{"created":"2021-03-01T06:07:29.244580+00:00","id":3720,"links":{},"metadata":{"_buckets":{"deposit":"246662e8-31b3-4617-bd96-f647a1380b7a"},"_deposit":{"id":"3720","owners":[],"pid":{"revision_id":0,"type":"depid","value":"3720"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00003720","sets":["423:424:425","453:454"]},"item_5_alternative_title_1":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Numerical Simulation of Buoyancy Assisting Backward-Facing Step Flow and Heat Transfer in a Rectangular Duct"}]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1997-08","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"612","bibliographicPageEnd":"2824","bibliographicPageStart":"2817","bibliographicVolumeNumber":"63","bibliographic_titles":[{"bibliographic_title":"日本機械学会論文集. B編"},{"bibliographic_title":"日本機械学会論文集. B編","bibliographic_titleLang":"en"}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Two-and three-dimensional numerical simulations have been performed for mixed convective upward flows over a backward-facing step in a duct. The Reynolds number, expansion ratio and aspect ratio (in 3D sim.) were kept constant at Re=125,ER=2 and AR=16,respectively. The heat flux at the wall downstream of the step was uniform, while the straight wall, the step and the side walls (in 3D sim.) were assumed to be adiabatic. The effect of the buoyancy level, Ri^*, was the major interest in this study. It was found that the reattachment point and the peak Nusselt number point moved upstream as Ri^* was increased, while the secondary recirculation region, which developed at the corner of the step, became larger. It was also found that there existed a secondary flow in a cross section immediately downstream of the step. Flow directed toward the center of the duct becomes more intensive as Ri^* increases, which possibly results in an increase in the level of three-dimensionality of the flow and thermal fields.","subitem_description_type":"Abstract"}]},"item_5_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"44928","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Iwai, Hiroshi"}]},{"nameIdentifiers":[{"nameIdentifier":"44929","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Matsubara, Koji"}]},{"nameIdentifiers":[{"nameIdentifier":"44930","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Nakabe, Kazuyoshi"}]},{"nameIdentifiers":[{"nameIdentifier":"44931","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Suzuki, Kenjiro"}]}]},"item_5_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本機械学会"}]},"item_5_relation_31":{"attribute_name":"異版である","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"http://ci.nii.ac.jp/naid/110002396573","subitem_relation_type_select":"URI"}}]},"item_5_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"日本機械学会"},{"subitem_rights":"本文データは学会の許諾に基づくCiNiiからの複製である"}]},"item_5_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_5_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00187441","subitem_source_identifier_type":"NCID"}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"03875016","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"岩井, 裕"}],"nameIdentifiers":[{"nameIdentifier":"44924","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"松原, 幸治"}],"nameIdentifiers":[{"nameIdentifier":"44925","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中部, 主敬"}],"nameIdentifiers":[{"nameIdentifier":"44926","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鈴木, 健二郎"}],"nameIdentifiers":[{"nameIdentifier":"44927","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-07-30"}],"displaytype":"detail","filename":"9_0050.pdf","filesize":[{"value":"1.1 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"9_0050.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/3720/files/9_0050.pdf"},"version_id":"09cd5036-5690-4211-9a17-68740ec4ec2b"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Numerical Analysis","subitem_subject_scheme":"Other"},{"subitem_subject":"Heat Transfer","subitem_subject_scheme":"Other"},{"subitem_subject":"Internal Flow","subitem_subject_scheme":"Other"},{"subitem_subject":"Backward Facing Step","subitem_subject_scheme":"Other"},{"subitem_subject":"Separation and Reattachment","subitem_subject_scheme":"Other"},{"subitem_subject":"Buoyancy Assisting Flow","subitem_subject_scheme":"Other"},{"subitem_subject":"Low Reynolds Number","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"後ろ向きステップ鉛直上昇共存対流の熱流動数値解析","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"後ろ向きステップ鉛直上昇共存対流の熱流動数値解析"},{"subitem_title":"後ろ向きステップ鉛直上昇共存対流の熱流動数値解析","subitem_title_language":"en"}]},"item_type_id":"5","owner":"1","path":["454","425"],"pubdate":{"attribute_name":"公開日","attribute_value":"2008-04-08"},"publish_date":"2008-04-08","publish_status":"0","recid":"3720","relation_version_is_last":true,"title":["後ろ向きステップ鉛直上昇共存対流の熱流動数値解析"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-15T03:36:49.160571+00:00"}