WEKO3
アイテム
{"_buckets": {"deposit": "c191d751-18f1-41da-89d8-864e8a87da58"}, "_deposit": {"id": "10375", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "10375"}, "status": "published"}, "_oai": {"id": "oai:niigata-u.repo.nii.ac.jp:00010375", "sets": ["456", "966"]}, "item_7_alternative_title_1": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Biological Applications of Adiabatic Pulses on Magnetic Resonance Imaging"}]}, "item_7_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2010-06", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "6", "bibliographicPageEnd": "327", "bibliographicPageStart": "318", "bibliographicVolumeNumber": "124", "bibliographic_titles": [{"bibliographic_title": "新潟医学会雑誌"}, {"bibliographic_title": "新潟医学会雑誌", "bibliographic_titleLang": "en"}]}]}, "item_7_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "MRI装置の高磁場化による信号強度の増加は, MRI撮像にとって大きな利点となるが, 一方で, 高磁場化に伴いRF送信パワーが増加する. 加えて, マウスのような小動物の高空間分解能イメージングでは, 信号源となるボクセルのサイズが減少するため, 高いシグナルノイズ比を得るには, 依然として効率的な信号受信が必要となる. 高磁場測定におけるサーフェスコイルの利用は,その高いRF送信効率と優れた信号受信感度から, これらの問題を解決するために有効な方法となる. しかしながら, サーフェスコイルを送信コイルとして用いた場合, RF磁場が空間的に不均一となり, RF波のパフォーマンスが低下する. この不均一なRF磁場の影響は, フリップ角の大きなRF波に顕著であるため, 180度パルスを用いるT_1定量においては, 特に深刻な問題となる. 本研究では, 断熱パルスによりRF磁場不均一の影響を最小限に抑えることで, サーフェスコイル送受信による高磁場高速T_1定量法 time-optimized partial inversion recovery (TOPIR) の開発を行った. 一般に, T_1測定では, 撮像に長い時間を要することが大きな問題となるが, TOPIRでは, 緩和曲線のダイナミックレンジを確保しながら, 縦磁化緩和の待ち時間を解析的に最小化することで, 十分なT_1測定精度を維持しつつ, 最短時間での高速撮像を実現した. ファントム測定により測定精度の評価を行ったところ, TOPIRによるT_1測定の誤差は, IRと比べて4.0%以下に収まっており, TOPIRの妥当性が確認された. マウス脳測定においても, 20~36秒の撮像時間で, IRと遜色ないT_1定量を行うことが可能であった. 以上より, TOPIRは, サーフェスコイルを用いた動物実験において, 有用な高速T_1定量法である.", "subitem_description_type": "Abstract"}]}, "item_7_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "71136", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Kobayashi, Naoharu"}]}]}, "item_7_publisher_7": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "新潟医学会"}]}, "item_7_select_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_7_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00182415", "subitem_source_identifier_type": "NCID"}]}, "item_7_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "00290440", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "小林, 尚玄"}], "nameIdentifiers": [{"nameIdentifier": "71135", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-08-06"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "124(6)_318-327.pdf", "filesize": [{"value": "1.4 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1400000.0, "url": {"label": "124(6)_318-327.pdf", "url": "https://niigata-u.repo.nii.ac.jp/record/10375/files/124(6)_318-327.pdf"}, "version_id": "99e97579-1284-4afb-ae37-9d018be861a0"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "磁気共鳴影像法", "subitem_subject_scheme": "Other"}, {"subitem_subject": "縦緩和時間", "subitem_subject_scheme": "Other"}, {"subitem_subject": "断熱パルス", "subitem_subject_scheme": "Other"}, {"subitem_subject": "サーフェスコイル", "subitem_subject_scheme": "Other"}, {"subitem_subject": "MRI", "subitem_subject_scheme": "Other"}, {"subitem_subject": "T_1", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "磁気共鳴影像法における断熱パルスの生体応用", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "磁気共鳴影像法における断熱パルスの生体応用"}, {"subitem_title": "磁気共鳴影像法における断熱パルスの生体応用", "subitem_title_language": "en"}]}, "item_type_id": "7", "owner": "1", "path": ["456", "966"], "permalink_uri": "http://hdl.handle.net/10191/28769", "pubdate": {"attribute_name": "公開日", "attribute_value": "2014-07-24"}, "publish_date": "2014-07-24", "publish_status": "0", "recid": "10375", "relation": {}, "relation_version_is_last": true, "title": ["磁気共鳴影像法における断熱パルスの生体応用"], "weko_shared_id": null}
磁気共鳴影像法における断熱パルスの生体応用
http://hdl.handle.net/10191/28769
http://hdl.handle.net/10191/2876969e38e22-3005-4dba-b5a7-f2d6544b495d
名前 / ファイル | ライセンス | アクション |
---|---|---|
124(6)_318-327.pdf (1.4 MB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2014-07-24 | |||||
タイトル | ||||||
タイトル | 磁気共鳴影像法における断熱パルスの生体応用 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | 磁気共鳴影像法における断熱パルスの生体応用 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 磁気共鳴影像法 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 縦緩和時間 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 断熱パルス | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | サーフェスコイル | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | MRI | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | T_1 | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
その他のタイトル | ||||||
その他のタイトル | Biological Applications of Adiabatic Pulses on Magnetic Resonance Imaging | |||||
著者 |
小林, 尚玄
× 小林, 尚玄 |
|||||
著者別名 | ||||||
識別子 | 71136 | |||||
識別子Scheme | WEKO | |||||
姓名 | Kobayashi, Naoharu | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | MRI装置の高磁場化による信号強度の増加は, MRI撮像にとって大きな利点となるが, 一方で, 高磁場化に伴いRF送信パワーが増加する. 加えて, マウスのような小動物の高空間分解能イメージングでは, 信号源となるボクセルのサイズが減少するため, 高いシグナルノイズ比を得るには, 依然として効率的な信号受信が必要となる. 高磁場測定におけるサーフェスコイルの利用は,その高いRF送信効率と優れた信号受信感度から, これらの問題を解決するために有効な方法となる. しかしながら, サーフェスコイルを送信コイルとして用いた場合, RF磁場が空間的に不均一となり, RF波のパフォーマンスが低下する. この不均一なRF磁場の影響は, フリップ角の大きなRF波に顕著であるため, 180度パルスを用いるT_1定量においては, 特に深刻な問題となる. 本研究では, 断熱パルスによりRF磁場不均一の影響を最小限に抑えることで, サーフェスコイル送受信による高磁場高速T_1定量法 time-optimized partial inversion recovery (TOPIR) の開発を行った. 一般に, T_1測定では, 撮像に長い時間を要することが大きな問題となるが, TOPIRでは, 緩和曲線のダイナミックレンジを確保しながら, 縦磁化緩和の待ち時間を解析的に最小化することで, 十分なT_1測定精度を維持しつつ, 最短時間での高速撮像を実現した. ファントム測定により測定精度の評価を行ったところ, TOPIRによるT_1測定の誤差は, IRと比べて4.0%以下に収まっており, TOPIRの妥当性が確認された. マウス脳測定においても, 20~36秒の撮像時間で, IRと遜色ないT_1定量を行うことが可能であった. 以上より, TOPIRは, サーフェスコイルを用いた動物実験において, 有用な高速T_1定量法である. | |||||
書誌情報 |