A new inlet system for microscale carbon and oxygen stable isotope analysis using dual inlet isotope ratio mass spectrometer at Niigata University, Japan

http://hdl.handle.net/10191/0002000226
http://hdl.handle.net/10191/0002000226
9763bd13-8a61-4f66-b4c2-23470543737f
名前 / ファイル ライセンス アクション
36_21-42.pdf 36_21-42.pdf (6.3 MB)
Item type 紀要論文 / Departmental Bulletin Paper(1)
公開日 2022-01-21
タイトル
タイトル A new inlet system for microscale carbon and oxygen stable isotope analysis using dual inlet isotope ratio mass spectrometer at Niigata University, Japan
言語 en
言語
言語 eng
キーワード
言語 en
主題Scheme Other
主題 carbon and oxygen isotopes
キーワード
言語 en
主題Scheme Other
主題 MAT-253 inlet system
キーワード
言語 en
主題Scheme Other
主題 NIST standard measurements
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ departmental bulletin paper
著者 Satish-Kumar, Madhusoodhan

× Satish-Kumar, Madhusoodhan

en Satish-Kumar, Madhusoodhan

Search repository
Kiran, Sasidharan

× Kiran, Sasidharan

en Kiran, Sasidharan

Search repository
Abe, Miyako

× Abe, Miyako

en Abe, Miyako

Search repository
抄録
内容記述タイプ Abstract
内容記述 A new Thermo Scientific^<TM> MAT-253 isotope ratio mass spectrometer was installed at Department of Geology, Niigata University, Japan under the MEXT Grant-in-Aid for Scientific Research on Innovative Areas. The mass spectrometer was set up for carbon and oxygen isotope measurement of small volume CO_2 samples. A new inlet vacuum line was constructed for transferring standard gas, to inlet externally prepared CO_2 gas samples and transfer CO_2 gas prepared in the online carbonate reaction system. The line is evacuated using a turbo molecular pump and pneumatically activated valves controlled by an electrical control board. The vacuum line also includes a reference CO_2 gas (Working Standard) reservoir and a laboratory standard CO_2 gas (Machine Standard) reservoir for routine analyses, as well as SF_6 reference gas reservoirs. The preparation line can hold high vacuum conditions without appreciable leaks for several hours, required for the completion of a single session of sample measurements. Long-term laboratory standard measurement results are reported here, which shows an average of δ^<13>C_<(V-PDB)> value of ‒29.796 ± 0.041‰ and δ^<18>O_<(V-SMOW)> value of 3.971 ± 0.062‰ (n = 44; 1σ). During a period of one year of analysis, a drift of 0.04‰ for both carbon and oxygen is observed for the reference CO_2 gas. NIST standards (NBS-20 limestone and NBS-21 graphite) and a laboratory diamond standard were analyzed to characterize the minimum volume of sample required to obtain carbon and oxygen isotopic composition with accuracy and precision <0.1‰. We also report here the routine analytical procedure for carbonate samples (calcite/aragonite and dolomite/siderite/magnesite) and elemental carbon (graphite and diamond).
言語 en
書誌情報 en : Science reports of Niigata University. (Geology)

巻 36, p. 21-42, 発行日 2021-03
出版者
出版者 Department of Geology, Faculty of Science, Niigata University
言語 en
ISSN
収録物識別子タイプ PISSN
収録物識別子 1349-1237
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AA11436808
出版タイプ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views

Versions

Ver.1 2022-01-21 06:51:39.617979
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3