{"_buckets": {"deposit": "469ed9d3-3fdf-4716-b1a1-30c775134d9d"}, "_deposit": {"id": "2739", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "2739"}, "status": "published"}, "_oai": {"id": "oai:niigata-u.repo.nii.ac.jp:00002739", "sets": ["454", "425"]}, "item_5_alternative_title_1": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Correction of Pressure Waveforms in a Catheter Manometer System by Natural Observation Method"}]}, "item_5_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1988-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "138", "bibliographicPageStart": "133", "bibliographicVolumeNumber": "26", "bibliographic_titles": [{"bibliographic_title": "医用電子と生体工学"}, {"bibliographic_title": "医用電子と生体工学", "bibliographic_titleLang": "en"}]}]}, "item_5_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Pressure waveforms obtained by catheter manometer systems are often distorted by resonance of catheter and so on. Corrections by Fourier analysis, low pass filter and digital signal proccessing have been reported, but they have never been put to practical use. We paid attention to the transfer function of catheter transducer systems and made a trial system that correct the distortion by natural observation method. This system increases the bandwidth in frequency domain and reduce the ringing in time domain. Advantages of this system are simple composition, a small number of adjusting points and real time performance without modifying the catheter or transducer. In an animal experiment, we corrected by our trial system the output waveforms recorded by a conventional catheter manometer system and compared these corrected output waveforms with catheter-tip manometer waveforms which are relatively distortionless. As a result, we could obtain less distorted pressure waveforms in left-ventricle and aorta and distinctly confirm dicrotic notch in aortic pressure waveforms.", "subitem_description_type": "Abstract"}]}, "item_5_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "38768", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Saitoh, Yoshiaki"}]}, {"nameIdentifiers": [{"nameIdentifier": "38769", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Hori, Jun-ichi"}]}, {"nameIdentifiers": [{"nameIdentifier": "38770", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Kiryu, Tohru"}]}, {"nameIdentifiers": [{"nameIdentifier": "38771", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Makino, Hideo"}]}, {"nameIdentifiers": [{"nameIdentifier": "38772", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Tamura, Kohji"}]}, {"nameIdentifiers": [{"nameIdentifier": "38773", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Yoshizaki, Tetsuyo"}]}, {"nameIdentifiers": [{"nameIdentifier": "38774", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Iijima, Taizo"}]}]}, "item_5_publisher_7": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本ME学会"}]}, "item_5_select_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_5_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00016981", "subitem_source_identifier_type": "NCID"}]}, "item_5_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "00213292", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "斉藤, 義明"}], "nameIdentifiers": [{"nameIdentifier": "38761", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "堀, 潤一"}], "nameIdentifiers": [{"nameIdentifier": "38762", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "木竜, 徹"}], "nameIdentifiers": [{"nameIdentifier": "38763", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "牧野, 秀夫"}], "nameIdentifiers": [{"nameIdentifier": "38764", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "田村, 康二"}], "nameIdentifiers": [{"nameIdentifier": "38765", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉崎, 哲世"}], "nameIdentifiers": [{"nameIdentifier": "38766", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "飯島, 泰蔵"}], "nameIdentifiers": [{"nameIdentifier": "38767", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-07-29"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "26_3_133-138.pdf", "filesize": [{"value": "771.6 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 771600.0, "url": {"label": "26_3_133-138.pdf", "url": "https://niigata-u.repo.nii.ac.jp/record/2739/files/26_3_133-138.pdf"}, "version_id": "eaa88f76-0cda-4551-84b6-e1a26399fd77"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "自然観測法によるカテーテル式血圧計の圧波形補正", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "自然観測法によるカテーテル式血圧計の圧波形補正"}, {"subitem_title": "自然観測法によるカテーテル式血圧計の圧波形補正", "subitem_title_language": "en"}]}, "item_type_id": "5", "owner": "1", "path": ["454", "425"], "permalink_uri": "http://hdl.handle.net/10191/20188", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-10-24"}, "publish_date": "2012-10-24", "publish_status": "0", "recid": "2739", "relation": {}, "relation_version_is_last": true, "title": ["自然観測法によるカテーテル式血圧計の圧波形補正"], "weko_shared_id": null}
  1. 060 工学部
  2. 10 学術雑誌論文
  3. 10 査読済論文
  1. 0 資料タイプ別
  2. 01 学術雑誌論文

自然観測法によるカテーテル式血圧計の圧波形補正

http://hdl.handle.net/10191/20188
http://hdl.handle.net/10191/20188
484a5675-e89e-4da5-b03f-8fd37d20ca49
名前 / ファイル ライセンス アクション
26_3_133-138.pdf 26_3_133-138.pdf (771.6 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2012-10-24
タイトル
タイトル 自然観測法によるカテーテル式血圧計の圧波形補正
タイトル
言語 en
タイトル 自然観測法によるカテーテル式血圧計の圧波形補正
言語
言語 jpn
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ journal article
その他のタイトル
その他のタイトル Correction of Pressure Waveforms in a Catheter Manometer System by Natural Observation Method
著者 斉藤, 義明

× 斉藤, 義明

WEKO 38761

斉藤, 義明

Search repository
堀, 潤一

× 堀, 潤一

WEKO 38762

堀, 潤一

Search repository
木竜, 徹

× 木竜, 徹

WEKO 38763

木竜, 徹

Search repository
牧野, 秀夫

× 牧野, 秀夫

WEKO 38764

牧野, 秀夫

Search repository
田村, 康二

× 田村, 康二

WEKO 38765

田村, 康二

Search repository
吉崎, 哲世

× 吉崎, 哲世

WEKO 38766

吉崎, 哲世

Search repository
飯島, 泰蔵

× 飯島, 泰蔵

WEKO 38767

飯島, 泰蔵

Search repository
著者別名
識別子 38768
識別子Scheme WEKO
姓名 Saitoh, Yoshiaki
著者別名
識別子 38769
識別子Scheme WEKO
姓名 Hori, Jun-ichi
著者別名
識別子 38770
識別子Scheme WEKO
姓名 Kiryu, Tohru
著者別名
識別子 38771
識別子Scheme WEKO
姓名 Makino, Hideo
著者別名
識別子 38772
識別子Scheme WEKO
姓名 Tamura, Kohji
著者別名
識別子 38773
識別子Scheme WEKO
姓名 Yoshizaki, Tetsuyo
著者別名
識別子 38774
識別子Scheme WEKO
姓名 Iijima, Taizo
抄録
内容記述タイプ Abstract
内容記述 Pressure waveforms obtained by catheter manometer systems are often distorted by resonance of catheter and so on. Corrections by Fourier analysis, low pass filter and digital signal proccessing have been reported, but they have never been put to practical use. We paid attention to the transfer function of catheter transducer systems and made a trial system that correct the distortion by natural observation method. This system increases the bandwidth in frequency domain and reduce the ringing in time domain. Advantages of this system are simple composition, a small number of adjusting points and real time performance without modifying the catheter or transducer. In an animal experiment, we corrected by our trial system the output waveforms recorded by a conventional catheter manometer system and compared these corrected output waveforms with catheter-tip manometer waveforms which are relatively distortionless. As a result, we could obtain less distorted pressure waveforms in left-ventricle and aorta and distinctly confirm dicrotic notch in aortic pressure waveforms.
書誌情報 医用電子と生体工学
en : 医用電子と生体工学

巻 26, 号 3, p. 133-138, 発行日 1988-09
出版者
出版者 日本ME学会
ISSN
収録物識別子タイプ ISSN
収録物識別子 00213292
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN00016981
著者版フラグ
値 publisher
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 20:26:08.571247
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3