{"created":"2021-03-01T06:06:50.251897+00:00","id":3098,"links":{},"metadata":{"_buckets":{"deposit":"e6d1cc32-fa36-487e-813f-3b3eef039295"},"_deposit":{"id":"3098","owners":[],"pid":{"revision_id":0,"type":"depid","value":"3098"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00003098","sets":["423:424:425","453:454"]},"item_5_alternative_title_1":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Development of Laser Therapy Apparatus using Minute Spot Scanning Method : Wide Range Laser Scanning using Shrink Fitter"}]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006-02","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"265","bibliographicPageStart":"260","bibliographicVolumeNumber":"72","bibliographic_titles":[{"bibliographic_title":"精密工学会誌論文集"},{"bibliographic_title":"精密工学会誌論文集","bibliographic_titleLang":"en"}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"To remove unwanted pigments in the skin laser light is irradiated on the pigmented lesion. Melanin, locally existing in skin, selectively absorbs the laser light. At present, the laser guns used in dermatology are manually operated and their laser spots are as large as 3 to 7mm in diameter. It is thought that normal tissues, which don't contain melanin so much, are hardly damaged by the laser irradiation. But in reality, terrible burns appear after laser irradiation even in the normal tissue. We have developed a new type of laser apparatus for removing pigmented lesions with laser focusing and laser scanning technology. The fθlens unit assembled by a shrink fitter can focus the laser beam well over a wide scanning width. Thus, the intensity of the focused laser beam became high enough even with a low-power laser oscillator. The focused laser irradiation lead also to another advantage. The cooling rate of the lesion, whose temperature rises over a given point by the focused laser beam, was increased. The effect of the focused laser irradiation on the pigmentation therapy was experimentally examined with the developed apparatus.","subitem_description_type":"Abstract"}]},"item_5_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"58","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Nitta, Isami"}]},{"nameIdentifiers":[{"nameIdentifier":"40789","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Kan, Yasushi"}]},{"nameIdentifiers":[{"nameIdentifier":"40790","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Kanno, Akihiro"}]},{"nameIdentifiers":[{"nameIdentifier":"40791","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Maruyama, Tomohiro"}]},{"nameIdentifiers":[{"nameIdentifier":"40792","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Maeda, Yoshitaka"}]}]},"item_5_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"精密工学会"}]},"item_5_relation_31":{"attribute_name":"異版である","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"http://ci.nii.ac.jp/naid/110004028577","subitem_relation_type_select":"URI"}}]},"item_5_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"本文データは学協会の許諾に基づきCiNiiから複製したものである"}]},"item_5_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_5_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11966630","subitem_source_identifier_type":"NCID"}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13488724","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"新田, 勇"}],"nameIdentifiers":[{"nameIdentifier":"58","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"菅, 康志"}],"nameIdentifiers":[{"nameIdentifier":"40784","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"菅野, 明宏"}],"nameIdentifiers":[{"nameIdentifier":"40785","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"丸山, 友裕"}],"nameIdentifiers":[{"nameIdentifier":"40786","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"前田, 宜俊"}],"nameIdentifiers":[{"nameIdentifier":"40787","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-07-30"}],"displaytype":"detail","filename":"110004028577.pdf","filesize":[{"value":"1.1 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"110004028577.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/3098/files/110004028577.pdf"},"version_id":"91c718d3-8390-40e7-83fc-390b51eb3a47"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"laser therapy apparatus","subitem_subject_scheme":"Other"},{"subitem_subject":"YAG laser","subitem_subject_scheme":"Other"},{"subitem_subject":"SHG","subitem_subject_scheme":"Other"},{"subitem_subject":"shrink fitter","subitem_subject_scheme":"Other"},{"subitem_subject":"laser scanning","subitem_subject_scheme":"Other"},{"subitem_subject":"melanin","subitem_subject_scheme":"Other"},{"subitem_subject":"fθ lens","subitem_subject_scheme":"Other"},{"subitem_subject":"FEM","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"微細スポット走査法を用いたレーザ治療装置の開発 : シュリンクフィッタを用いたレーザ広範囲走査","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"微細スポット走査法を用いたレーザ治療装置の開発 : シュリンクフィッタを用いたレーザ広範囲走査"},{"subitem_title":"微細スポット走査法を用いたレーザ治療装置の開発 : シュリンクフィッタを用いたレーザ広範囲走査","subitem_title_language":"en"}]},"item_type_id":"5","owner":"1","path":["454","425"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-11-28"},"publish_date":"2013-11-28","publish_status":"0","recid":"3098","relation_version_is_last":true,"title":["微細スポット走査法を用いたレーザ治療装置の開発 : シュリンクフィッタを用いたレーザ広範囲走査"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-15T03:36:15.990550+00:00"}