ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "e94fea64-6cc5-487a-a8d0-50008f565148"}, "_deposit": {"id": "24232", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "24232"}, "status": "published"}, "_oai": {"id": "oai:niigata-u.repo.nii.ac.jp:00024232", "sets": ["456", "1236"]}, "item_7_alternative_title_1": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Red Blood Cell Transfusion for Anemic Patients (Indications and Problems in Tranfusion of Blood Components as of 1986)"}]}, "item_7_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1987-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "157", "bibliographicPageStart": "152", "bibliographicVolumeNumber": "101", "bibliographic_titles": [{"bibliographic_title": "新潟医学会雑誌"}, {"bibliographic_title": "新潟医学会雑誌", "bibliographic_titleLang": "en"}]}]}, "item_7_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Blood components used in Niigata Universithy Hospital for the past 10 years were analyzed. Approximately, 14,000±1,000 units of red cell components were transfused anually, whereas units of fresh frozen plasma (plasma) increased markedly year by year. Blood components and their numbers used for patients in medical clinics from April 1985 to March 1986 were studied. Ten out of 74 leukemic patients were transfused only red Cell (mean; 10.9 units), and 38 cases were transfused red cell (mean; 25.2 units), platelet (mean; 401.5 units) and plasma (mean; 34.2 units). Eight out of 14 patients with aplastic anemia were transfused only red cell (mean; 14.5 units), and 5 cases were transfused red cell (mean; 49.8 units), platelet (mean; 386.4 units) and plasma (mean; 14.2 units). Of 26 cases with renal insufficiency, 20 with hepatic carcinoma and 12 with lung cancer, only red cell components were transfused in 20 cases (mean; 4.9 units), 4 cases (mean; 9.0 units) and 7 cases (mean; 7.3 units), respectively. Packed red cell components were passed through a depth type blood filter, Sepacell, manufactured in Asahi Medical Co.,Ltd. The numbers of leukocyte and platelet in the filted blood were negligible. Scanning electromicrographs of post-filtered membrane showed numerous adhesions of those cells. In conclusion, we should use packed red cell more for anemic patients who need to be transfused 1 to 2 units daily. On multiple red cell transfusions, using of filtered red components is recommended so that we can avoid hazadous reaction due to contaminated blood cells other than red cell.", "subitem_description_type": "Abstract"}]}, "item_7_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "144999", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Shinada, Shoji"}]}, {"nameIdentifiers": [{"nameIdentifier": "145000", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Kojima, Hideo"}]}, {"nameIdentifiers": [{"nameIdentifier": "145001", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Soga, Norishige"}]}, {"nameIdentifiers": [{"nameIdentifier": "145002", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Shibata, Akira"}]}]}, "item_7_publisher_7": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "新潟医学会"}]}, "item_7_select_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_7_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00182415", "subitem_source_identifier_type": "NCID"}]}, "item_7_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "00290440", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "品田, 章二"}], "nameIdentifiers": [{"nameIdentifier": "144995", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小島, 秀男"}], "nameIdentifiers": [{"nameIdentifier": "144996", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "曽我, 謙臣"}], "nameIdentifiers": [{"nameIdentifier": "144997", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "柴田, 昭"}], "nameIdentifiers": [{"nameIdentifier": "144998", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-08-19"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "101(3)_152-157.pdf", "filesize": [{"value": "1.5 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1500000.0, "url": {"label": "101(3)_152-157.pdf", "url": "https://niigata-u.repo.nii.ac.jp/record/24232/files/101(3)_152-157.pdf"}, "version_id": "0619c6fd-e126-4711-9194-8f2492db4829"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "blood components", "subitem_subject_scheme": "Other"}, {"subitem_subject": "filtered red cell", "subitem_subject_scheme": "Other"}, {"subitem_subject": "plasma", "subitem_subject_scheme": "Other"}, {"subitem_subject": "platelets", "subitem_subject_scheme": "Other"}, {"subitem_subject": "blood filter", "subitem_subject_scheme": "Other"}, {"subitem_subject": "multiple transfusion", "subitem_subject_scheme": "Other"}, {"subitem_subject": "血液成分", "subitem_subject_scheme": "Other"}, {"subitem_subject": "濾過赤血球", "subitem_subject_scheme": "Other"}, {"subitem_subject": "血漿", "subitem_subject_scheme": "Other"}, {"subitem_subject": "血小板", "subitem_subject_scheme": "Other"}, {"subitem_subject": "血液フィルター", "subitem_subject_scheme": "Other"}, {"subitem_subject": "頻回輸血", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "1) 『貧血患者への赤血球輸血について』(シンポジウム 血液製剤の輸血適応と問題点, 1986年, 第420回新潟医学会例会)", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "1) 『貧血患者への赤血球輸血について』(シンポジウム 血液製剤の輸血適応と問題点, 1986年, 第420回新潟医学会例会)"}, {"subitem_title": "1) 『貧血患者への赤血球輸血について』(シンポジウム 血液製剤の輸血適応と問題点, 1986年, 第420回新潟医学会例会)", "subitem_title_language": "en"}]}, "item_type_id": "7", "owner": "1", "path": ["456", "1236"], "permalink_uri": "http://hdl.handle.net/10191/36376", "pubdate": {"attribute_name": "公開日", "attribute_value": "2016-01-07"}, "publish_date": "2016-01-07", "publish_status": "0", "recid": "24232", "relation": {}, "relation_version_is_last": true, "title": ["1) 『貧血患者への赤血球輸血について』(シンポジウム 血液製剤の輸血適応と問題点, 1986年, 第420回新潟医学会例会)"], "weko_shared_id": null}
  1. 0 資料タイプ別
  2. 03 紀要論文
  1. 250 大学院医歯学総合研究科(医)
  2. 20 紀要
  3. 02 新潟医学会雑誌
  4. 第101巻第3号

1) 『貧血患者への赤血球輸血について』(シンポジウム 血液製剤の輸血適応と問題点, 1986年, 第420回新潟医学会例会)

http://hdl.handle.net/10191/36376
http://hdl.handle.net/10191/36376
a7759350-376a-4e31-9cbf-642e2cb166cb
名前 / ファイル ライセンス アクション
101(3)_152-157.pdf 101(3)_152-157.pdf (1.5 MB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2016-01-07
タイトル
タイトル 1) 『貧血患者への赤血球輸血について』(シンポジウム 血液製剤の輸血適応と問題点, 1986年, 第420回新潟医学会例会)
タイトル
言語 en
タイトル 1) 『貧血患者への赤血球輸血について』(シンポジウム 血液製剤の輸血適応と問題点, 1986年, 第420回新潟医学会例会)
言語
言語 jpn
キーワード
主題Scheme Other
主題 blood components
キーワード
主題Scheme Other
主題 filtered red cell
キーワード
主題Scheme Other
主題 plasma
キーワード
主題Scheme Other
主題 platelets
キーワード
主題Scheme Other
主題 blood filter
キーワード
主題Scheme Other
主題 multiple transfusion
キーワード
主題Scheme Other
主題 血液成分
キーワード
主題Scheme Other
主題 濾過赤血球
キーワード
主題Scheme Other
主題 血漿
キーワード
主題Scheme Other
主題 血小板
キーワード
主題Scheme Other
主題 血液フィルター
キーワード
主題Scheme Other
主題 頻回輸血
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
その他のタイトル
その他のタイトル Red Blood Cell Transfusion for Anemic Patients (Indications and Problems in Tranfusion of Blood Components as of 1986)
著者 品田, 章二

× 品田, 章二

WEKO 144995

品田, 章二

Search repository
小島, 秀男

× 小島, 秀男

WEKO 144996

小島, 秀男

Search repository
曽我, 謙臣

× 曽我, 謙臣

WEKO 144997

曽我, 謙臣

Search repository
柴田, 昭

× 柴田, 昭

WEKO 144998

柴田, 昭

Search repository
著者別名
識別子 144999
識別子Scheme WEKO
姓名 Shinada, Shoji
著者別名
識別子 145000
識別子Scheme WEKO
姓名 Kojima, Hideo
著者別名
識別子 145001
識別子Scheme WEKO
姓名 Soga, Norishige
著者別名
識別子 145002
識別子Scheme WEKO
姓名 Shibata, Akira
抄録
内容記述タイプ Abstract
内容記述 Blood components used in Niigata Universithy Hospital for the past 10 years were analyzed. Approximately, 14,000±1,000 units of red cell components were transfused anually, whereas units of fresh frozen plasma (plasma) increased markedly year by year. Blood components and their numbers used for patients in medical clinics from April 1985 to March 1986 were studied. Ten out of 74 leukemic patients were transfused only red Cell (mean; 10.9 units), and 38 cases were transfused red cell (mean; 25.2 units), platelet (mean; 401.5 units) and plasma (mean; 34.2 units). Eight out of 14 patients with aplastic anemia were transfused only red cell (mean; 14.5 units), and 5 cases were transfused red cell (mean; 49.8 units), platelet (mean; 386.4 units) and plasma (mean; 14.2 units). Of 26 cases with renal insufficiency, 20 with hepatic carcinoma and 12 with lung cancer, only red cell components were transfused in 20 cases (mean; 4.9 units), 4 cases (mean; 9.0 units) and 7 cases (mean; 7.3 units), respectively. Packed red cell components were passed through a depth type blood filter, Sepacell, manufactured in Asahi Medical Co.,Ltd. The numbers of leukocyte and platelet in the filted blood were negligible. Scanning electromicrographs of post-filtered membrane showed numerous adhesions of those cells. In conclusion, we should use packed red cell more for anemic patients who need to be transfused 1 to 2 units daily. On multiple red cell transfusions, using of filtered red components is recommended so that we can avoid hazadous reaction due to contaminated blood cells other than red cell.
書誌情報 新潟医学会雑誌
en : 新潟医学会雑誌

巻 101, 号 3, p. 152-157, 発行日 1987-03
出版者
出版者 新潟医学会
ISSN
収録物識別子タイプ ISSN
収録物識別子 00290440
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN00182415
著者版フラグ
値 publisher
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 12:37:04.862348
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3