@article{oai:niigata-u.repo.nii.ac.jp:00004024, author = {加藤, 大介 and 李, 柱振 and 中村, 友紀子 and 本多, 良政}, journal = {日本建築学会構造系論文集, 日本建築学会構造系論文集}, month = {Dec}, note = {Objectives of this study were to examine axial load carrying capacities of R/C columns after shear failure. For this purpose static loading tests of R/C columns were conducted. Confinement of hoop reinforcement to core concrete was one of the most important effects to be discussed so different hoop reinforcement details were studied, i.e. welded hoop for good confinement type, hoop with 135 deg hook for normal confinement type and hoop with 90 deg hook for poor confinement. Using these specimens centrical axial loading test to examine the basic confining effects and lateral loading test under constant axial load to examine the axial load carrying capacity were conducted.}, pages = {153--159}, title = {配筋詳細に着目したRC造せん断破壊柱の軸力保持性能に関する実験 : 軸加力実験と曲げせん断加力実験の関係}, volume = {610}, year = {2006} }