ログイン
言語:

WEKO3

  • トップ
  • コミュニティ
  • ランキング
AND
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "0d1aa0ec-48ca-4df0-8eae-e7943af8fce4"}, "_deposit": {"id": "3683", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "3683"}, "status": "published"}, "_oai": {"id": "oai:niigata-u.repo.nii.ac.jp:00003683"}, "item_5_alternative_title_1": {"attribute_name": "\u305d\u306e\u4ed6\u306e\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_alternative_title": "X-Ray Elastic Constants and Residual Stress Distributions of Zirconia Thermal Barrier Coating"}]}, "item_5_biblio_info_6": {"attribute_name": "\u66f8\u8a8c\u60c5\u5831", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2001-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "655", "bibliographicPageEnd": "423", "bibliographicPageStart": "417", "bibliographicVolumeNumber": "67", "bibliographic_titles": [{"bibliographic_title": "\u65e5\u672c\u6a5f\u68b0\u5b66\u4f1a\u8ad6\u6587\u96c6. A\u7de8"}, {"bibliographic_title": "\u65e5\u672c\u6a5f\u68b0\u5b66\u4f1a\u8ad6\u6587\u96c6. A\u7de8", "bibliographic_titleLang": "en"}]}]}, "item_5_description_4": {"attribute_name": "\u6284\u9332", "attribute_value_mlt": [{"subitem_description": "Accurate values of X-ray elastic constants are required for a reliable stress measurement of thermal barrier coating films (TBC films). In this paper, atmosphere and pressureless plasma sprayed TBC films were removed from substrates, then X-ray elastic constants of both TBC films were determained by using newly developed tensile jig. For the atmosphere plasma sprayed film, the value of the mechanical elastic constant was much smaller than the X-ray elastic constant owing to cracks or pores existing in the films. The X-ray elastic constant of the atmosphere plasma sprayed TBC film was nearly equal to that of the pressureless plasma sprayed film. This means that the X-ray elastic constants are little influenced by cracks or pores. Residual stress distributions in both films coated on the substrates were obtained. In the surface region with the depth up 60 \u03bcm, residual stresses of both films showed a drastic variation. This variation of the residual stresses was build up during rapid quenching and solidifying of the molten droplet. In deeper regions, residual stresses were nearly constant. These constant values of residual stresses are caused by the thermal strain mismatch between the TBC film and the substrate.", "subitem_description_type": "Abstract"}]}, "item_5_full_name_3": {"attribute_name": "\u8457\u8005\u5225\u540d", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "44648", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Suzuki, Kenji"}]}, {"nameIdentifiers": [{"nameIdentifier": "44649", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Machiya, Syutaro"}]}, {"nameIdentifiers": [{"nameIdentifier": "44650", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Tanaka, Keisuke"}]}, {"nameIdentifiers": [{"nameIdentifier": "44651", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Sakaida, Yoshihisa"}]}]}, "item_5_publisher_7": {"attribute_name": "\u51fa\u7248\u8005", "attribute_value_mlt": [{"subitem_publisher": "\u65e5\u672c\u6a5f\u68b0\u5b66\u4f1a"}]}, "item_5_relation_31": {"attribute_name": "\u7570\u7248\u3067\u3042\u308b", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://ci.nii.ac.jp/naid/110002369802", "subitem_relation_type_select": "URI"}}]}, "item_5_rights_15": {"attribute_name": "\u6a29\u5229", "attribute_value_mlt": [{"subitem_rights": "\u65e5\u672c\u6a5f\u68b0\u5b66\u4f1a / \u672c\u6587\u30c7\u30fc\u30bf\u306f\u5b66\u4f1a\u306e\u8a31\u8afe\u306b\u57fa\u3065\u304fCiNii\u304b\u3089\u306e\u8907\u88fd\u3067\u3042\u308b"}]}, "item_5_select_19": {"attribute_name": "\u8457\u8005\u7248\u30d5\u30e9\u30b0", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_5_source_id_11": {"attribute_name": "\u66f8\u8a8c\u30ec\u30b3\u30fc\u30c9ID", "attribute_value_mlt": [{"subitem_source_identifier": "AN0018742X", "subitem_source_identifier_type": "NCID"}]}, "item_5_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "03875008", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "\u8457\u8005", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "\u9234\u6728, \u8ce2\u6cbb"}], "nameIdentifiers": [{"nameIdentifier": "44644", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u753a\u5c4b, \u4fee\u592a\u90ce"}], "nameIdentifiers": [{"nameIdentifier": "44645", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u7530\u4e2d, \u5553\u4ecb"}], "nameIdentifiers": [{"nameIdentifier": "44646", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "\u5742\u4e95\u7530, \u559c\u4e45"}], "nameIdentifiers": [{"nameIdentifier": "44647", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "\u30d5\u30a1\u30a4\u30eb\u60c5\u5831", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-07-30"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "9_0010.pdf", "filesize": [{"value": "645.8 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 645800.0, "url": {"label": "9_0010.pdf", "url": "https://niigata-u.repo.nii.ac.jp/record/3683/files/9_0010.pdf"}, "version_id": "e6c5d062-6c8a-463c-8006-382b3da03896"}]}, "item_keyword": {"attribute_name": "\u30ad\u30fc\u30ef\u30fc\u30c9", "attribute_value_mlt": [{"subitem_subject": "Experimental Stress Analysis", "subitem_subject_scheme": "Other"}, {"subitem_subject": "X-Ray Stress Measurement", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Material Testing", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Elastic Constant", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Residual Stress", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Ceramics", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Thermal Barrier Coating", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "\u8a00\u8a9e", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "\u8cc7\u6e90\u30bf\u30a4\u30d7", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "\u71b1\u906e\u3078\u3044\u30b8\u30eb\u30b3\u30cb\u30a2\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u306eX\u7dda\u7684\u5f3e\u6027\u5b9a\u6570\u3068\u6b8b\u7559\u5fdc\u529b\u5206\u5e03 \uff08\u5c0f\u7279\u96c6 \u5b9f\u9a13\u8a08\u6e2c\u6280\u8853\u306e\u65b0\u5c55\u958b\uff09", "item_titles": {"attribute_name": "\u30bf\u30a4\u30c8\u30eb", "attribute_value_mlt": [{"subitem_title": "\u71b1\u906e\u3078\u3044\u30b8\u30eb\u30b3\u30cb\u30a2\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u306eX\u7dda\u7684\u5f3e\u6027\u5b9a\u6570\u3068\u6b8b\u7559\u5fdc\u529b\u5206\u5e03 \uff08\u5c0f\u7279\u96c6 \u5b9f\u9a13\u8a08\u6e2c\u6280\u8853\u306e\u65b0\u5c55\u958b\uff09"}, {"subitem_title": "\u71b1\u906e\u3078\u3044\u30b8\u30eb\u30b3\u30cb\u30a2\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u306eX\u7dda\u7684\u5f3e\u6027\u5b9a\u6570\u3068\u6b8b\u7559\u5fdc\u529b\u5206\u5e03 \uff08\u5c0f\u7279\u96c6 \u5b9f\u9a13\u8a08\u6e2c\u6280\u8853\u306e\u65b0\u5c55\u958b\uff09", "subitem_title_language": "en"}]}, "item_type_id": "5", "owner": "1", "path": ["453/454", "423/424/425"], "permalink_uri": "http://hdl.handle.net/10191/5712", "pubdate": {"attribute_name": "\u516c\u958b\u65e5", "attribute_value": "2008-04-08"}, "publish_date": "2008-04-08", "publish_status": "0", "recid": "3683", "relation": {}, "relation_version_is_last": true, "title": ["\u71b1\u906e\u3078\u3044\u30b8\u30eb\u30b3\u30cb\u30a2\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u306eX\u7dda\u7684\u5f3e\u6027\u5b9a\u6570\u3068\u6b8b\u7559\u5fdc\u529b\u5206\u5e03 \uff08\u5c0f\u7279\u96c6 \u5b9f\u9a13\u8a08\u6e2c\u6280\u8853\u306e\u65b0\u5c55\u958b\uff09"], "weko_shared_id": null}
  1. 060 工学部
  2. 10 学術雑誌論文
  3. 10 査読済論文
  1. 0 資料タイプ別
  2. 01 学術雑誌論文

熱遮へいジルコニアコーティングのX線的弾性定数と残留応力分布 (小特集 実験計測技術の新展開)

http://hdl.handle.net/10191/5712
9d2b1469-5247-43fe-b3b5-e56a526d1f32
名前 / ファイル ライセンス アクション
9_0010.pdf 9_0010.pdf (645.8 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2008-04-08
タイトル
タイトル 熱遮へいジルコニアコーティングのX線的弾性定数と残留応力分布 (小特集 実験計測技術の新展開)
タイトル
言語 en
タイトル 熱遮へいジルコニアコーティングのX線的弾性定数と残留応力分布 (小特集 実験計測技術の新展開)
言語
言語 jpn
キーワード
主題Scheme Other
主題 Experimental Stress Analysis
キーワード
主題Scheme Other
主題 X-Ray Stress Measurement
キーワード
主題Scheme Other
主題 Material Testing
キーワード
主題Scheme Other
主題 Elastic Constant
キーワード
主題Scheme Other
主題 Residual Stress
キーワード
主題Scheme Other
主題 Ceramics
キーワード
主題Scheme Other
主題 Thermal Barrier Coating
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ journal article
その他のタイトル
その他のタイトル X-Ray Elastic Constants and Residual Stress Distributions of Zirconia Thermal Barrier Coating
著者 鈴木, 賢治

× 鈴木, 賢治

WEKO 44644

鈴木, 賢治

Search repository
町屋, 修太郎

× 町屋, 修太郎

WEKO 44645

町屋, 修太郎

Search repository
田中, 啓介

× 田中, 啓介

WEKO 44646

田中, 啓介

Search repository
坂井田, 喜久

× 坂井田, 喜久

WEKO 44647

坂井田, 喜久

Search repository
著者別名
識別子
識別子 44648
識別子Scheme WEKO
姓名
姓名 Suzuki, Kenji
著者別名
識別子
識別子 44649
識別子Scheme WEKO
姓名
姓名 Machiya, Syutaro
著者別名
識別子
識別子 44650
識別子Scheme WEKO
姓名
姓名 Tanaka, Keisuke
著者別名
識別子
識別子 44651
識別子Scheme WEKO
姓名
姓名 Sakaida, Yoshihisa
抄録
内容記述タイプ Abstract
内容記述 Accurate values of X-ray elastic constants are required for a reliable stress measurement of thermal barrier coating films (TBC films). In this paper, atmosphere and pressureless plasma sprayed TBC films were removed from substrates, then X-ray elastic constants of both TBC films were determained by using newly developed tensile jig. For the atmosphere plasma sprayed film, the value of the mechanical elastic constant was much smaller than the X-ray elastic constant owing to cracks or pores existing in the films. The X-ray elastic constant of the atmosphere plasma sprayed TBC film was nearly equal to that of the pressureless plasma sprayed film. This means that the X-ray elastic constants are little influenced by cracks or pores. Residual stress distributions in both films coated on the substrates were obtained. In the surface region with the depth up 60 μm, residual stresses of both films showed a drastic variation. This variation of the residual stresses was build up during rapid quenching and solidifying of the molten droplet. In deeper regions, residual stresses were nearly constant. These constant values of residual stresses are caused by the thermal strain mismatch between the TBC film and the substrate.
書誌情報 日本機械学会論文集. A編
en : 日本機械学会論文集. A編

巻 67, 号 655, p. 417-423, 発行日 2001-03
出版者
出版者 日本機械学会
ISSN
収録物識別子タイプ ISSN
収録物識別子 03875008
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN0018742X
権利
権利情報 日本機械学会 / 本文データは学会の許諾に基づくCiNiiからの複製である
著者版フラグ
値 publisher
異版である
関連タイプ isVersionOf
関連識別子
識別子タイプ URI
関連識別子 http://ci.nii.ac.jp/naid/110002369802
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 20:03:27.214961
Show All versions

Share

Mendeley CiteULike Twitter Facebook Print Addthis

Cite as

Export

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by CERN Data Centre & Invenio


Powered by CERN Data Centre & Invenio