体外式汎用心臓ペースメーカの研究
http://hdl.handle.net/10191/25897
http://hdl.handle.net/10191/25897c409766d-f803-4985-959b-1f0c3bfc919f
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2014-02-28 | |||||
タイトル | ||||||
タイトル | 体外式汎用心臓ペースメーカの研究 | |||||
タイトル | ||||||
タイトル | 体外式汎用心臓ペースメーカの研究 | |||||
言語 | en | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
その他のタイトル | ||||||
その他のタイトル | External Type All-purpose Cardiac Pacemaker System | |||||
著者 |
牧野, 秀夫
× 牧野, 秀夫× 尾嵜, 真浩× 斉藤, 義明× 田村, 康二× 三田村, 好矩× 三上, 智久 |
|||||
著者別名 | ||||||
識別子Scheme | WEKO | |||||
識別子 | 38835 | |||||
姓名 | Makino, Hideo | |||||
著者別名 | ||||||
識別子Scheme | WEKO | |||||
識別子 | 38836 | |||||
姓名 | Ozaki, Masahiro | |||||
著者別名 | ||||||
識別子Scheme | WEKO | |||||
識別子 | 38837 | |||||
姓名 | Saitoh, Yoshiaki | |||||
著者別名 | ||||||
識別子Scheme | WEKO | |||||
識別子 | 38838 | |||||
姓名 | Tamura, Kohji | |||||
著者別名 | ||||||
識別子Scheme | WEKO | |||||
識別子 | 38839 | |||||
姓名 | Mitamura, Yoshinori | |||||
著者別名 | ||||||
識別子Scheme | WEKO | |||||
識別子 | 38840 | |||||
姓名 | Mikami, Tomohisa | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A microcomputer-based pacemaker system for evaluating the pacemaker treatment of arrhythmia is described. This system can function not only as a demand pacemaker but also as a pacemaker for tachycardia control as well as a defibrillator. All stimulations are delivered through a catheter electrode in the right ventricle and a subcutaneous electrode. For the detection of arrhythmia, ECG and blood pressure signals are used. In particular, the blood pressure signal is useful to detect the actual heart rate during burst pulse pacing which is capable of controlling ventricular tachycardia automatically. Moreover, during burst pulse pacing, special attention is paid to detecting hypotension in order not to cause ventricular fibrillation. Pacing failure is quickly sensed from variations in R-wave pulse amplitude and pulse width. When, after the heart has been stimulated, the ECG shows no response, and hypotension continues without any rhythmic contraction, a battery-operated defibrillator is triggered and defibrillation is accomplished automatically. This system has been designed using two 16Fbit microcomputers, one of which performs signal processing aria the other, output control. In animal experiments, examples of the use of the system for demand pacing, tachycardia termination, and defibrillation are given. This system may be used to study tachycardia termination and defibrillation in clinical laboratories. | |||||
書誌情報 |
医用電子と生体工学 en : 医用電子と生体工学 巻 23, 号 5, p. 299-305, 発行日 1985-09 |
|||||