{"created":"2021-03-01T06:38:04.305531+00:00","id":31846,"links":{},"metadata":{"_buckets":{"deposit":"6ef28a3e-13db-4e5f-9fcb-44d9e50a6e76"},"_deposit":{"id":"31846","owners":[],"pid":{"revision_id":0,"type":"depid","value":"31846"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00031846","sets":["453:457","468:1817:1833"]},"item_8_alternative_title_1":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Study on the Capture Ratio of the Range Hood Fan in the House Kitchen : Part 1 Change of Capture Ratio of Cross Flow over the IH Range and Gas Range"}]},"item_8_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2007-07","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"200","bibliographicPageStart":"197","bibliographicVolumeNumber":"50","bibliographic_titles":[{"bibliographic_title":"日本建築学会北陸支部研究報告集"},{"bibliographic_title":"日本建築学会北陸支部研究報告集","bibliographic_titleLang":"en"}]}]},"item_8_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"本報では、家庭用のIHレンジとガスレンジを対象とし、横風による擾乱がIHレンジとガスレンジの廃気捕集率に与える影響を比較し、IHレンジとガスレンジの特性の違いを明らかにした。擾乱を与えた場合、排気風量が200m^3/hにおける廃気捕集率は、フード下端高さ800mm、600mmともに、風速が遅い場合はIHレンジで高く、風速が速<なるにつれてガスレンジが高くなる。","subitem_description_type":"Abstract"}]},"item_8_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"174095","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Akabayashi, Shin-ichi"}]},{"nameIdentifiers":[{"nameIdentifier":"174096","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Sakaguchi, Jun"}]},{"nameIdentifiers":[{"nameIdentifier":"174097","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Tomioka, Seiko"}]},{"nameIdentifiers":[{"nameIdentifier":"174098","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Ishiyama, Yohei"}]}]},"item_8_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本建築学会"}]},"item_8_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"社団法人日本建築学会"}]},"item_8_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_8_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00188761","subitem_source_identifier_type":"NCID"}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"03859622","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"赤林, 伸一"}],"nameIdentifiers":[{"nameIdentifier":"174091","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"坂口, 淳"}],"nameIdentifiers":[{"nameIdentifier":"174092","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"富岡, 誠子"}],"nameIdentifiers":[{"nameIdentifier":"174093","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"石山, 洋平"}],"nameIdentifiers":[{"nameIdentifier":"174094","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-08-27"}],"displaytype":"detail","filename":"ZD_50_197-200.pdf","filesize":[{"value":"1.2 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"ZD_50_197-200.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/31846/files/ZD_50_197-200.pdf"},"version_id":"d5f94a99-bfcb-4a41-b171-2d539038bcbe"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Capture Ratio","subitem_subject_scheme":"Other"},{"subitem_subject":"Cross Flow","subitem_subject_scheme":"Other"},{"subitem_subject":"IH Cooking Heater","subitem_subject_scheme":"Other"},{"subitem_subject":"Gas Range","subitem_subject_scheme":"Other"},{"subitem_subject":"廃気捕集率","subitem_subject_scheme":"Other"},{"subitem_subject":"横風","subitem_subject_scheme":"Other"},{"subitem_subject":"IHレンジ","subitem_subject_scheme":"Other"},{"subitem_subject":"ガスレンジ","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"住宅用厨房を対象とした排気フードの廃気捕集率に関する研究 : その1 レンジ上に横風を与えた場合の捕集率の変化","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"住宅用厨房を対象とした排気フードの廃気捕集率に関する研究 : その1 レンジ上に横風を与えた場合の捕集率の変化"},{"subitem_title":"住宅用厨房を対象とした排気フードの廃気捕集率に関する研究 : その1 レンジ上に横風を与えた場合の捕集率の変化","subitem_title_language":"en"}]},"item_type_id":"8","owner":"1","path":["457","1833"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-06-05"},"publish_date":"2012-06-05","publish_status":"0","recid":"31846","relation_version_is_last":true,"title":["住宅用厨房を対象とした排気フードの廃気捕集率に関する研究 : その1 レンジ上に横風を与えた場合の捕集率の変化"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-15T04:02:14.414160+00:00"}