{"created":"2021-03-01T06:05:42.789002+00:00","id":2024,"links":{},"metadata":{"_buckets":{"deposit":"4a9a829d-e442-407f-ad08-587d8dc2193c"},"_deposit":{"id":"2024","owners":[],"pid":{"revision_id":0,"type":"depid","value":"2024"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00002024","sets":["423:424:425","453:454"]},"author_link":["6674","6675","6676","6677","6678","6679","6680"],"control_number":"2024","item_1627363077551":{"attribute_name":"出版タイプ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"145","bibliographicPageStart":"135","bibliographicVolumeNumber":"3","bibliographic_titles":[{"bibliographic_title":"Journal of Environment and Engineering","bibliographic_titleLang":"en"}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"An air-cooling system of a small capacity of several kilo-watts using only water refrigerant as a non-CFCs (Chlorofluorocarbon) technology is examined. The experimental device consists of two stages. The first stage is composed of a vacuum pump and a vacuum chamber of about 60 L in volume. The second stage has two heat exchangers (the exchanger located outside the vacuum chamber is a dummy cooling load) and a water circulating pump. An air-conditioner indoor unit or a heater is used as a dummy cooling load. The temperature and humidity characteristics are measured at each place. Consequently, the ability to cool the room air is ensured by an air-cooling system using only water refrigerant. A new vacuum pump, that can exhaust a large amount of water vapor, is developed and its properties are measured. It seems that the engine-based vacuum pump performance is sufficient to drive the air cooling system with water refrigerant.","subitem_description_language":"en","subitem_description_type":"Abstract"}]},"item_5_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"The Japan Society of Mechanical Engineers","subitem_publisher_language":"en"}]},"item_5_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://doi.org/10.1299/jee.3.135","subitem_relation_type_select":"DOI"}}]},"item_5_relation_31":{"attribute_name":"異版である","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.jstage.jst.go.jp/browse/jee","subitem_relation_type_select":"URI"}}]},"item_5_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"The Japan Society of Mechanical Engineers"}]},"item_5_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"author"}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1880-988X","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Sugawara, Akira","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"6674","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nakamikawa, Satoru","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"6675","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kageyama, Masaya","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"6676","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamazaki, Satoshi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"6677","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Abe, Naoto","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"6678","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kawasaki, Kazumasa","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"6679","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Matsubara, Koji","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"6680","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-07-29"}],"displaytype":"detail","filename":"3_1_135-145.pdf","filesize":[{"value":"352.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"3_1_135-145.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/2024/files/3_1_135-145.pdf"},"version_id":"60c27229-74fb-44c6-825f-58689ea6ed2c"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Non-CFCs","subitem_subject_scheme":"Other"},{"subitem_subject":"Air-cooling System","subitem_subject_scheme":"Other"},{"subitem_subject":"Water","subitem_subject_scheme":"Other"},{"subitem_subject":"Vacuum Pump","subitem_subject_scheme":"Other"},{"subitem_subject":"Heat","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Research for Air Cooling System Using Vacuum-cooled Water Refrigerant","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Research for Air Cooling System Using Vacuum-cooled Water Refrigerant","subitem_title_language":"en"}]},"item_type_id":"5","owner":"1","path":["454","425"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2013-04-18"},"publish_date":"2013-04-18","publish_status":"0","recid":"2024","relation_version_is_last":true,"title":["Research for Air Cooling System Using Vacuum-cooled Water Refrigerant"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2022-12-15T03:34:54.681923+00:00"}