{"created":"2021-03-01T06:07:08.842272+00:00","id":3392,"links":{},"metadata":{"_buckets":{"deposit":"10090012-20df-4f55-9b6f-a1739d8ae78c"},"_deposit":{"id":"3392","owners":[],"pid":{"revision_id":0,"type":"depid","value":"3392"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00003392","sets":["423:424:425","453:454"]},"item_5_alternative_title_1":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"The Experimental Results for Polarimetric Diffraction Tomography"}]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1996-05","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"5","bibliographicPageEnd":"305","bibliographicPageStart":"302","bibliographicVolumeNumber":"J79-B-II","bibliographic_titles":[{"bibliographic_title":"電子情報通信学会論文誌. B-II, 通信II"},{"bibliographic_title":"電子情報通信学会論文誌. B-II, 通信II","bibliographic_titleLang":"en"}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"co-pol成分とcross-pol成分を使ったDiffraction Tomographyに関する実験を行い,cross-pol成分によって物体のエッジ情報が強調されることを示した.また,15%の比誘電率差でも再構成が可能であった.","subitem_description_type":"Abstract"}]},"item_5_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"42546","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Inomata, Kenji"}]},{"nameIdentifiers":[{"nameIdentifier":"19","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Yamaguchi, Yoshio"}]},{"nameIdentifiers":[{"nameIdentifier":"50","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Yamada, Hiroyoshi"}]}]},"item_5_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"電子情報通信学会"}]},"item_5_relation_31":{"attribute_name":"異版である","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.ieice.org/jpn/trans_online/","subitem_relation_type_select":"URI"}}]},"item_5_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"copyright©1996 IEICE"}]},"item_5_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_5_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN10071159","subitem_source_identifier_type":"NCID"}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"09151885","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"猪又, 憲治"}],"nameIdentifiers":[{"nameIdentifier":"42543","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山口, 芳雄"}],"nameIdentifiers":[{"nameIdentifier":"19","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山田, 寛喜"}],"nameIdentifiers":[{"nameIdentifier":"50","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-07-30"}],"displaytype":"detail","filename":"J79-B-2-5_ 302-305.pdf","filesize":[{"value":"411.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"J79-B-2-5_ 302-305.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/3392/files/J79-B-2-5_ 302-305.pdf"},"version_id":"0f8055a2-4a6f-4132-81a3-caa22a5b13f1"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Diffraction Tomography","subitem_subject_scheme":"Other"},{"subitem_subject":"フィルタ補正逆伝搬法","subitem_subject_scheme":"Other"},{"subitem_subject":"偏波","subitem_subject_scheme":"Other"},{"subitem_subject":"Cross-pol","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"偏波を考慮したDiffraction Tomography における再構成","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"偏波を考慮したDiffraction Tomography における再構成"}]},"item_type_id":"5","owner":"1","path":["454","425"],"pubdate":{"attribute_name":"公開日","attribute_value":"2009-04-14"},"publish_date":"2009-04-14","publish_status":"0","recid":"3392","relation_version_is_last":true,"title":["偏波を考慮したDiffraction Tomography における再構成"],"weko_creator_id":"1","weko_shared_id":2},"updated":"2022-12-15T03:36:31.179369+00:00"}