WEKO3
アイテム
{"_buckets": {"deposit": "a75c8549-c41a-47cd-bd30-b95ac42ba9cc"}, "_deposit": {"id": "22916", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "22916"}, "status": "published"}, "_oai": {"id": "oai:niigata-u.repo.nii.ac.jp:00022916", "sets": ["456", "1210"]}, "item_7_alternative_title_1": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Computer-Based Analysis of Alternate Pronation and Supination of Forearms"}]}, "item_7_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1989-05", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "5", "bibliographicPageEnd": "431", "bibliographicPageStart": "419", "bibliographicVolumeNumber": "103", "bibliographic_titles": [{"bibliographic_title": "新潟医学会雑誌"}, {"bibliographic_title": "新潟医学会雑誌", "bibliographic_titleLang": "en"}]}]}, "item_7_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A computer-based method for evaluating alternate pronation and supination of forearms (diadochokinesia test) has been developed. Forearm movements are converted into digital signals through a specially designed recording instrument. Tracings of movements are stored in a computer, and their rapidity and dexterity are quantified by ten parameters. An analysis was made by the method on the groups of healthy people and the patients with methylmercury poisoning, and significant differences were observed between the two groups. In all six parameters are defined as those related to dexterity. To establish a summary measure for dexterity, the principal component analysis was applied to the patient group, and the first principal component was adopted as the summary measure. The scores of the measure were compared with visual rankings given by five persons (four doctors and one secretary) for some sample tracings of movements, and close agreement was obtained between the measure and human judgment. As a final step of the study, a microcomputer-based device fully equipped to analyze diadochokinesia tests was implemented. The device has been made compact so that the test may be performed at the bedside and the tracings of the movements as well as the computed measurements are obtained immediately. The device will make the rapid quantitative analysis of diadochokinesia test possible in clinical practices.", "subitem_description_type": "Abstract"}]}, "item_7_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "138493", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Okada, Mihoko"}]}]}, "item_7_publisher_7": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "新潟医学会"}]}, "item_7_select_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_7_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00182415", "subitem_source_identifier_type": "NCID"}]}, "item_7_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "00290440", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "岡田, 美保子"}], "nameIdentifiers": [{"nameIdentifier": "138492", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-08-19"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "103(5)_419-431.pdf", "filesize": [{"value": "3.2 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 3200000.0, "url": {"label": "103(5)_419-431.pdf", "url": "https://niigata-u.repo.nii.ac.jp/record/22916/files/103(5)_419-431.pdf"}, "version_id": "542200c6-0c8d-4d09-ae80-da91e7178fbf"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Diadochokinesia test", "subitem_subject_scheme": "Other"}, {"subitem_subject": "computer analysis of forearm movements", "subitem_subject_scheme": "Other"}, {"subitem_subject": "pronation and supination of forearms", "subitem_subject_scheme": "Other"}, {"subitem_subject": "microcomputer based device", "subitem_subject_scheme": "Other"}, {"subitem_subject": "quantification of dexterity", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ディアドコキネージア テスト", "subitem_subject_scheme": "Other"}, {"subitem_subject": "前腕運動のコンピュータ分析", "subitem_subject_scheme": "Other"}, {"subitem_subject": "前腕の回内回外運動", "subitem_subject_scheme": "Other"}, {"subitem_subject": "マイクロコンピュータ内蔵型装置", "subitem_subject_scheme": "Other"}, {"subitem_subject": "巧緻性の定量化", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "両手変換運動試験の客観的評価に関する研究", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "両手変換運動試験の客観的評価に関する研究"}, {"subitem_title": "両手変換運動試験の客観的評価に関する研究", "subitem_title_language": "en"}]}, "item_type_id": "7", "owner": "1", "path": ["456", "1210"], "permalink_uri": "http://hdl.handle.net/10191/41257", "pubdate": {"attribute_name": "公開日", "attribute_value": "2016-04-11"}, "publish_date": "2016-04-11", "publish_status": "0", "recid": "22916", "relation": {}, "relation_version_is_last": true, "title": ["両手変換運動試験の客観的評価に関する研究"], "weko_shared_id": null}
両手変換運動試験の客観的評価に関する研究
http://hdl.handle.net/10191/41257
http://hdl.handle.net/10191/41257fdcf1bc4-275d-4a72-ba39-ed5db4200ed9
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-04-11 | |||||
タイトル | ||||||
タイトル | 両手変換運動試験の客観的評価に関する研究 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | 両手変換運動試験の客観的評価に関する研究 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Diadochokinesia test | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | computer analysis of forearm movements | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | pronation and supination of forearms | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | microcomputer based device | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | quantification of dexterity | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | ディアドコキネージア テスト | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 前腕運動のコンピュータ分析 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 前腕の回内回外運動 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | マイクロコンピュータ内蔵型装置 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 巧緻性の定量化 | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
その他のタイトル | ||||||
その他のタイトル | Computer-Based Analysis of Alternate Pronation and Supination of Forearms | |||||
著者 |
岡田, 美保子
× 岡田, 美保子 |
|||||
著者別名 | ||||||
識別子 | 138493 | |||||
識別子Scheme | WEKO | |||||
姓名 | Okada, Mihoko | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A computer-based method for evaluating alternate pronation and supination of forearms (diadochokinesia test) has been developed. Forearm movements are converted into digital signals through a specially designed recording instrument. Tracings of movements are stored in a computer, and their rapidity and dexterity are quantified by ten parameters. An analysis was made by the method on the groups of healthy people and the patients with methylmercury poisoning, and significant differences were observed between the two groups. In all six parameters are defined as those related to dexterity. To establish a summary measure for dexterity, the principal component analysis was applied to the patient group, and the first principal component was adopted as the summary measure. The scores of the measure were compared with visual rankings given by five persons (four doctors and one secretary) for some sample tracings of movements, and close agreement was obtained between the measure and human judgment. As a final step of the study, a microcomputer-based device fully equipped to analyze diadochokinesia tests was implemented. The device has been made compact so that the test may be performed at the bedside and the tracings of the movements as well as the computed measurements are obtained immediately. The device will make the rapid quantitative analysis of diadochokinesia test possible in clinical practices. | |||||
書誌情報 |
新潟医学会雑誌 en : 新潟医学会雑誌 巻 103, 号 5, p. 419-431, 発行日 1989-05 |
|||||
出版者 | ||||||
出版者 | 新潟医学会 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 00290440 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00182415 | |||||
著者版フラグ | ||||||
値 | publisher |