{"created":"2021-03-01T06:07:48.487222+00:00","id":4025,"links":{},"metadata":{"_buckets":{"deposit":"326058b9-ea8e-4d14-98bf-d26803149be4"},"_deposit":{"id":"4025","owners":[],"pid":{"revision_id":0,"type":"depid","value":"4025"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00004025","sets":["423:424:425","453:454"]},"item_5_alternative_title_1":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"A method to enhance seismic performances of unreinforced masonry structures derived from lateral force resisting mechanisms of masonry infilled frames"}]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006-07","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"166","bibliographicPageStart":"159","bibliographicVolumeNumber":"605","bibliographic_titles":[{"bibliographic_title":"日本建築学会構造系論文集"},{"bibliographic_title":"日本建築学会構造系論文集","bibliographic_titleLang":"en"}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper mainly discusses seismic performances of specially designed unreinforced masonry (URM) structures. Firstly, lateral force resisting mechanisms of masonry in filled frames were introduced through test results of concrete block in filled reinforced concrete frames with and without a door opening. Based on major findings from the tests, a method to enhance seismic performances of URM structures using interlocking masonry units was proposed. Two new URM walls consisting of brittle and ductile interlocking masonry units were tested and their performances were compared with that of a conventional one. Seismic performances of URM walls could be effectively improved by interlocking masonry units.","subitem_description_type":"Abstract"}]},"item_5_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"46911","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Sanada, Yasushi"}]},{"nameIdentifiers":[{"nameIdentifier":"46912","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Nakamura, Yukiko"}]},{"nameIdentifiers":[{"nameIdentifier":"46913","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Yamauchi, Naruhito"}]},{"nameIdentifiers":[{"nameIdentifier":"46914","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Choi, Ho"}]},{"nameIdentifiers":[{"nameIdentifier":"46915","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Nakano, Yoshiaki"}]}]},"item_5_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本建築学会"}]},"item_5_relation_31":{"attribute_name":"異版である","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"http://ci.nii.ac.jp/naid/110004763699","subitem_relation_type_select":"URI"}}]},"item_5_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"社団法人日本建築学会"},{"subitem_rights":"本文データは学協会の許諾に基づきCiNiiから複製したものである"}]},"item_5_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_5_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN10438559","subitem_source_identifier_type":"NCID"}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13404202","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"真田, 靖士"}],"nameIdentifiers":[{"nameIdentifier":"46906","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中村, 友紀子"}],"nameIdentifiers":[{"nameIdentifier":"46907","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山内, 成人"}],"nameIdentifiers":[{"nameIdentifier":"46908","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"雀, Ho"}],"nameIdentifiers":[{"nameIdentifier":"46909","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中埜, 良昭"}],"nameIdentifiers":[{"nameIdentifier":"46910","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-07-30"}],"displaytype":"detail","filename":"110004763699.pdf","filesize":[{"value":"1.2 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"110004763699.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/4025/files/110004763699.pdf"},"version_id":"a5f69246-328e-4348-a0e3-07f78ebce15d"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"れんが","subitem_subject_scheme":"Other"},{"subitem_subject":"繊維補強セメン複合材料","subitem_subject_scheme":"Other"},{"subitem_subject":"インターロッキング機構","subitem_subject_scheme":"Other"},{"subitem_subject":"耐震補強","subitem_subject_scheme":"Other"},{"subitem_subject":"静的載荷実験","subitem_subject_scheme":"Other"},{"subitem_subject":"無補強組積造","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"枠組組積造壁の水平力抵抗機構から推察される無補強組積造建築の高耐震化技術","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"枠組組積造壁の水平力抵抗機構から推察される無補強組積造建築の高耐震化技術"},{"subitem_title":"枠組組積造壁の水平力抵抗機構から推察される無補強組積造建築の高耐震化技術","subitem_title_language":"en"}]},"item_type_id":"5","owner":"1","path":["454","425"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-06-05"},"publish_date":"2012-06-05","publish_status":"0","recid":"4025","relation_version_is_last":true,"title":["枠組組積造壁の水平力抵抗機構から推察される無補強組積造建築の高耐震化技術"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-15T03:37:01.417530+00:00"}