@article{oai:niigata-u.repo.nii.ac.jp:00003963, author = {鍛冶, 紘子 and 赤林, 伸一 and 坂口, 淳}, issue = {636}, journal = {日本建築学会環境系論文集, 日本建築学会環境系論文集}, month = {Feb}, note = {This paper describes the distribution of local air exchange efficiency (ε_p) in the living room when the layout of supply outlets and exhaust inlets and the position of air-conditioners is changed.The results are as follows; (1) The value of mean ε_p of breathing zone becomes about 1.0 because fresh air spread completely in the room when air-conditioners are operated. (2) In the case when air-conditioners are not operated, the mean ε_p becomes smaller than 1.0, and the poor area of ventilation efficiency becomes large. (3) Ventilation efficiency is influenced by the layout of the supply outlets and exhaust inlets.}, pages = {161--168}, title = {戸建住宅を対象としたCFD解析 : 常時換気システムが設置された住宅の換気効率に関する研究 その1}, volume = {74}, year = {2009} }