{"created":"2021-03-01T06:10:28.844196+00:00","id":6568,"links":{},"metadata":{"_buckets":{"deposit":"1a2d6e07-bebe-426a-86fd-88e07038716e"},"_deposit":{"id":"6568","owners":[],"pid":{"revision_id":0,"type":"depid","value":"6568"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00006568","sets":["453:456","471:537:568:637"]},"item_7_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1992-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"27","bibliographicPageStart":"21","bibliographicVolumeNumber":"40","bibliographic_titles":[{"bibliographic_title":"Acta medica et biologica"},{"bibliographic_title":"Acta medica et biologica","bibliographic_titleLang":"en"}]}]},"item_7_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The rate-responsive ventricular pacing (VVIR) was evaluated by the comparison of responses of the sinus rate during exercise on a treadmill, between the VVIR mode and rate-fixed (VVI) mode as well as by the comparison of hemodynamic responses. The duration of exercise was increased with the VVIR pacing, and at low to moderate levels of exercise the sinus rate was significantly lower in the VVIR mode than in the VVI mode (p <0.01-0.05). Blood pressure remaind at a lower level and pulse pressure was smaller in the VVIR mode. The beneficial effects of the chronotropic responses of the VVIR mode were reflected in hemodynamic responses and response of the sinus rate.","subitem_description_type":"Abstract"}]},"item_7_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"Niigata University School of Medicine"}]},"item_7_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_7_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA00508361","subitem_source_identifier_type":"NCID"}]},"item_7_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"05677734","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Hirokawa, Yohichi"}],"nameIdentifiers":[{"nameIdentifier":"53516","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-08-06"}],"displaytype":"detail","filename":"40(1)_21-27.pdf","filesize":[{"value":"898.5 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"40(1)_21-27.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/6568/files/40(1)_21-27.pdf"},"version_id":"c774df23-04d1-47f1-9493-c7bd514ccd7c"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Chronotropic Responses to Exercise on Treadmill by Patients with Implanted Rate Responsive Pacemaker","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Chronotropic Responses to Exercise on Treadmill by Patients with Implanted Rate Responsive Pacemaker"},{"subitem_title":"Chronotropic Responses to Exercise on Treadmill by Patients with Implanted Rate Responsive Pacemaker","subitem_title_language":"en"}]},"item_type_id":"7","owner":"1","path":["456","637"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-09-18"},"publish_date":"2015-09-18","publish_status":"0","recid":"6568","relation_version_is_last":true,"title":["Chronotropic Responses to Exercise on Treadmill by Patients with Implanted Rate Responsive Pacemaker"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-15T03:39:54.819503+00:00"}