{"_buckets": {"deposit": "d33e6519-7553-4536-9212-39bdb5452279"}, "_deposit": {"id": "3102", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "3102"}, "status": "published"}, "_oai": {"id": "oai:niigata-u.repo.nii.ac.jp:00003102", "sets": ["454", "425"]}, "item_5_alternative_title_1": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Optical Telemeter System of Strain-gauge Output in Rotating Object"}]}, "item_5_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2004-08", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "8", "bibliographicPageEnd": "1105", "bibliographicPageStart": "1101", "bibliographicVolumeNumber": "70", "bibliographic_titles": [{"bibliographic_title": "精密工学会誌論文集"}, {"bibliographic_title": "精密工学会誌論文集", "bibliographic_titleLang": "en"}]}]}, "item_5_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "This paper deals with the optical telemeter system of strain-gauge output in rotating object. Bridge circuit composed of strain-gauges is connected to an amplifier and the output of amplifier is A/D converted according to the control series generated by a one-chip micro-controller, and the A/D result of serial data series is fed to LED on rotating object and sent as the optical data series. The optical data series is received by PD on stationary head, and the serial PD output is converted to parallel datum and inputted to personal computer. Tensile force acting on the sensing plate based upon the centrifugal force due to the spindle rotation is measured by the strain-gauge and the optical telemeter system. Theoretical tensile force is calculated. It is confirmed that the measured force coincides well with the theoretical force. This system has the function of quick-input of known-strain.", "subitem_description_type": "Abstract"}]}, "item_5_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "40818", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Yokoyama, Kazuhiro"}]}, {"nameIdentifiers": [{"nameIdentifier": "40819", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Sato, Masanori"}]}, {"nameIdentifiers": [{"nameIdentifier": "39", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Suzuki, Takamasa"}]}]}, "item_5_publisher_7": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "精密工学会"}]}, "item_5_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "info:doi/10.2493/jspe.70.1101", "subitem_relation_type_select": "DOI"}}]}, "item_5_relation_31": {"attribute_name": "異版である", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://ci.nii.ac.jp/naid/110001824041", "subitem_relation_type_select": "URI"}}]}, "item_5_rights_15": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "© 2004 精密工学会"}, {"subitem_rights": "本文データは学協会の許諾に基づきCiNiiから複製したものである"}]}, "item_5_select_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_5_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA11966630", "subitem_source_identifier_type": "NCID"}]}, "item_5_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "13488724", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "横山, 和宏"}], "nameIdentifiers": [{"nameIdentifier": "40815", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐藤, 正範"}], "nameIdentifiers": [{"nameIdentifier": "40816", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鈴木, 孝昌"}], "nameIdentifiers": [{"nameIdentifier": "39", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-07-30"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "110001824041.pdf", "filesize": [{"value": "547.7 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 547700.0, "url": {"label": "110001824041.pdf", "url": "https://niigata-u.repo.nii.ac.jp/record/3102/files/110001824041.pdf"}, "version_id": "8bffc6ca-6abc-44d9-ab4f-5574fd96fd13"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "optical telemeter system", "subitem_subject_scheme": "Other"}, {"subitem_subject": "strain-gauge output", "subitem_subject_scheme": "Other"}, {"subitem_subject": "rotating object", "subitem_subject_scheme": "Other"}, {"subitem_subject": "A/D conversion", "subitem_subject_scheme": "Other"}, {"subitem_subject": "LED", "subitem_subject_scheme": "Other"}, {"subitem_subject": "PD", "subitem_subject_scheme": "Other"}, {"subitem_subject": "personal computer", "subitem_subject_scheme": "Other"}, {"subitem_subject": "tensile force", "subitem_subject_scheme": "Other"}, {"subitem_subject": "centrifugal force", "subitem_subject_scheme": "Other"}, {"subitem_subject": "known-strain", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "回転体におけるひずみゲージ出力の光テレメータリング", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "回転体におけるひずみゲージ出力の光テレメータリング"}, {"subitem_title": "回転体におけるひずみゲージ出力の光テレメータリング", "subitem_title_language": "en"}]}, "item_type_id": "5", "owner": "1", "path": ["454", "425"], "permalink_uri": "http://hdl.handle.net/10191/27604", "pubdate": {"attribute_name": "公開日", "attribute_value": "2014-06-20"}, "publish_date": "2014-06-20", "publish_status": "0", "recid": "3102", "relation": {}, "relation_version_is_last": true, "title": ["回転体におけるひずみゲージ出力の光テレメータリング"], "weko_shared_id": null}
回転体におけるひずみゲージ出力の光テレメータリング
http://hdl.handle.net/10191/27604
http://hdl.handle.net/10191/276048661bd3e-3564-4cd1-b0a6-9bc0ed30fe8e
名前 / ファイル | ライセンス | アクション |
---|---|---|
110001824041.pdf (547.7 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2014-06-20 | |||||
タイトル | ||||||
タイトル | 回転体におけるひずみゲージ出力の光テレメータリング | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | 回転体におけるひずみゲージ出力の光テレメータリング | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | optical telemeter system | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | strain-gauge output | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | rotating object | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | A/D conversion | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | LED | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | PD | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | personal computer | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | tensile force | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | centrifugal force | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | known-strain | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
その他のタイトル | ||||||
その他のタイトル | Optical Telemeter System of Strain-gauge Output in Rotating Object | |||||
著者 |
横山, 和宏
× 横山, 和宏× 佐藤, 正範× 鈴木, 孝昌 |
|||||
著者別名 | ||||||
識別子 | 40818 | |||||
識別子Scheme | WEKO | |||||
姓名 | Yokoyama, Kazuhiro | |||||
著者別名 | ||||||
識別子 | 40819 | |||||
識別子Scheme | WEKO | |||||
姓名 | Sato, Masanori | |||||
著者別名 | ||||||
識別子 | 39 | |||||
識別子Scheme | WEKO | |||||
姓名 | Suzuki, Takamasa | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | This paper deals with the optical telemeter system of strain-gauge output in rotating object. Bridge circuit composed of strain-gauges is connected to an amplifier and the output of amplifier is A/D converted according to the control series generated by a one-chip micro-controller, and the A/D result of serial data series is fed to LED on rotating object and sent as the optical data series. The optical data series is received by PD on stationary head, and the serial PD output is converted to parallel datum and inputted to personal computer. Tensile force acting on the sensing plate based upon the centrifugal force due to the spindle rotation is measured by the strain-gauge and the optical telemeter system. Theoretical tensile force is calculated. It is confirmed that the measured force coincides well with the theoretical force. This system has the function of quick-input of known-strain. | |||||
書誌情報 |
精密工学会誌論文集 en : 精密工学会誌論文集 巻 70, 号 8, p. 1101-1105, 発行日 2004-08 |
|||||
出版者 | ||||||
出版者 | 精密工学会 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 13488724 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA11966630 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | info:doi/10.2493/jspe.70.1101 | |||||
権利 | ||||||
権利情報 | © 2004 精密工学会 | |||||
権利 | ||||||
権利情報 | 本文データは学協会の許諾に基づきCiNiiから複製したものである | |||||
著者版フラグ | ||||||
値 | publisher | |||||
異版である | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | URI | |||||
関連識別子 | http://ci.nii.ac.jp/naid/110001824041 |