@article{oai:niigata-u.repo.nii.ac.jp:00003754, author = {前川, 博 and 小林, 睦夫 and 矢代, 一男}, issue = {492}, journal = {日本機械学会論文集. B編, 日本機械学会論文集. B編}, month = {Aug}, note = {A temperature-sensitive hot-wire under constant-temperature operation is analyzed to predict its frequency response to temperature fluctuations of the fluid. Effects of the finite Wollaston length, the over-heat ratio and the transconductance of the amplifier are taken into account, and a precise expression for the transfer function is derived. Various probes with different geometries are dynamically calibrated using the new developed procedure, in which a linear temperature distribution or a thermal wake just behind parallel line-sources is utilized to generate prescribed temperature fluctuations over a wider range of frequencies. Good agreement is obtained between the predictions and the experimental results on the gain of the sensitivity. The gain increases slightly as the over-heat ratio increases, and is least affected by the transconductance. Owing to the moderate thermal inertia of the Wollaston portion, the attenuation in the gain sometimes appears in the range of energy-containing eddies.}, pages = {2560--2566}, title = {定温熱線の温度変動に対する周波数応答}, volume = {53}, year = {1987} }