WEKO3
アイテム
3)ペースメーカー治療の進歩(シンポジウム 不整脈をめぐる諸問題, 第475回新潟医学会)
http://hdl.handle.net/10191/37331
http://hdl.handle.net/10191/3733111fc4f91-259e-41af-a05a-cde7fe9014ac
名前 / ファイル | ライセンス | アクション |
---|---|---|
107(4)_311-316.pdf (1.2 MB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-02-02 | |||||
タイトル | ||||||
タイトル | 3)ペースメーカー治療の進歩(シンポジウム 不整脈をめぐる諸問題, 第475回新潟医学会) | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | 3)ペースメーカー治療の進歩(シンポジウム 不整脈をめぐる諸問題, 第475回新潟医学会) | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | History | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Advancement | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Rate-responsive Pacemaker | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Dual-chamber Pacemaker | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Dual-chamber Rate-responsive Pacemaker | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 歴史 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 進歩 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | レート応答型ペースメーカー | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | デュアルチャンバーペースメーカー | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | デュアルチャンバーレート応答型ペースメーカー | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
その他のタイトル | ||||||
その他のタイトル | The Advancemant of Pacing Therapy(Current Topics on Cardiac Arrhythmias) | |||||
著者 |
桜井, 淑史
× 桜井, 淑史 |
|||||
著者別名 | ||||||
識別子 | 124934 | |||||
識別子Scheme | WEKO | |||||
姓名 | Sakurai, Yoshifumi | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Since the first implantable pacemaker (self-contained) was clinically used in U. S. A. in 1960, 31 years have passed, 29 years in Japan, and 26 years as far as my own clinical experience is concerned. During the course of history, pacemaker technology has advanced starting from VOO mode to VVI, AAI, VAT, VDD, DVI, DDI, DDD, VVIR, AAIR, DDDR(including DVIR, DDIR) mode in 1988. Over the past 26 years, many advancements and improvements have been made with the pacemaker. Pacemakers in the past were too large and heavy for Japanese patients. However, the size has been remarkably reduced and the smallest one has the size of a 500 yen coin. On the other hand, battery longevity for dual-chamber pacing and rate-responsive pacing seems to have decreased. The pacemaker system now has various additional functions such as telemetry, communication, and holter. These functions are very useful for the analysis of dual-chamber pacing and rate-responsive pacing. Physiologic pacing can be achieved through maintaining A-V synchrony and increasing the pacing rate. Rate-responsive pacing (AAIR, DDIR, DVIR, and DDDR) is designed to increase pacing rate with a dedicated sensor. | |||||
書誌情報 |
新潟医学会雑誌 en : 新潟医学会雑誌 巻 107, 号 4, p. 311-316, 発行日 1993-04 |
|||||
出版者 | ||||||
出版者 | 新潟医学会 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 00290440 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00182415 | |||||
著者版フラグ | ||||||
値 | publisher |