{"_buckets": {"deposit": "3bb00f22-133f-4a7d-9f95-2449b6484ed6"}, "_deposit": {"id": "3917", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "3917"}, "status": "published"}, "_oai": {"id": "oai:niigata-u.repo.nii.ac.jp:00003917", "sets": ["454", "425"]}, "item_5_alternative_title_1": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "A Method of Improving the Accurasy of the Three-coordinate Measuring Machine : 2nd Report, Calibration Method Using the Three-dimensional Standard"}]}, "item_5_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1988-07", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "503", "bibliographicPageEnd": "1451", "bibliographicPageStart": "1445", "bibliographicVolumeNumber": "54", "bibliographic_titles": [{"bibliographic_title": "日本機械学会論文集. C編"}, {"bibliographic_title": "日本機械学会論文集. C編", "bibliographic_titleLang": "en"}]}]}, "item_5_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A calibration method of the three-coordinate measuring machine (3CMM) is presented. Two types of three-dimensional standard gage made by the authors were used for the calibration test. In this method, the error vector was directly observed and determined by comparing the measured value with the true value of the gage. The discrete distribution of the error vector was thus obtained. This method is convenient for machine shop applications. Based on the proposed method, the calibration test was performed on the 3CMM. To verify the accuracy of the calibrated 3CMM, distance measurements were performed using the gage blocks, and the measured values were corrected. As a results, it was clarified that the error correction using the result of the calibration test improves the accuracy of the 3CMM.", "subitem_description_type": "Abstract"}]}, "item_5_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "46145", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Oya, Makoto"}]}, {"nameIdentifiers": [{"nameIdentifier": "46146", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Hokari, Hisashi"}]}, {"nameIdentifiers": [{"nameIdentifier": "46147", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Tamura, Hisashi"}]}]}, "item_5_publisher_7": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本機械学会"}]}, "item_5_relation_31": {"attribute_name": "異版である", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://ci.nii.ac.jp/naid/110002390869", "subitem_relation_type_select": "URI"}}]}, "item_5_rights_15": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "日本機械学会"}, {"subitem_rights": "本文データは学会の許諾に基づくCiNiiからの複製である"}]}, "item_5_select_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_5_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00187463", "subitem_source_identifier_type": "NCID"}]}, "item_5_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "03875024", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "大矢, 誠"}], "nameIdentifiers": [{"nameIdentifier": "46142", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "穂苅, 久"}], "nameIdentifiers": [{"nameIdentifier": "46143", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "田村, 久司"}], "nameIdentifiers": [{"nameIdentifier": "46144", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-07-30"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "9_0191.pdf", "filesize": [{"value": "619.4 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 619400.0, "url": {"label": "9_0191.pdf", "url": "https://niigata-u.repo.nii.ac.jp/record/3917/files/9_0191.pdf"}, "version_id": "90179aa3-ebc5-4937-bbed-981e7d191557"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Measurement", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Accuracy", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Three-coordinate Measuring Machine", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Three-dimensional Standard", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Calibration", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Error Vector", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "三次元座標測定機の精度向上法(第2報, 三次元用ゲージによる校正)", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "三次元座標測定機の精度向上法(第2報, 三次元用ゲージによる校正)"}, {"subitem_title": "三次元座標測定機の精度向上法(第2報, 三次元用ゲージによる校正)", "subitem_title_language": "en"}]}, "item_type_id": "5", "owner": "1", "path": ["454", "425"], "permalink_uri": "http://hdl.handle.net/10191/5893", "pubdate": {"attribute_name": "公開日", "attribute_value": "2008-04-08"}, "publish_date": "2008-04-08", "publish_status": "0", "recid": "3917", "relation": {}, "relation_version_is_last": true, "title": ["三次元座標測定機の精度向上法(第2報, 三次元用ゲージによる校正)"], "weko_shared_id": null}
三次元座標測定機の精度向上法(第2報, 三次元用ゲージによる校正)
http://hdl.handle.net/10191/5893
http://hdl.handle.net/10191/589354185241-080a-4284-a749-0a864abe290e
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2008-04-08 | |||||
タイトル | ||||||
タイトル | 三次元座標測定機の精度向上法(第2報, 三次元用ゲージによる校正) | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | 三次元座標測定機の精度向上法(第2報, 三次元用ゲージによる校正) | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Measurement | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Accuracy | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Three-coordinate Measuring Machine | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Three-dimensional Standard | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Calibration | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Error Vector | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
その他のタイトル | ||||||
その他のタイトル | A Method of Improving the Accurasy of the Three-coordinate Measuring Machine : 2nd Report, Calibration Method Using the Three-dimensional Standard | |||||
著者 |
大矢, 誠
× 大矢, 誠× 穂苅, 久× 田村, 久司 |
|||||
著者別名 | ||||||
識別子 | 46145 | |||||
識別子Scheme | WEKO | |||||
姓名 | Oya, Makoto | |||||
著者別名 | ||||||
識別子 | 46146 | |||||
識別子Scheme | WEKO | |||||
姓名 | Hokari, Hisashi | |||||
著者別名 | ||||||
識別子 | 46147 | |||||
識別子Scheme | WEKO | |||||
姓名 | Tamura, Hisashi | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A calibration method of the three-coordinate measuring machine (3CMM) is presented. Two types of three-dimensional standard gage made by the authors were used for the calibration test. In this method, the error vector was directly observed and determined by comparing the measured value with the true value of the gage. The discrete distribution of the error vector was thus obtained. This method is convenient for machine shop applications. Based on the proposed method, the calibration test was performed on the 3CMM. To verify the accuracy of the calibrated 3CMM, distance measurements were performed using the gage blocks, and the measured values were corrected. As a results, it was clarified that the error correction using the result of the calibration test improves the accuracy of the 3CMM. | |||||
書誌情報 |
日本機械学会論文集. C編 en : 日本機械学会論文集. C編 巻 54, 号 503, p. 1445-1451, 発行日 1988-07 |
|||||
出版者 | ||||||
出版者 | 日本機械学会 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 03875024 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00187463 | |||||
権利 | ||||||
権利情報 | 日本機械学会 | |||||
権利 | ||||||
権利情報 | 本文データは学会の許諾に基づくCiNiiからの複製である | |||||
著者版フラグ | ||||||
値 | publisher | |||||
異版である | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | URI | |||||
関連識別子 | http://ci.nii.ac.jp/naid/110002390869 |