{"created":"2021-03-01T06:07:42.397939+00:00","id":3927,"links":{},"metadata":{"_buckets":{"deposit":"67eb0f17-80d8-4ba6-95c6-65c8e59e9b7f"},"_deposit":{"id":"3927","owners":[],"pid":{"revision_id":0,"type":"depid","value":"3927"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00003927","sets":["423:424:425","453:454"]},"item_5_alternative_title_1":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"A Method of Improving the Accuracy of the Three-Coordinate Measuring Machine : 1st Report, A Trial Production of the Three-Dimensional Standard"}]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1987-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"485","bibliographicPageEnd":"120","bibliographicPageStart":"117","bibliographicVolumeNumber":"53","bibliographic_titles":[{"bibliographic_title":"日本機械学会論文集. C編"},{"bibliographic_title":"日本機械学会論文集. C編","bibliographic_titleLang":"en"}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The trial production and the inspection test of a three-dimensional standard gauge equipment are carried out. Two types of equipment are designed for the calibration test of the three-coordinate measuring machine(3CMM). Each equipment is fabricated from precision steel balls arranged on a base plate- (1) 20 pieces of ball are placed in a rectangular lattice shape on nearly the same plane - (2) 3 of 9 pieces are spaced on three different heights. The measuring probe is positioned on the balls and the center coordinates are measured to determine the three-dimensional relation of each ball position. The inspection test of the standard gauges are performed with the 3CMM whose discrete distribution of the error vector is already known. The repeatability and the reproducibility are observed in the test. As a result, the standard gauge equipment built as a trial proved to be adequate for practical use in the calibration test of other 3CMM.","subitem_description_type":"Abstract"}]},"item_5_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"46203","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Oya, Makoto"}]},{"nameIdentifiers":[{"nameIdentifier":"46204","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Hokari, Hisashi"}]},{"nameIdentifiers":[{"nameIdentifier":"46205","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Tamura, Hisashi"}]}]},"item_5_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本機械学会"}]},"item_5_relation_31":{"attribute_name":"異版である","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"http://ci.nii.ac.jp/naid/110002389893","subitem_relation_type_select":"URI"}}]},"item_5_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"日本機械学会"},{"subitem_rights":"本文データは学会の許諾に基づくCiNiiからの複製である"}]},"item_5_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_5_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00187463","subitem_source_identifier_type":"NCID"}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"03875024","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"大矢, 誠"}],"nameIdentifiers":[{"nameIdentifier":"46200","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"穂苅, 久"}],"nameIdentifiers":[{"nameIdentifier":"46201","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田村, 久司"}],"nameIdentifiers":[{"nameIdentifier":"46202","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-07-30"}],"displaytype":"detail","filename":"9_0187.pdf","filesize":[{"value":"491.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"9_0187.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/3927/files/9_0187.pdf"},"version_id":"28b78fed-a47b-4d62-a545-56043c47f9e7"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Measurement","subitem_subject_scheme":"Other"},{"subitem_subject":"Accuracy","subitem_subject_scheme":"Other"},{"subitem_subject":"Three-Coordinate Measuring Machine","subitem_subject_scheme":"Other"},{"subitem_subject":"Three-Dimensional Standard","subitem_subject_scheme":"Other"},{"subitem_subject":"Inspection","subitem_subject_scheme":"Other"},{"subitem_subject":"Error Vector","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"三次元座標測定機の精度向上法(第1報, 三次元用ゲージの試作)","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"三次元座標測定機の精度向上法(第1報, 三次元用ゲージの試作)"},{"subitem_title":"三次元座標測定機の精度向上法(第1報, 三次元用ゲージの試作)","subitem_title_language":"en"}]},"item_type_id":"5","owner":"1","path":["454","425"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-04-08"},"publish_date":"2008-04-08","publish_status":"0","recid":"3927","relation_version_is_last":true,"title":["三次元座標測定機の精度向上法(第1報, 三次元用ゲージの試作)"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-15T03:36:56.962312+00:00"}