WEKO3
アイテム
{"_buckets": {"deposit": "4a9a829d-e442-407f-ad08-587d8dc2193c"}, "_deposit": {"id": "2024", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "2024"}, "status": "published"}, "_oai": {"id": "oai:niigata-u.repo.nii.ac.jp:00002024", "sets": ["454", "425"]}, "author_link": ["6674", "6675", "6676", "6677", "6678", "6679", "6680"], "control_number": "2024", "item_1627363077551": {"attribute_name": "出版タイプ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_5_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2008-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "145", "bibliographicPageStart": "135", "bibliographicVolumeNumber": "3", "bibliographic_titles": [{"bibliographic_title": "Journal of Environment and Engineering", "bibliographic_titleLang": "en"}]}]}, "item_5_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "An air-cooling system of a small capacity of several kilo-watts using only water refrigerant as a non-CFCs (Chlorofluorocarbon) technology is examined. The experimental device consists of two stages. The first stage is composed of a vacuum pump and a vacuum chamber of about 60 L in volume. The second stage has two heat exchangers (the exchanger located outside the vacuum chamber is a dummy cooling load) and a water circulating pump. An air-conditioner indoor unit or a heater is used as a dummy cooling load. The temperature and humidity characteristics are measured at each place. Consequently, the ability to cool the room air is ensured by an air-cooling system using only water refrigerant. A new vacuum pump, that can exhaust a large amount of water vapor, is developed and its properties are measured. It seems that the engine-based vacuum pump performance is sufficient to drive the air cooling system with water refrigerant.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}]}, "item_5_publisher_7": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "The Japan Society of Mechanical Engineers", "subitem_publisher_language": "en"}]}, "item_5_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "http://doi.org/10.1299/jee.3.135", "subitem_relation_type_select": "DOI"}}]}, "item_5_relation_31": {"attribute_name": "異版である", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.jstage.jst.go.jp/browse/jee", "subitem_relation_type_select": "URI"}}]}, "item_5_rights_15": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "The Japan Society of Mechanical Engineers"}]}, "item_5_select_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "author"}]}, "item_5_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1880-988X", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Sugawara, Akira", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "6674", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakamikawa, Satoru", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "6675", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kageyama, Masaya", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "6676", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamazaki, Satoshi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "6677", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Abe, Naoto", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "6678", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kawasaki, Kazumasa", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "6679", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsubara, Koji", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "6680", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-07-29"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "3_1_135-145.pdf", "filesize": [{"value": "352.9 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 352900.0, "url": {"label": "3_1_135-145.pdf", "url": "https://niigata-u.repo.nii.ac.jp/record/2024/files/3_1_135-145.pdf"}, "version_id": "60c27229-74fb-44c6-825f-58689ea6ed2c"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Non-CFCs", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Air-cooling System", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Water", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Vacuum Pump", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Heat", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Research for Air Cooling System Using Vacuum-cooled Water Refrigerant", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Research for Air Cooling System Using Vacuum-cooled Water Refrigerant", "subitem_title_language": "en"}]}, "item_type_id": "5", "owner": "1", "path": ["454", "425"], "permalink_uri": "http://hdl.handle.net/10191/21866", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2013-04-18"}, "publish_date": "2013-04-18", "publish_status": "0", "recid": "2024", "relation": {}, "relation_version_is_last": true, "title": ["Research for Air Cooling System Using Vacuum-cooled Water Refrigerant"], "weko_shared_id": -1}
Research for Air Cooling System Using Vacuum-cooled Water Refrigerant
http://hdl.handle.net/10191/21866
http://hdl.handle.net/10191/218662be13e2a-25d4-47d2-a2c7-20f49520559d
名前 / ファイル | ライセンス | アクション |
---|---|---|
3_1_135-145.pdf (352.9 kB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2013-04-18 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Research for Air Cooling System Using Vacuum-cooled Water Refrigerant | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Non-CFCs | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Air-cooling System | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Water | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Vacuum Pump | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Heat | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
著者 |
Sugawara, Akira
× Sugawara, Akira× Nakamikawa, Satoru× Kageyama, Masaya× Yamazaki, Satoshi× Abe, Naoto× Kawasaki, Kazumasa× Matsubara, Koji |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | An air-cooling system of a small capacity of several kilo-watts using only water refrigerant as a non-CFCs (Chlorofluorocarbon) technology is examined. The experimental device consists of two stages. The first stage is composed of a vacuum pump and a vacuum chamber of about 60 L in volume. The second stage has two heat exchangers (the exchanger located outside the vacuum chamber is a dummy cooling load) and a water circulating pump. An air-conditioner indoor unit or a heater is used as a dummy cooling load. The temperature and humidity characteristics are measured at each place. Consequently, the ability to cool the room air is ensured by an air-cooling system using only water refrigerant. A new vacuum pump, that can exhaust a large amount of water vapor, is developed and its properties are measured. It seems that the engine-based vacuum pump performance is sufficient to drive the air cooling system with water refrigerant. | |||||
言語 | en | |||||
書誌情報 |
en : Journal of Environment and Engineering 巻 3, 号 1, p. 135-145, 発行日 2008-01 |
|||||
出版者 | ||||||
言語 | en | |||||
出版者 | The Japan Society of Mechanical Engineers | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1880-988X | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | http://doi.org/10.1299/jee.3.135 | |||||
権利 | ||||||
権利情報 | The Japan Society of Mechanical Engineers | |||||
出版タイプ | ||||||
出版タイプ | VoR | |||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |||||
著者版フラグ | ||||||
値 | author | |||||
異版である | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | URI | |||||
関連識別子 | https://www.jstage.jst.go.jp/browse/jee |