{"created":"2021-03-01T06:06:49.351502+00:00","id":3084,"links":{},"metadata":{"_buckets":{"deposit":"a1c7eb3d-70aa-4cd8-9651-4de32ba34546"},"_deposit":{"id":"3084","owners":[],"pid":{"revision_id":0,"type":"depid","value":"3084"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00003084","sets":["423:424:425","453:454"]},"item_5_alternative_title_1":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Development of Multi-Polygon Laser Scanner Using a Shrink Fitter"}]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"263","bibliographicPageStart":"258","bibliographicVolumeNumber":"74","bibliographic_titles":[{"bibliographic_title":"精密工学会誌"},{"bibliographic_title":"精密工学会誌","bibliographic_titleLang":"en"}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A multi-polygon laser scanner system has been developed by using a shrink fitter, in order to produce a new laser direct imager having an ultra wide scanning width and high resolution. The shrink fitter is a new machine element which is cylindrical-shaped and made of plastic materials. This is developed to connect the two machine elements that have different thermal expansion coefficients with a shrinkage fit. In this joining method, the optical axes of the lenses coincide with the axis of the lens-barrel. The positioning accuracy of the lenses in the lens-barrel did not change at any temperature since the shrink fitter sufficiently expanded or contracted in the radial direction to compensate the change in interference. Therefore, the beam spot became very fine all over the wide scanning width at elevated temperature. In this study, we applied laser scanner units using the shrink fitter to the multi-polygon system, which arranged these units in a line. The performance of the new laser direct imaging system was confirmed experimentally.","subitem_description_type":"Abstract"}]},"item_5_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"40673","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Kanno, Akihiro"}]},{"nameIdentifiers":[{"nameIdentifier":"58","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Nitta, Isami"}]},{"nameIdentifiers":[{"nameIdentifier":"40675","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Komata, Kimio"}]},{"nameIdentifiers":[{"nameIdentifier":"40676","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Iguchi, Satoshi"}]}]},"item_5_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"精密工学会"}]},"item_5_relation_31":{"attribute_name":"異版である","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"http://ci.nii.ac.jp/naid/110006647629","subitem_relation_type_select":"URI"}}]},"item_5_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"本文データは学協会の許諾に基づきCiNiiから複製したものである"}]},"item_5_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_5_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN1003250X","subitem_source_identifier_type":"NCID"}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"09120289","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"菅野, 明宏"}],"nameIdentifiers":[{"nameIdentifier":"40669","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"新田, 勇"}],"nameIdentifiers":[{"nameIdentifier":"58","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"小俣, 公夫"}],"nameIdentifiers":[{"nameIdentifier":"40671","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"井口, 敏"}],"nameIdentifiers":[{"nameIdentifier":"40672","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-07-30"}],"displaytype":"detail","filename":"110006647629.pdf","filesize":[{"value":"2.1 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"110006647629.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/3084/files/110006647629.pdf"},"version_id":"a9a16020-b4c6-4d18-97e0-cef2f168c4e1"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"optical lens","subitem_subject_scheme":"Other"},{"subitem_subject":"lens-barrel","subitem_subject_scheme":"Other"},{"subitem_subject":"laser scanner","subitem_subject_scheme":"Other"},{"subitem_subject":"shrink fitter","subitem_subject_scheme":"Other"},{"subitem_subject":"laser direct imaging","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"シュリンクフィッタを用いたマルチポリゴン方式レーザ走査装置の開発","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"シュリンクフィッタを用いたマルチポリゴン方式レーザ走査装置の開発"},{"subitem_title":"シュリンクフィッタを用いたマルチポリゴン方式レーザ走査装置の開発","subitem_title_language":"en"}]},"item_type_id":"5","owner":"1","path":["454","425"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-11-27"},"publish_date":"2013-11-27","publish_status":"0","recid":"3084","relation_version_is_last":true,"title":["シュリンクフィッタを用いたマルチポリゴン方式レーザ走査装置の開発"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-15T03:36:16.336443+00:00"}