WEKO3
アイテム
{"_buckets": {"deposit": "53043820-dbe1-47a6-9b21-37b8ba822e76"}, "_deposit": {"id": "33921", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "33921"}, "status": "published"}, "_oai": {"id": "oai:niigata-u.repo.nii.ac.jp:00033921", "sets": ["455", "562"]}, "item_6_alternative_title_1": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "健常者における様々な肢位での手指屈筋腱と橈骨遠位部との最小距離に関する研究"}]}, "item_6_date_granted_51": {"attribute_name": "学位授与年月日", "attribute_value_mlt": [{"subitem_dategranted": "2019-09-20"}]}, "item_6_degree_grantor_49": {"attribute_name": "学位授与機関", "attribute_value_mlt": [{"subitem_degreegrantor": [{"subitem_degreegrantor_name": "新潟大学"}]}]}, "item_6_degree_name_48": {"attribute_name": "学位名", "attribute_value_mlt": [{"subitem_degreename": "博士(医学)"}]}, "item_6_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Purpose: Rupture of the flexor pollicis longus (FPL) and index flexor digitorum profundus (FDP2) tendons often occurs after locking plate fixation for distal radius fracture. This study aimed to determine the shortest tendon-radius distances of different hand positions. Methods: Fifty-nine hands of 30 healthy volunteers were studied. Distances between the FPL or FDP2 and distal radius were calculated in six wrist positions: 30° palmar flexion, neutral, 30° dorsiflexion, 60° dorsiflexion, maximum dorsiflexion, and 40° ulnar deviation with three finger positions (full extension and flexion of fingers, full flexion of the thumb or index finger, and full extension of the other four fingers). The shortest distance between the FPL or FDP2 and distal radius was noted. Results: The shortest distance between the FPL and distal radius was during maximum wrist dorsiflexion with isolated thumb flexion. The distance between the FDP2 and distal radius was shortest with all-finger flexion in 30° wrist dorsiflexion. Conclusions: It is necessary to measure the distance between the FPL and distal radius in maximal wrist dorsiflexion with full flexion of the isolated thumb, as the shortest distance was observed with flexion of the isolated thumb. On the contrary, we recommend measuring the distance between the FDP2 and distal radius in 30° wrist dorsiflexion with flexion of all fingers.", "subitem_description_type": "Abstract"}]}, "item_6_description_5": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "Journal of Medical Ultrasonics. 2019, 46(3), 353–359.", "subitem_description_type": "Other"}]}, "item_6_description_53": {"attribute_name": "学位記番号", "attribute_value_mlt": [{"subitem_description": "新大院博(医)甲第898号", "subitem_description_type": "Other"}]}, "item_6_dissertation_number_52": {"attribute_name": "学位授与番号", "attribute_value_mlt": [{"subitem_dissertationnumber": "13101甲第4638号"}]}, "item_6_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "177886", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "今尾, 貫太"}]}]}, "item_6_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "info:doi/10.1007/s10396-019-00935-5", "subitem_relation_type_select": "DOI"}}]}, "item_6_rights_15": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "【○!C】 The Japan Society of Ultrasonics in Medicine 2019"}]}, "item_6_select_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "ETD"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Imao, Kanta"}], "nameIdentifiers": [{"nameIdentifier": "177885", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-07-08"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "r1nmk898.pdf", "filesize": [{"value": "1.0 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1000000.0, "url": {"label": "本文", "url": "https://niigata-u.repo.nii.ac.jp/record/33921/files/r1nmk898.pdf"}, "version_id": "6d551015-0f6d-436e-8bfc-d49845f326da"}, {"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2020-07-08"}], "displaytype": "detail", "download_preview_message": "", "file_order": 1, "filename": "r1nmk898_a.pdf", "filesize": [{"value": "483.7 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 483700.0, "url": {"label": "要旨", "url": "https://niigata-u.repo.nii.ac.jp/record/33921/files/r1nmk898_a.pdf"}, "version_id": "c24e15ad-7ab7-4341-9a40-78f63ae37246"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Distal radius", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Flexor pollicis longus", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Index fexor digitorum profundus", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Ultrasound", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "thesis", "resourceuri": "http://purl.org/coar/resource_type/c_46ec"}]}, "item_title": "Investigating the minimum distance between the finger flexor tendons and distal radius during wrist and finger positions in healthy people", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Investigating the minimum distance between the finger flexor tendons and distal radius during wrist and finger positions in healthy people"}]}, "item_type_id": "6", "owner": "1", "path": ["455", "562"], "permalink_uri": "http://hdl.handle.net/10191/00051719", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-07-08"}, "publish_date": "2020-07-08", "publish_status": "0", "recid": "33921", "relation": {}, "relation_version_is_last": true, "title": ["Investigating the minimum distance between the finger flexor tendons and distal radius during wrist and finger positions in healthy people"], "weko_shared_id": null}
Investigating the minimum distance between the finger flexor tendons and distal radius during wrist and finger positions in healthy people
http://hdl.handle.net/10191/00051719
http://hdl.handle.net/10191/0005171907997969-25ff-4bcb-8577-b3c404b422a2
名前 / ファイル | ライセンス | アクション |
---|---|---|
本文 (1.0 MB)
|
|
|
要旨 (483.7 kB)
|
|
Item type | 学位論文 / Thesis or Dissertation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-07-08 | |||||
タイトル | ||||||
タイトル | Investigating the minimum distance between the finger flexor tendons and distal radius during wrist and finger positions in healthy people | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Distal radius | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Flexor pollicis longus | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Index fexor digitorum profundus | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Ultrasound | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_46ec | |||||
タイプ | thesis | |||||
その他のタイトル | ||||||
その他のタイトル | 健常者における様々な肢位での手指屈筋腱と橈骨遠位部との最小距離に関する研究 | |||||
著者 |
Imao, Kanta
× Imao, Kanta |
|||||
著者別名 | ||||||
識別子 | 177886 | |||||
識別子Scheme | WEKO | |||||
姓名 | 今尾, 貫太 | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Purpose: Rupture of the flexor pollicis longus (FPL) and index flexor digitorum profundus (FDP2) tendons often occurs after locking plate fixation for distal radius fracture. This study aimed to determine the shortest tendon-radius distances of different hand positions. Methods: Fifty-nine hands of 30 healthy volunteers were studied. Distances between the FPL or FDP2 and distal radius were calculated in six wrist positions: 30° palmar flexion, neutral, 30° dorsiflexion, 60° dorsiflexion, maximum dorsiflexion, and 40° ulnar deviation with three finger positions (full extension and flexion of fingers, full flexion of the thumb or index finger, and full extension of the other four fingers). The shortest distance between the FPL or FDP2 and distal radius was noted. Results: The shortest distance between the FPL and distal radius was during maximum wrist dorsiflexion with isolated thumb flexion. The distance between the FDP2 and distal radius was shortest with all-finger flexion in 30° wrist dorsiflexion. Conclusions: It is necessary to measure the distance between the FPL and distal radius in maximal wrist dorsiflexion with full flexion of the isolated thumb, as the shortest distance was observed with flexion of the isolated thumb. On the contrary, we recommend measuring the distance between the FDP2 and distal radius in 30° wrist dorsiflexion with flexion of all fingers. | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | Journal of Medical Ultrasonics. 2019, 46(3), 353–359. | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | info:doi/10.1007/s10396-019-00935-5 | |||||
権利 | ||||||
権利情報 | 【○!C】 The Japan Society of Ultrasonics in Medicine 2019 | |||||
著者版フラグ | ||||||
値 | ETD | |||||
学位名 | ||||||
学位名 | 博士(医学) | |||||
学位授与機関 | ||||||
学位授与機関名 | 新潟大学 | |||||
学位授与年月日 | ||||||
学位授与年月日 | 2019-09-20 | |||||
学位授与番号 | ||||||
学位授与番号 | 13101甲第4638号 | |||||
学位記番号 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 新大院博(医)甲第898号 |