{"created":"2021-03-01T06:07:44.685716+00:00","id":3964,"links":{},"metadata":{"_buckets":{"deposit":"b5f324b8-0507-4cd8-a171-0e9749d6b25d"},"_deposit":{"id":"3964","owners":[],"pid":{"revision_id":0,"type":"depid","value":"3964"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00003964","sets":["453:454","468:469:470"]},"item_5_alternative_title_1":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"STUDY ON THE EVALUATION OF CROSS VENTILATION PERFORMANCE CONSIDERING DISTRIBUTION OF INDOOR AIRFLOW VELOCITY : Evaluation of cross ventilation performance of the detached house with cross ventilation degree hours of inside area"}]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-11","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"633","bibliographicPageEnd":"1266","bibliographicPageStart":"1261","bibliographicVolumeNumber":"73","bibliographic_titles":[{"bibliographic_title":"日本建築学会環境系論文集"},{"bibliographic_title":"日本建築学会環境系論文集","bibliographic_titleLang":"en"}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The distribution of indoor airflow velocity by cross ventilation is influenced by the regional climate conditions, and the location as well as the shape of the building. In this study, CVDHI_B, CVDHI_P and CVDHI_T of Cross Ventilation Degree Hours of Inside Area (CVDHI) are proposed. The CVDHI values of 2 cases to change the number and position of openings at 2 cities (Tokyo and Niigata) in Japan are calculated for the AIJ detached house model.The results are as follows; (1) The ratio of averaged CVDHI_P and CVDHI_B values is about 1:20 in Tokyo and Niigata. (2) The CVDHI values increases when an opening is placed on an opposite wall in a straight line, and placed at the corner of the room.","subitem_description_type":"Abstract"}]},"item_5_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"46363","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Akabayashi, Shin-ichi"}]},{"nameIdentifiers":[{"nameIdentifier":"46364","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Sakaguchi, Jun"}]},{"nameIdentifiers":[{"nameIdentifier":"46365","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Hosono, Atsumi"}]},{"nameIdentifiers":[{"nameIdentifier":"46366","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Sato, Hideki"}]},{"nameIdentifiers":[{"nameIdentifier":"46367","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Kubo, Shunsuke"}]}]},"item_5_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本建築学会"}]},"item_5_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"社団法人日本建築学会"}]},"item_5_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_5_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11830377","subitem_source_identifier_type":"NCID"}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13480685","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"赤林, 伸一"}],"nameIdentifiers":[{"nameIdentifier":"46358","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"坂口, 淳"}],"nameIdentifiers":[{"nameIdentifier":"46359","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"細野, 淳美"}],"nameIdentifiers":[{"nameIdentifier":"46360","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"佐藤, 英樹"}],"nameIdentifiers":[{"nameIdentifier":"46361","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"久保, 俊輔"}],"nameIdentifiers":[{"nameIdentifier":"46362","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-07-30"}],"displaytype":"detail","filename":"ZF_633_1261-1266.pdf","filesize":[{"value":"1.5 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"ZF_633_1261-1266.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/3964/files/ZF_633_1261-1266.pdf"},"version_id":"e71ed2ee-0f84-4302-a1de-1d5a2d541e54"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Cross ventilation","subitem_subject_scheme":"Other"},{"subitem_subject":"Cross ventilation performance","subitem_subject_scheme":"Other"},{"subitem_subject":"SET*","subitem_subject_scheme":"Other"},{"subitem_subject":"Cross Ventilation Degree of Inside Area","subitem_subject_scheme":"Other"},{"subitem_subject":"通風","subitem_subject_scheme":"Other"},{"subitem_subject":"通風性能","subitem_subject_scheme":"Other"},{"subitem_subject":"室内通風デグリアワー","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"室内気流分布を考慮した通風性能評価に関する研究 : 室内通風デグリアワーを用いた戸建住宅の通風性能評価","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"室内気流分布を考慮した通風性能評価に関する研究 : 室内通風デグリアワーを用いた戸建住宅の通風性能評価"},{"subitem_title":"室内気流分布を考慮した通風性能評価に関する研究 : 室内通風デグリアワーを用いた戸建住宅の通風性能評価","subitem_title_language":"en"}]},"item_type_id":"5","owner":"1","path":["454","470"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-06-05"},"publish_date":"2012-06-05","publish_status":"0","recid":"3964","relation_version_is_last":true,"title":["室内気流分布を考慮した通風性能評価に関する研究 : 室内通風デグリアワーを用いた戸建住宅の通風性能評価"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-15T03:36:57.559162+00:00"}