{"created":"2021-03-01T06:07:44.624303+00:00","id":3963,"links":{},"metadata":{"_buckets":{"deposit":"1b452fc2-e151-4eaa-ba30-a853ad5a95d8"},"_deposit":{"id":"3963","owners":[],"pid":{"revision_id":0,"type":"depid","value":"3963"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00003963","sets":["453:454","468:469:470"]},"item_5_alternative_title_1":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"CFD ANALYSIS FOR DETACHED HOUSE : Study on the ventilation efficiency on constantly ventilated house Part 1"}]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2009-02","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"636","bibliographicPageEnd":"168","bibliographicPageStart":"161","bibliographicVolumeNumber":"74","bibliographic_titles":[{"bibliographic_title":"日本建築学会環境系論文集"},{"bibliographic_title":"日本建築学会環境系論文集","bibliographic_titleLang":"en"}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper describes the distribution of local air exchange efficiency (ε_p) in the living room when the layout of supply outlets and exhaust inlets and the position of air-conditioners is changed.The results are as follows; (1) The value of mean ε_p of breathing zone becomes about 1.0 because fresh air spread completely in the room when air-conditioners are operated. (2) In the case when air-conditioners are not operated, the mean ε_p becomes smaller than 1.0, and the poor area of ventilation efficiency becomes large. (3) Ventilation efficiency is influenced by the layout of the supply outlets and exhaust inlets.","subitem_description_type":"Abstract"}]},"item_5_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"46355","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Kaji, Hiroko"}]},{"nameIdentifiers":[{"nameIdentifier":"46356","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Akabayashi, Shin-ichi"}]},{"nameIdentifiers":[{"nameIdentifier":"46357","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Sakaguchi, Jun"}]}]},"item_5_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本建築学会"}]},"item_5_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"社団法人日本建築学会"}]},"item_5_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_5_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11830377","subitem_source_identifier_type":"NCID"}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13480685","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"鍛冶, 紘子"}],"nameIdentifiers":[{"nameIdentifier":"46352","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"赤林, 伸一"}],"nameIdentifiers":[{"nameIdentifier":"46353","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"坂口, 淳"}],"nameIdentifiers":[{"nameIdentifier":"46354","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-07-30"}],"displaytype":"detail","filename":"ZF_636_161-168.pdf","filesize":[{"value":"2.8 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"ZF_636_161-168.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/3963/files/ZF_636_161-168.pdf"},"version_id":"de985640-a78f-407b-a5ac-8d65c108d08f"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Local air exchange efficiencey","subitem_subject_scheme":"Other"},{"subitem_subject":"Indoor thermal environment","subitem_subject_scheme":"Other"},{"subitem_subject":"Age of air","subitem_subject_scheme":"Other"},{"subitem_subject":"Breathing zone","subitem_subject_scheme":"Other"},{"subitem_subject":"局所空気交換効率","subitem_subject_scheme":"Other"},{"subitem_subject":"室内温熱環境","subitem_subject_scheme":"Other"},{"subitem_subject":"空気齢","subitem_subject_scheme":"Other"},{"subitem_subject":"室内呼吸域","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"戸建住宅を対象としたCFD解析 : 常時換気システムが設置された住宅の換気効率に関する研究 その1","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"戸建住宅を対象としたCFD解析 : 常時換気システムが設置された住宅の換気効率に関する研究 その1"},{"subitem_title":"戸建住宅を対象としたCFD解析 : 常時換気システムが設置された住宅の換気効率に関する研究 その1","subitem_title_language":"en"}]},"item_type_id":"5","owner":"1","path":["454","470"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-06-05"},"publish_date":"2012-06-05","publish_status":"0","recid":"3963","relation_version_is_last":true,"title":["戸建住宅を対象としたCFD解析 : 常時換気システムが設置された住宅の換気効率に関する研究 その1"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-15T03:36:57.587310+00:00"}