Accuracy Veriffication of Image-Matching in a Setting Method for the Stem during Total Hip Arthroplasty

http://hdl.handle.net/10191/26371
http://hdl.handle.net/10191/26371
53aa7467-11a8-4314-9651-07addb3ab39f
名前 / ファイル ライセンス アクション
10_SP_247-250.pdf 10_SP_247-250.pdf (1.2 MB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2014-03-17
タイトル
タイトル Accuracy Veriffication of Image-Matching in a Setting Method for the Stem during Total Hip Arthroplasty
タイトル
タイトル Accuracy Veriffication of Image-Matching in a Setting Method for the Stem during Total Hip Arthroplasty
言語 en
言語
言語 eng
キーワード
主題Scheme Other
主題 Controlled Stem Setting Method
キーワード
主題Scheme Other
主題 Total Hip Arthroplasty
キーワード
主題Scheme Other
主題 Image-Matching
キーワード
主題Scheme Other
主題 Femoral Head
キーワード
主題Scheme Other
主題 Downhill Simplex Method
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ journal article
著者 Kubota, Yosuke

× Kubota, Yosuke

WEKO 40059

Kubota, Yosuke

Search repository
Sakamoto, Makoto

× Sakamoto, Makoto

WEKO 40060

Sakamoto, Makoto

Search repository
Kobayashi, Koichi

× Kobayashi, Koichi

WEKO 40061

Kobayashi, Koichi

Search repository
Koga, Yoshio

× Koga, Yoshio

WEKO 40062

Koga, Yoshio

Search repository
Tanabe, Yuji

× Tanabe, Yuji

WEKO 40063

Tanabe, Yuji

Search repository
抄録
内容記述タイプ Abstract
内容記述 Currently, stem insertion during total hip arthroplasty (THA) is not well controlled. The present study investigated a method for improving stem setting in accordance with preoperative planning using a three-dimensional (3-D) computed tomography (CT) model of the femur and RGB images of the excised femoral head. We utilized three femoral heads removed during THA and modeled each head using three spherical acrylic markers. Each femoral head was osteotomized using a parallel jig and three rectangular images of the osteotomized head were taken using a CCD camera. Each femoral head was then set on a camera base and RGB images were taken from three orthogonal directions using the CCD camera. The B-images of the femoral head and the 3-D bone model were processed through image-matching software using an automatic outline extraction and downhill simplex method. The position of the contralateral side of the jig, related to the femur, was measured using a 3-D measuring system in order to validate the accuracy of the image-matching. However, since validation of the accuracy of the image-matching is difficult once the femoral head is excised, a six-degree-of-freedom board was used to facilitate the accuracy validation.
書誌情報 実験力学
en : 実験力学

巻 10, 号 Special Issue, p. 247-250, 発行日 2010-08
出版者
出版者 日本実験力学会
ISSN
収録物識別子タイプ ISSN
収録物識別子 13464930
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AA11822914
権利
権利情報 Copyright (C) 2010 JSEM
権利
権利情報 コンテンツのご利用は著作権法の範囲内でお願いします。
権利
権利情報 本文データは学協会の許諾に基づきJ-Stageから複製したものである
著者版フラグ
値 publisher
異版である
関連タイプ isVersionOf
識別子タイプ URI
関連識別子 https://www.jstage.jst.go.jp/article/jjsem/10/Special_Issue/10_Special_Issue_s247/_pdf
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 20:20:44.915430
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3