WEKO3
アイテム
{"_buckets": {"deposit": "493ab656-29d7-4d91-af86-7ddc800e2278"}, "_deposit": {"id": "31081", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "31081"}, "status": "published"}, "_oai": {"id": "oai:niigata-u.repo.nii.ac.jp:00031081", "sets": ["457", "436"]}, "item_8_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2005", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "6", "bibliographicPageStart": "1", "bibliographicVolumeNumber": "2005", "bibliographic_titles": [{"bibliographic_title": "Proceedings of the First International Conference on Complex Medical Engineering"}, {"bibliographic_title": "Proceedings of the First International Conference on Complex Medical Engineering", "bibliographic_titleLang": "en"}]}]}, "item_8_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Liver cirrhosis is a diagnosis based on histological concept. However, liver biopsy, sampling liver tissues from a living donor, is an invasive technique, in which a direct puncture of the liver is necessary. On the other hand, a higher resolution of a recent computed tomography has a potential to replace histology with objective and digital images, which are available without any invasive techniques. Here we present a system extracting various features of three-dimensional vasculature in the liver from images of CT aiming an objective and noninvasive diagnosis of liver cirrhosis.", "subitem_description_type": "Abstract"}]}, "item_8_select_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "author"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Ishikawa, M."}], "nameIdentifiers": [{"nameIdentifier": "169569", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Uchida, H."}], "nameIdentifiers": [{"nameIdentifier": "169570", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tamaki, T."}], "nameIdentifiers": [{"nameIdentifier": "169571", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamamoto, M."}], "nameIdentifiers": [{"nameIdentifier": "169572", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Suda, T."}], "nameIdentifiers": [{"nameIdentifier": "169573", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Igarashi, M."}], "nameIdentifiers": [{"nameIdentifier": "169574", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Aoyagi, Y."}], "nameIdentifiers": [{"nameIdentifier": "169575", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-08-26"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "CME2005_1-6.pdf", "filesize": [{"value": "220.7 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 220700.0, "url": {"label": "CME2005_1-6.pdf", "url": "https://niigata-u.repo.nii.ac.jp/record/31081/files/CME2005_1-6.pdf"}, "version_id": "f9137d3f-87a3-4c2a-860d-03c7610791ef"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Computer aided diagnosis", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Liver cirrhosis", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Computed Tomography", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "Method to Extract Various Vascular Features from Liver Images of Computed Tomography", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Method to Extract Various Vascular Features from Liver Images of Computed Tomography"}, {"subitem_title": "Method to Extract Various Vascular Features from Liver Images of Computed Tomography", "subitem_title_language": "en"}]}, "item_type_id": "8", "owner": "1", "path": ["457", "436"], "permalink_uri": "http://hdl.handle.net/10191/25762", "pubdate": {"attribute_name": "公開日", "attribute_value": "2014-02-25"}, "publish_date": "2014-02-25", "publish_status": "0", "recid": "31081", "relation": {}, "relation_version_is_last": true, "title": ["Method to Extract Various Vascular Features from Liver Images of Computed Tomography"], "weko_shared_id": null}
Method to Extract Various Vascular Features from Liver Images of Computed Tomography
http://hdl.handle.net/10191/25762
http://hdl.handle.net/10191/25762b90276be-9ebb-45cc-bd38-e32b7f8ba12a
名前 / ファイル | ライセンス | アクション |
---|---|---|
CME2005_1-6.pdf (220.7 kB)
|
|
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2014-02-25 | |||||
タイトル | ||||||
タイトル | Method to Extract Various Vascular Features from Liver Images of Computed Tomography | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Method to Extract Various Vascular Features from Liver Images of Computed Tomography | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Computer aided diagnosis | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Liver cirrhosis | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Computed Tomography | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_5794 | |||||
タイプ | conference paper | |||||
著者 |
Ishikawa, M.
× Ishikawa, M.× Uchida, H.× Tamaki, T.× Yamamoto, M.× Suda, T.× Igarashi, M.× Aoyagi, Y. |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Liver cirrhosis is a diagnosis based on histological concept. However, liver biopsy, sampling liver tissues from a living donor, is an invasive technique, in which a direct puncture of the liver is necessary. On the other hand, a higher resolution of a recent computed tomography has a potential to replace histology with objective and digital images, which are available without any invasive techniques. Here we present a system extracting various features of three-dimensional vasculature in the liver from images of CT aiming an objective and noninvasive diagnosis of liver cirrhosis. | |||||
書誌情報 |
Proceedings of the First International Conference on Complex Medical Engineering en : Proceedings of the First International Conference on Complex Medical Engineering 巻 2005, p. 1-6, 発行日 2005 |
|||||
著者版フラグ | ||||||
値 | author |