{"created":"2021-03-01T06:07:25.530349+00:00","id":3660,"links":{},"metadata":{"_buckets":{"deposit":"0d82995d-26b9-4c46-9bdf-b92cfce03fbb"},"_deposit":{"id":"3660","owners":[],"pid":{"revision_id":0,"type":"depid","value":"3660"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00003660","sets":["432:477:478","453:454"]},"item_5_alternative_title_1":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Cervical range of motion and head movement trajectory during head inclination and turning tasks using electrical goniometer"}]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006-10","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"30","bibliographicPageStart":"21","bibliographicVolumeNumber":"13","bibliographic_titles":[{"bibliographic_title":"日本顎口腔機能学会雑誌"},{"bibliographic_title":"日本顎口腔機能学会雑誌","bibliographic_titleLang":"en"}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"There were little studies to measure cervical range of movement in Japan. In the present study, we applied an electrical goniometer for 27 of subjects to record the range of motion and movement trajectories of head inclination and turning tasks. In comparison of ranges with those of the previous studies, the range in pitch was found to be identical, however, that in roll was larger. The range was then analyzed for handedness, age and gender. In this study, no difference was found for handedness and gender; however, younger subjects showed significantly larger range in posterior, right and left directions. This suggests that range of motion in the anterior direction may be restricted by the morphological factor rather than muscles and/or soft tissues which could be affected with aging. Movement trajectories represented on the horizontal plane revealed movement instabilities in some of the asymptomatic subjects.","subitem_description_type":"Abstract"},{"subitem_description":"日本では頭頸部の関節可動域の研究は非常に少ない.電子式Goniometerを用いて,頭部屈曲運動および頭部回転運動時の関節可動域および運動軌跡を27名の被験者を対象に記録した.頸部関節可動域はこれまでの報告と比較し,前後方向ではアジアでの研究結果と一致していた.しかし,側方の可動域はこれまでの報告結果より大きな値を示した.関節可動域に関しては前後方向・左右方向で利き腕・年齢・男女間に群分けして比較し,利き腕・性別では群間に有意な差はなかったが,若年群では後方位・側方位で高齢群より明らかに大きな可動域が観察された.前方位に差がなかったことから前屈時の関節可動域の制限因子として加齢変化が影響する筋や軟組織ではなく,前屈運動時の形態的因子が関与すると推察される.頭部回転運動軌跡を水平面に投影したところ,特に頸部に症状を訴えない被験者にも運動が円滑でない例が認められた.","subitem_description_type":"Abstract"}]},"item_5_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"44464","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Saito, Yonezo"}]},{"nameIdentifiers":[{"nameIdentifier":"44465","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Hirano, Hidetoshi"}]},{"nameIdentifiers":[{"nameIdentifier":"44466","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Kurose, Masayuki"}]},{"nameIdentifiers":[{"nameIdentifier":"44467","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Yamada, Yoshiaki"}]}]},"item_5_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本顎口腔機能学会"}]},"item_5_relation_31":{"attribute_name":"異版である","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"http://ci.nii.ac.jp/naid/110006153942","subitem_relation_type_select":"URI"}}]},"item_5_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"日本顎口腔機能学会"},{"subitem_rights":"本文データは学協会の許諾に基づきCiNiiから複製したものである"}]},"item_5_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_5_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN1047134X","subitem_source_identifier_type":"NCID"}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13409085","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"齋藤, 米蔵"}],"nameIdentifiers":[{"nameIdentifier":"44460","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"平野, 秀利"}],"nameIdentifiers":[{"nameIdentifier":"44461","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"黒瀬, 雅之"}],"nameIdentifiers":[{"nameIdentifier":"44462","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山田, 好秋"}],"nameIdentifiers":[{"nameIdentifier":"44463","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-07-30"}],"displaytype":"detail","filename":"110006153942.pdf","filesize":[{"value":"1.1 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"110006153942.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/3660/files/110006153942.pdf"},"version_id":"d117750c-8df3-4b11-9445-e92d85cd46cc"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"electrical goniometer","subitem_subject_scheme":"Other"},{"subitem_subject":"head movement","subitem_subject_scheme":"Other"},{"subitem_subject":"trunk drift","subitem_subject_scheme":"Other"},{"subitem_subject":"cervical range of motion","subitem_subject_scheme":"Other"},{"subitem_subject":"電子式Goniometer","subitem_subject_scheme":"Other"},{"subitem_subject":"頸部関節可動域","subitem_subject_scheme":"Other"},{"subitem_subject":"頭部回転運動","subitem_subject_scheme":"Other"},{"subitem_subject":"体幹動揺","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"電子式Goniometerを用いた頭部屈曲・回転運動時の関節可動域の解析と運動軌跡の観察","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"電子式Goniometerを用いた頭部屈曲・回転運動時の関節可動域の解析と運動軌跡の観察"},{"subitem_title":"電子式Goniometerを用いた頭部屈曲・回転運動時の関節可動域の解析と運動軌跡の観察","subitem_title_language":"en"}]},"item_type_id":"5","owner":"1","path":["454","478"],"pubdate":{"attribute_name":"公開日","attribute_value":"2009-08-31"},"publish_date":"2009-08-31","publish_status":"0","recid":"3660","relation_version_is_last":true,"title":["電子式Goniometerを用いた頭部屈曲・回転運動時の関節可動域の解析と運動軌跡の観察"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-15T03:36:47.444455+00:00"}