c_46ec"}]}, "item_title": "Study on Long-range Surface Plasmon Resonance Biosensor Using Electrospun Polymer Fibers", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Study on Long-range Surface Plasmon Resonance Biosensor Using Electrospun Polymer Fibers"}, {"subitem_title": "Study on Long-range Surface Plasmon Resonance Biosensor Using Electrospun Polymer Fibers", "subitem_title_language": "en"}]}, "item_type_id": "6", "owner": "1", "path": ["455", "564"], "permalink_uri": "http://hdl.handle.net/10191/32208", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-05-29"}, "publish_date": "2015-05-29", "publish_status": "0", "recid": "5590", "relation": {}, "relation_version_is_last": true, "title": ["Study on Long-range Surface Plasmon Resonance Biosensor Using Electrospun Polymer Fibers"], "weko_shared_id": 2}
Study on Long-range Surface Plasmon Resonance Biosensor Using Electrospun Polymer Fibers
http://hdl.handle.net/10191/32208
http://hdl.handle.net/10191/32208bb874da6-875a-4612-b96d-96e94e8920a5
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
|
![]() |
|
Item type | 学位論文 / Thesis or Dissertation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-05-29 | |||||
タイトル | ||||||
タイトル | Study on Long-range Surface Plasmon Resonance Biosensor Using Electrospun Polymer Fibers | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Study on Long-range Surface Plasmon Resonance Biosensor Using Electrospun Polymer Fibers | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_46ec | |||||
タイプ | thesis | |||||
その他のタイトル | ||||||
その他のタイトル | エレクトロスピニング法により作製した高分子ファイバーを利用したロングレンジ表面プラズモン共鳴バイオセンサーに関する研究 | |||||
著者 |
Netsuwan, Paphawadee
× Netsuwan, Paphawadee |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The fabrication of long-range surface plasmon resonance (LR-SPR) immunosensor from water-stable electrospun polyacrylic acid (PAA) fibers was studied. LR-SPR setup consists of thin gold film and layer of Cytop which let it has larger evanescent field intensity and penetration depth. The water-stable electrospun PAA fibers produced by adding β-cyclodextrin as crosslinker followed by thermal treatment at 180 °C for 40 min were fabricated onto the LR-SPR sensor surface. The free carboxyl group of electrospun PAA fibers was activated to immobilize antibody-antigen in immunosensor application. The layer-by-layer (LbL) system on the electrospun PAA fibers was performed to further increase water-stability of fibers and number of active carboxyl group. Therefore, the LR-SPR immunosensor based on water-stable electrospun PAA fibers was used to detect of human immunoglobulin G (IgG). | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 学位の種類: 博士(工学). 報告番号: 甲第4045号. 学位記番号: 新大院博(工)甲第427号. 学位授与年月日: 平成27年3月23日 | |||||
書誌情報 | p. 1-85, 発行日 2015-03-23 | |||||
出版者 | ||||||
出版者 | 新潟大学 | |||||
著者版フラグ | ||||||
値 | ETD | |||||
学位名 | ||||||
学位名 | 博士(工学) | |||||
学位授与機関 | ||||||
学位授与機関名 | 新潟大学 | |||||
学位授与年月日 | ||||||
学位授与年月日 | 2015-03-23 | |||||
学位授与番号 | ||||||
学位授与番号 | 13101甲第4045号 | |||||
学位記番号 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 新大院博(工)甲第427号 |