{"_buckets": {"deposit": "6325d2d3-0536-422f-bc76-b06e66c15299"}, "_deposit": {"id": "6489", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "6489"}, "status": "published"}, "_oai": {"id": "oai:niigata-u.repo.nii.ac.jp:00006489", "sets": ["456", "625"]}, "item_7_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1994-12", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "4", "bibliographicPageEnd": "169", "bibliographicPageStart": "165", "bibliographicVolumeNumber": "42", "bibliographic_titles": [{"bibliographic_title": "Acta medica et biologica"}, {"bibliographic_title": "Acta medica et biologica", "bibliographic_titleLang": "en"}]}]}, "item_7_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Liver function was examined in 60 patients with a 0.1 and 0.5 mg/kg intravenous bolus of indocyanine green (ICG). When plasma ICG concentrations were measured 3, 5, 7, 10 and 15 min after time zero, the removal slope for ICG was consistently exponential for the 15-min observation period. The slope was similar between the two ICG administrations in log scale. When disappearance rates of ICG 10 min after time zero between the 0.1 and 0.5 mg/kg tests were compared, a significant correlation (p\u003c0.01) was obtained. Serum bilirubin fluctuation ranging from 0.4 to 3.7 mg/dl had no meaningful effect on the efficacy of the 0.1 mg/kg ICG test. These results suggest that an ICG 0.1mg/kg test is accurate enough to estimate the liver function, and has potential value for clinical application.", "subitem_description_type": "Abstract"}]}, "item_7_publisher_7": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Niigata University School of Medicine"}]}, "item_7_select_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_7_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA00508361", "subitem_source_identifier_type": "NCID"}]}, "item_7_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "05677734", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Aono, Takashi"}], "nameIdentifiers": [{"nameIdentifier": "53172", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tsukada, Kazuhiro"}], "nameIdentifiers": [{"nameIdentifier": "53173", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sakaguchi, Takeo"}], "nameIdentifiers": [{"nameIdentifier": "53174", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ishiduka, Dai"}], "nameIdentifiers": [{"nameIdentifier": "53175", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Suzuki, Tsutomu"}], "nameIdentifiers": [{"nameIdentifier": "53176", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hatakeyama, Katsuyoshi"}], "nameIdentifiers": [{"nameIdentifier": "53177", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-08-06"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "42(4)_165-169.pdf", "filesize": [{"value": "388.8 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 388800.0, "url": {"label": "42(4)_165-169.pdf", "url": "https://niigata-u.repo.nii.ac.jp/record/6489/files/42(4)_165-169.pdf"}, "version_id": "6f07551d-4540-46b2-afb4-94ffabb78de4"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Utilization of Low Dose Indocyanine Green Test for Evaluating Liver Function", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Utilization of Low Dose Indocyanine Green Test for Evaluating Liver Function"}, {"subitem_title": "Utilization of Low Dose Indocyanine Green Test for Evaluating Liver Function", "subitem_title_language": "en"}]}, "item_type_id": "7", "owner": "1", "path": ["456", "625"], "permalink_uri": "http://hdl.handle.net/10191/33256", "pubdate": {"attribute_name": "公開日", "attribute_value": "2015-09-04"}, "publish_date": "2015-09-04", "publish_status": "0", "recid": "6489", "relation": {}, "relation_version_is_last": true, "title": ["Utilization of Low Dose Indocyanine Green Test for Evaluating Liver Function"], "weko_shared_id": null}
Utilization of Low Dose Indocyanine Green Test for Evaluating Liver Function
http://hdl.handle.net/10191/33256
http://hdl.handle.net/10191/33256d8fe3ef9-26a8-468b-aaf9-5da52426033a
名前 / ファイル | ライセンス | アクション |
---|---|---|
42(4)_165-169.pdf (388.8 kB)
|
|
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2015-09-04 | |||||
タイトル | ||||||
タイトル | Utilization of Low Dose Indocyanine Green Test for Evaluating Liver Function | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Utilization of Low Dose Indocyanine Green Test for Evaluating Liver Function | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | departmental bulletin paper | |||||
著者 |
Aono, Takashi
× Aono, Takashi× Tsukada, Kazuhiro× Sakaguchi, Takeo× Ishiduka, Dai× Suzuki, Tsutomu× Hatakeyama, Katsuyoshi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Liver function was examined in 60 patients with a 0.1 and 0.5 mg/kg intravenous bolus of indocyanine green (ICG). When plasma ICG concentrations were measured 3, 5, 7, 10 and 15 min after time zero, the removal slope for ICG was consistently exponential for the 15-min observation period. The slope was similar between the two ICG administrations in log scale. When disappearance rates of ICG 10 min after time zero between the 0.1 and 0.5 mg/kg tests were compared, a significant correlation (p<0.01) was obtained. Serum bilirubin fluctuation ranging from 0.4 to 3.7 mg/dl had no meaningful effect on the efficacy of the 0.1 mg/kg ICG test. These results suggest that an ICG 0.1mg/kg test is accurate enough to estimate the liver function, and has potential value for clinical application. | |||||
書誌情報 |
Acta medica et biologica en : Acta medica et biologica 巻 42, 号 4, p. 165-169, 発行日 1994-12 |
|||||