ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "656c8c24-5f56-43f6-8473-598e5ba97d09"}, "_deposit": {"id": "2748", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "2748"}, "status": "published"}, "_oai": {"id": "oai:niigata-u.repo.nii.ac.jp:00002748", "sets": ["454", "425"]}, "item_5_alternative_title_1": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "A Computerized Analysis System of Masticatory Electromyograph with Silent Period"}]}, "item_5_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1983-04", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "99", "bibliographicPageStart": "93", "bibliographicVolumeNumber": "21", "bibliographic_titles": [{"bibliographic_title": "医用電子と生体工学"}, {"bibliographic_title": "医用電子と生体工学", "bibliographic_titleLang": "en"}]}]}, "item_5_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A computerized analysis system for the masticatory muscles has been developed. Silent period (SP), which observed in masticatory muscles shortly after the tooth contact during tapping movements or after chin tap during clenching, has been determined of its diagnostic value for TMJ dysfunction.\\nThis system has the following characteristics; 1) applicable for a dental clinic, 2) automated objective measurements of the SP parameters, and 3) easy data processing for statistical analyses. In order to measure the SP parameters, threshold level technique and peak to peak technique are common. However, since these techniques have some disadvantages, a new technique, “activity changing curve” has been developed. This parameter is independent of the amplitude of the EMG and shows marked increase at the onset or the termination of the SP. Thus it indicates the SP parameters more clearly and more objectively than the other methods. We are proposing a four muscles and four divisions coordination pattern analysis, which shows a status of the masticatory function by means of durations and integrated values of the masticatory muscles and a stochastic analysis, which shows constitution of the SP by means and standard deviations of the EMG signal at each time. As the results of this systematic analyses for clinical examination of many subjects, the patients with TMJ dysfunction showed significantly variation of SP duration etc. This clinical application has proved the efficiency of this system.", "subitem_description_type": "Abstract"}]}, "item_5_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "38855", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Kiryu, Tohru"}]}, {"nameIdentifiers": [{"nameIdentifier": "38856", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Saitoh, Yoshiaki"}]}, {"nameIdentifiers": [{"nameIdentifier": "38857", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Yamaga, Takuo"}]}, {"nameIdentifiers": [{"nameIdentifier": "38858", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Ishioka, Kiyoshi"}]}]}, "item_5_publisher_7": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本ME学会"}]}, "item_5_select_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_5_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00016981", "subitem_source_identifier_type": "NCID"}]}, "item_5_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "00213292", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "木竜, 徹"}], "nameIdentifiers": [{"nameIdentifier": "38851", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "斎藤, 義明"}], "nameIdentifiers": [{"nameIdentifier": "38852", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山鹿, 卓郎"}], "nameIdentifiers": [{"nameIdentifier": "38853", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石岡, 靖"}], "nameIdentifiers": [{"nameIdentifier": "38854", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-07-29"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "21_2_93-99.pdf", "filesize": [{"value": "1.2 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1200000.0, "url": {"label": "21_2_93-99.pdf", "url": "https://niigata-u.repo.nii.ac.jp/record/2748/files/21_2_93-99.pdf"}, "version_id": "63a9d82f-767b-4d1d-9165-35305a009e3f"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Silent Period 分析による咀嚼筋筋電図自動解析システム", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Silent Period 分析による咀嚼筋筋電図自動解析システム"}, {"subitem_title": "Silent Period 分析による咀嚼筋筋電図自動解析システム", "subitem_title_language": "en"}]}, "item_type_id": "5", "owner": "1", "path": ["454", "425"], "permalink_uri": "http://hdl.handle.net/10191/20183", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-10-24"}, "publish_date": "2012-10-24", "publish_status": "0", "recid": "2748", "relation": {}, "relation_version_is_last": true, "title": ["Silent Period 分析による咀嚼筋筋電図自動解析システム"], "weko_shared_id": null}
  1. 060 工学部
  2. 10 学術雑誌論文
  3. 10 査読済論文
  1. 0 資料タイプ別
  2. 01 学術雑誌論文

Silent Period 分析による咀嚼筋筋電図自動解析システム

http://hdl.handle.net/10191/20183
http://hdl.handle.net/10191/20183
b8082d4f-1380-4354-b3fa-58d31cd54273
名前 / ファイル ライセンス アクション
21_2_93-99.pdf 21_2_93-99.pdf (1.2 MB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2012-10-24
タイトル
タイトル Silent Period 分析による咀嚼筋筋電図自動解析システム
タイトル
言語 en
タイトル Silent Period 分析による咀嚼筋筋電図自動解析システム
言語
言語 jpn
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ journal article
その他のタイトル
その他のタイトル A Computerized Analysis System of Masticatory Electromyograph with Silent Period
著者 木竜, 徹

× 木竜, 徹

WEKO 38851

木竜, 徹

Search repository
斎藤, 義明

× 斎藤, 義明

WEKO 38852

斎藤, 義明

Search repository
山鹿, 卓郎

× 山鹿, 卓郎

WEKO 38853

山鹿, 卓郎

Search repository
石岡, 靖

× 石岡, 靖

WEKO 38854

石岡, 靖

Search repository
著者別名
識別子 38855
識別子Scheme WEKO
姓名 Kiryu, Tohru
著者別名
識別子 38856
識別子Scheme WEKO
姓名 Saitoh, Yoshiaki
著者別名
識別子 38857
識別子Scheme WEKO
姓名 Yamaga, Takuo
著者別名
識別子 38858
識別子Scheme WEKO
姓名 Ishioka, Kiyoshi
抄録
内容記述タイプ Abstract
内容記述 A computerized analysis system for the masticatory muscles has been developed. Silent period (SP), which observed in masticatory muscles shortly after the tooth contact during tapping movements or after chin tap during clenching, has been determined of its diagnostic value for TMJ dysfunction.\nThis system has the following characteristics; 1) applicable for a dental clinic, 2) automated objective measurements of the SP parameters, and 3) easy data processing for statistical analyses. In order to measure the SP parameters, threshold level technique and peak to peak technique are common. However, since these techniques have some disadvantages, a new technique, “activity changing curve” has been developed. This parameter is independent of the amplitude of the EMG and shows marked increase at the onset or the termination of the SP. Thus it indicates the SP parameters more clearly and more objectively than the other methods. We are proposing a four muscles and four divisions coordination pattern analysis, which shows a status of the masticatory function by means of durations and integrated values of the masticatory muscles and a stochastic analysis, which shows constitution of the SP by means and standard deviations of the EMG signal at each time. As the results of this systematic analyses for clinical examination of many subjects, the patients with TMJ dysfunction showed significantly variation of SP duration etc. This clinical application has proved the efficiency of this system.
書誌情報 医用電子と生体工学
en : 医用電子と生体工学

巻 21, 号 2, p. 93-99, 発行日 1983-04
出版者
出版者 日本ME学会
ISSN
収録物識別子タイプ ISSN
収録物識別子 00213292
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN00016981
著者版フラグ
値 publisher
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 20:25:54.593003
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3