@article{oai:niigata-u.repo.nii.ac.jp:00003964, author = {赤林, 伸一 and 坂口, 淳 and 細野, 淳美 and 佐藤, 英樹 and 久保, 俊輔}, issue = {633}, journal = {日本建築学会環境系論文集, 日本建築学会環境系論文集}, month = {Nov}, note = {The distribution of indoor airflow velocity by cross ventilation is influenced by the regional climate conditions, and the location as well as the shape of the building. In this study, CVDHI_B, CVDHI_P and CVDHI_T of Cross Ventilation Degree Hours of Inside Area (CVDHI) are proposed. The CVDHI values of 2 cases to change the number and position of openings at 2 cities (Tokyo and Niigata) in Japan are calculated for the AIJ detached house model.The results are as follows; (1) The ratio of averaged CVDHI_P and CVDHI_B values is about 1:20 in Tokyo and Niigata. (2) The CVDHI values increases when an opening is placed on an opposite wall in a straight line, and placed at the corner of the room.}, pages = {1261--1266}, title = {室内気流分布を考慮した通風性能評価に関する研究 : 室内通風デグリアワーを用いた戸建住宅の通風性能評価}, volume = {73}, year = {2008} }