{"created":"2021-03-01T06:07:44.749611+00:00","id":3965,"links":{},"metadata":{"_buckets":{"deposit":"bdf18d4c-0b71-438c-869b-679a3c78817d"},"_deposit":{"id":"3965","owners":[],"pid":{"revision_id":0,"type":"depid","value":"3965"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00003965","sets":["453:454","468:469:470"]},"item_5_alternative_title_1":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"STUDY ON THE HEAT LOSS OF THE DETACHED HOUSE WHEN HEATED BY BOTH FLOOR HEATING AND AIR-CONDITIONING"}]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-06","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"628","bibliographicPageEnd":"742","bibliographicPageStart":"735","bibliographicVolumeNumber":"73","bibliographic_titles":[{"bibliographic_title":"日本建築学会環境系論文集"},{"bibliographic_title":"日本建築学会環境系論文集","bibliographic_titleLang":"en"}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This study carries out a field measurement survey and CFD calculation about the heat loss of a house when heated by the floor heating and the air conditioning were analyzed in detail. The energy consumption in the actual condition of both the floor heating and the air conditioning is clarified. The results of the measurement are as follows: (1) In this investigation, the heat load of the floor heating is 421[MJ/day}, the heat load of the air-conditioning is 405[MJ/day]. (2) CFD calculation results that SET* is about 22[℃], heat loss of a floor heating is more than air-conditioning. (3) Wall surface temperature of the floor heating becomes relatively high, the heat losses from a wall become large. (4) Room air temperature of floor heating is lower than air-conditioning, the heat load of ventilation is smaller than floor heating.","subitem_description_type":"Abstract"}]},"item_5_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"46372","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Sakaguchi, Jun"}]},{"nameIdentifiers":[{"nameIdentifier":"46373","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Akabayashi, Shin-ichi"}]},{"nameIdentifiers":[{"nameIdentifier":"46374","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Hasegawa, Hiroshi"}]},{"nameIdentifiers":[{"nameIdentifier":"46375","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Asama, Hideki"}]}]},"item_5_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本建築学会"}]},"item_5_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"社団法人日本建築学会"}]},"item_5_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_5_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11830377","subitem_source_identifier_type":"NCID"}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13480685","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"坂口, 淳"}],"nameIdentifiers":[{"nameIdentifier":"46368","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"赤林, 伸一"}],"nameIdentifiers":[{"nameIdentifier":"46369","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"長谷川, 弘"}],"nameIdentifiers":[{"nameIdentifier":"46370","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"浅間, 英樹"}],"nameIdentifiers":[{"nameIdentifier":"46371","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-07-30"}],"displaytype":"detail","filename":"ZF_628_735-742.pdf","filesize":[{"value":"1.2 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"ZF_628_735-742.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/3965/files/ZF_628_735-742.pdf"},"version_id":"31a2a8ac-1537-4c3b-b6e6-fd9b3318c3dd"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Floor heating","subitem_subject_scheme":"Other"},{"subitem_subject":"Radiation","subitem_subject_scheme":"Other"},{"subitem_subject":"Energy consumption","subitem_subject_scheme":"Other"},{"subitem_subject":"Computational Fluid Dynamics","subitem_subject_scheme":"Other"},{"subitem_subject":"床暖房","subitem_subject_scheme":"Other"},{"subitem_subject":"放射","subitem_subject_scheme":"Other"},{"subitem_subject":"エネルギー消費量","subitem_subject_scheme":"Other"},{"subitem_subject":"数値流体解析","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"住宅を対象とした床暖房時と温風暖房時の熱収支に関する研究","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"住宅を対象とした床暖房時と温風暖房時の熱収支に関する研究"},{"subitem_title":"住宅を対象とした床暖房時と温風暖房時の熱収支に関する研究","subitem_title_language":"en"}]},"item_type_id":"5","owner":"1","path":["454","470"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-06-05"},"publish_date":"2012-06-05","publish_status":"0","recid":"3965","relation_version_is_last":true,"title":["住宅を対象とした床暖房時と温風暖房時の熱収支に関する研究"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-15T03:36:57.530510+00:00"}