WEKO3
AND
アイテム
{"_buckets": {"deposit": "d657cd98-7247-4726-8bc5-05442948bb13"}, "_deposit": {"id": "2735", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "2735"}, "status": "published"}, "_oai": {"id": "oai:niigata-u.repo.nii.ac.jp:00002735"}, "item_5_alternative_title_1": {"attribute_name": "\u305d\u306e\u4ed6\u306e\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_alternative_title": "Development of Unaware Detection System for Respiration and Heart Beats Using a Magnetic Sensor"}]}, "item_5_biblio_info_6": {"attribute_name": "\u66f8\u8a8c\u60c5\u5831", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2000-06", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "110", "bibliographicPageStart": "102", "bibliographicVolumeNumber": "38", "bibliographic_titles": [{"bibliographic_title": "\u533b\u7528\u96fb\u5b50\u3068\u751f\u4f53\u5de5\u5b66"}, {"bibliographic_title": "\u533b\u7528\u96fb\u5b50\u3068\u751f\u4f53\u5de5\u5b66", "bibliographic_titleLang": "en"}]}]}, "item_5_description_4": {"attribute_name": "\u6284\u9332", "attribute_value_mlt": [{"subitem_description": "Various vital sensors have been developed for patient monitoring. These sensors restrict patients physically or mentally since either electrodes or probes must be mounted onto a patient\u0027s body and then connected to a measuring instrument using a lead wire. In this study, a biomedical-signal detection system capable of being used without subject awareness on the basis of terrestrial magnetism was developed for home use and remote care. When a subject lies on a bed mattress that is situated on a magnetic sheet, the system detects the change in magnetic field related to respiration and heart beat. We have also developed an on-line system that can separate respiration and heart beat components from the detected signal.", "subitem_description_type": "Abstract"}]}, "item_5_full_name_3": {"attribute_name": "\u8457\u8005\u5225\u540d", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "38718", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Saitoh, Yoshiaki"}]}, {"nameIdentifiers": [{"nameIdentifier": "38719", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Hori, Jun-ichi"}]}, {"nameIdentifiers": [{"nameIdentifier": "38720", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Kiryu, Tohru"}]}]}, "item_5_publisher_7": {"attribute_name": "\u51fa\u7248\u8005", "attribute_value_mlt": [{"subitem_publisher": "\u65e5\u672cME\u5b66\u4f1a"}]}, "item_5_select_19": {"attribute_name": "\u8457\u8005\u7248\u30d5\u30e9\u30b0", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_5_source_id_11": {"attribute_name": "\u66f8\u8a8c\u30ec\u30b3\u30fc\u30c9ID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00016981", "subitem_source_identifier_type": "NCID"}]}, "item_5_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "00213292", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "\u8457\u8005", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "\u6589\u85e4, \u7fa9\u660e"}], "nameIdentifiers": [{"nameIdentifier": "38715", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u5800, \u6f64\u4e00"}], "nameIdentifiers": [{"nameIdentifier": "38716", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u6728\u7adc, \u5fb9"}], "nameIdentifiers": [{"nameIdentifier": "38717", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "\u30d5\u30a1\u30a4\u30eb\u60c5\u5831", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-07-29"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "38_2_102-110.pdf", "filesize": [{"value": "2.4 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 2400000.0, "url": {"label": "38_2_102-110.pdf", "url": "https://niigata-u.repo.nii.ac.jp/record/2735/files/38_2_102-110.pdf"}, "version_id": "0f157bff-8ed2-4521-8661-566fa077a072"}]}, "item_language": {"attribute_name": "\u8a00\u8a9e", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "\u78c1\u6c17\u30bb\u30f3\u30b5\u3092\u7528\u3044\u305f\u7121\u610f\u8b58\u547c\u5438\u5fc3\u62cd\u52d5\u691c\u51fa\u88c5\u7f6e\u306e\u958b\u767a", "item_titles": {"attribute_name": "\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_title": "\u78c1\u6c17\u30bb\u30f3\u30b5\u3092\u7528\u3044\u305f\u7121\u610f\u8b58\u547c\u5438\u5fc3\u62cd\u52d5\u691c\u51fa\u88c5\u7f6e\u306e\u958b\u767a"}, {"subitem_title": "\u78c1\u6c17\u30bb\u30f3\u30b5\u3092\u7528\u3044\u305f\u7121\u610f\u8b58\u547c\u5438\u5fc3\u62cd\u52d5\u691c\u51fa\u88c5\u7f6e\u306e\u958b\u767a", "subitem_title_language": "en"}]}, "item_type_id": "5", "owner": "1", "path": ["453/454", "468/469/470"], "permalink_uri": "http://hdl.handle.net/10191/20190", "pubdate": {"attribute_name": "\u516c\u958b\u65e5", "attribute_value": "2012-10-24"}, "publish_date": "2012-10-24", "publish_status": "0", "recid": "2735", "relation": {}, "relation_version_is_last": true, "title": ["\u78c1\u6c17\u30bb\u30f3\u30b5\u3092\u7528\u3044\u305f\u7121\u610f\u8b58\u547c\u5438\u5fc3\u62cd\u52d5\u691c\u51fa\u88c5\u7f6e\u306e\u958b\u767a"], "weko_shared_id": null}
磁気センサを用いた無意識呼吸心拍動検出装置の開発
http://hdl.handle.net/10191/20190
d4b24089-9a2f-4aa4-a25e-4b0b1bdd09cc
名前 / ファイル | ライセンス | アクション | |
---|---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2012-10-24 | |||||
タイトル | ||||||
タイトル | 磁気センサを用いた無意識呼吸心拍動検出装置の開発 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | 磁気センサを用いた無意識呼吸心拍動検出装置の開発 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
その他のタイトル | ||||||
その他のタイトル | Development of Unaware Detection System for Respiration and Heart Beats Using a Magnetic Sensor | |||||
著者 |
斉藤, 義明
× 斉藤, 義明× 堀, 潤一× 木竜, 徹 |
|||||
著者別名 | ||||||
識別子 | ||||||
識別子 | 38718 | |||||
識別子Scheme | WEKO | |||||
姓名 | ||||||
姓名 | Saitoh, Yoshiaki | |||||
著者別名 | ||||||
識別子 | ||||||
識別子 | 38719 | |||||
識別子Scheme | WEKO | |||||
姓名 | ||||||
姓名 | Hori, Jun-ichi | |||||
著者別名 | ||||||
識別子 | ||||||
識別子 | 38720 | |||||
識別子Scheme | WEKO | |||||
姓名 | ||||||
姓名 | Kiryu, Tohru | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Various vital sensors have been developed for patient monitoring. These sensors restrict patients physically or mentally since either electrodes or probes must be mounted onto a patient's body and then connected to a measuring instrument using a lead wire. In this study, a biomedical-signal detection system capable of being used without subject awareness on the basis of terrestrial magnetism was developed for home use and remote care. When a subject lies on a bed mattress that is situated on a magnetic sheet, the system detects the change in magnetic field related to respiration and heart beat. We have also developed an on-line system that can separate respiration and heart beat components from the detected signal. | |||||
書誌情報 |
医用電子と生体工学 en : 医用電子と生体工学 巻 38, 号 2, p. 102-110, 発行日 2000-06 |
|||||
出版者 | ||||||
出版者 | 日本ME学会 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 00213292 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00016981 | |||||
著者版フラグ | ||||||
値 | publisher |