{"created":"2021-03-01T06:06:49.548464+00:00","id":3087,"links":{},"metadata":{"_buckets":{"deposit":"0428f898-b016-43ac-af0c-aa404609e201"},"_deposit":{"id":"3087","owners":[],"pid":{"revision_id":0,"type":"depid","value":"3087"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00003087","sets":["423:424:425","453:454"]},"item_5_alternative_title_1":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Optical & Non-contact Data-transmission System of Rotating Spindle Temperature by Adopting One-chip Micro-controller (2nd Report) : Measurement Accuracy"}]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2003-10","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"10","bibliographicPageEnd":"1486","bibliographicPageStart":"1480","bibliographicVolumeNumber":"69","bibliographic_titles":[{"bibliographic_title":"精密工学会誌"},{"bibliographic_title":"精密工学会誌","bibliographic_titleLang":"en"}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper deals with the measurement accuracy superior than 0.05〜0.1℃ for 0〜50℃ range of the developed data-transmission system. To realize the measurement accuracy best, it is necessary to satisfy several conditions; namely the calibration of the system should be carried out under several different temperatures or more and under sufficiently insulated condition, the output of all channels should be compensated based upon the temperature of electric circuit board and the warm-up operation for electric parts is needed.","subitem_description_type":"Abstract"}]},"item_5_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"40695","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Nagai, Yutaka"}]},{"nameIdentifiers":[{"nameIdentifier":"40696","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Yokoyama, Kazuhiro"}]},{"nameIdentifiers":[{"nameIdentifier":"39","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Suzuki, Takamasa"}]},{"nameIdentifiers":[{"nameIdentifier":"40698","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Kodera, Takehiko"}]}]},"item_5_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"精密工学会"}]},"item_5_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"info:doi/10.2493/jjspe.69.1480","subitem_relation_type_select":"DOI"}}]},"item_5_relation_31":{"attribute_name":"異版である","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"http://ci.nii.ac.jp/naid/110001373509","subitem_relation_type_select":"URI"}}]},"item_5_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© 2003 精密工学会"},{"subitem_rights":"本文データは学協会の許諾に基づきCiNiiから複製したものである"}]},"item_5_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_5_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN1003250X","subitem_source_identifier_type":"NCID"}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"09120289","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"永井, 豊"}],"nameIdentifiers":[{"nameIdentifier":"40691","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"横山, 和宏"}],"nameIdentifiers":[{"nameIdentifier":"40692","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鈴木, 孝昌"}],"nameIdentifiers":[{"nameIdentifier":"39","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小寺, 岳彦"}],"nameIdentifiers":[{"nameIdentifier":"40694","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-07-30"}],"displaytype":"detail","filename":"110001373509.pdf","filesize":[{"value":"783.8 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"110001373509.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/3087/files/110001373509.pdf"},"version_id":"547697ae-0393-4d93-bb44-120844479317"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"optical system","subitem_subject_scheme":"Other"},{"subitem_subject":"data-transmission","subitem_subject_scheme":"Other"},{"subitem_subject":"rotating spindle","subitem_subject_scheme":"Other"},{"subitem_subject":"temperature","subitem_subject_scheme":"Other"},{"subitem_subject":"micro-controller","subitem_subject_scheme":"Other"},{"subitem_subject":"accuracy","subitem_subject_scheme":"Other"},{"subitem_subject":"calibration","subitem_subject_scheme":"Other"},{"subitem_subject":"compensation","subitem_subject_scheme":"Other"},{"subitem_subject":"thermo-couple","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"ワンチップ・マイクロコントローラを用いた回転軸温度情報の光学式非接触データ伝送システムの研究(第2報) : 測定精度","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"ワンチップ・マイクロコントローラを用いた回転軸温度情報の光学式非接触データ伝送システムの研究(第2報) : 測定精度"},{"subitem_title":"ワンチップ・マイクロコントローラを用いた回転軸温度情報の光学式非接触データ伝送システムの研究(第2報) : 測定精度","subitem_title_language":"en"}]},"item_type_id":"5","owner":"1","path":["454","425"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-06-20"},"publish_date":"2014-06-20","publish_status":"0","recid":"3087","relation_version_is_last":true,"title":["ワンチップ・マイクロコントローラを用いた回転軸温度情報の光学式非接触データ伝送システムの研究(第2報) : 測定精度"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-15T03:36:16.248737+00:00"}