{"created":"2021-03-01T06:07:46.166096+00:00","id":3988,"links":{},"metadata":{"_buckets":{"deposit":"a29f6ce0-1a53-42c9-8655-37f7cc35afef"},"_deposit":{"id":"3988","owners":[],"pid":{"revision_id":0,"type":"depid","value":"3988"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00003988","sets":["423:424:425","453:454"]},"item_5_alternative_title_1":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"DEVELOPMENT OF FLUCTYATING AIRFLOW GENERATOR FOR THE INDOOR AIRFLOW CAUSED BY CROSS VENTILATION"}]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2009-10","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"31","bibliographicPageEnd":"816","bibliographicPageStart":"813","bibliographicVolumeNumber":"15","bibliographic_titles":[{"bibliographic_title":"日本建築学会技術報告集"},{"bibliographic_title":"日本建築学会技術報告集","bibliographic_titleLang":"en"}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Cross ventilation has the effect on improving the comfort of indoor environment. However, this effect has not been clarified since it is difficult to artificially reproduce the same indoor air-flow as cross ventilation. We have developed a device that is able to generate the fluctuating air-flow of same properties as an air-flow of the cross ventilated room. The verification results of the device's performance are as follows: (1)The device that combines a slider and a damper can generate the fluctuating ir-flow similar to natural cross ventilation. (2)The properties of the reproduced air-flow virtually correspond to those of natural cross ventilation.","subitem_description_type":"Abstract"}]},"item_5_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"46604","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Sato, Hideki"}]},{"nameIdentifiers":[{"nameIdentifier":"46605","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Akabayashi, Shin-ichi"}]},{"nameIdentifiers":[{"nameIdentifier":"46606","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Sakaguchi, Jun"}]},{"nameIdentifiers":[{"nameIdentifier":"46607","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Kuwahara, Ryoichi"}]}]},"item_5_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本建築学会"}]},"item_5_relation_31":{"attribute_name":"異版である","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.jstage.jst.go.jp/article/aijt/15/31/15_31_813/_pdf","subitem_relation_type_select":"URI"}}]},"item_5_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"社団法人日本建築学会"},{"subitem_rights":"本文データは学協会の許諾に基づきJ-STAGEから複製したものである"}]},"item_5_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_5_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN10531441","subitem_source_identifier_type":"NCID"}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13419463","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"佐藤, 英樹"}],"nameIdentifiers":[{"nameIdentifier":"46600","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"赤林, 伸一"}],"nameIdentifiers":[{"nameIdentifier":"46601","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"坂口, 淳"}],"nameIdentifiers":[{"nameIdentifier":"46602","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"桑原, 亮一"}],"nameIdentifiers":[{"nameIdentifier":"46603","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-07-30"}],"displaytype":"detail","filename":"15_31_813-816.pdf","filesize":[{"value":"518.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"15_31_813-816.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/3988/files/15_31_813-816.pdf"},"version_id":"9fffdaed-ec7e-413d-b75f-ec56d50d0a0d"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"通風","subitem_subject_scheme":"Other"},{"subitem_subject":"自然風","subitem_subject_scheme":"Other"},{"subitem_subject":"変動気流","subitem_subject_scheme":"Other"},{"subitem_subject":"周波数スペクトル","subitem_subject_scheme":"Other"},{"subitem_subject":"Cross ventilation","subitem_subject_scheme":"Other"},{"subitem_subject":"Natural wind","subitem_subject_scheme":"Other"},{"subitem_subject":"Fluctuating airflow","subitem_subject_scheme":"Other"},{"subitem_subject":"Frequency spectrum","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"通風時の室内気流を対象とした変動気流発生装置の開発","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"通風時の室内気流を対象とした変動気流発生装置の開発"},{"subitem_title":"通風時の室内気流を対象とした変動気流発生装置の開発","subitem_title_language":"en"}]},"item_type_id":"5","owner":"1","path":["454","425"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-10-05"},"publish_date":"2012-10-05","publish_status":"0","recid":"3988","relation_version_is_last":true,"title":["通風時の室内気流を対象とした変動気流発生装置の開発"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-15T03:36:59.021304+00:00"}