WEKO3
アイテム
{"_buckets": {"deposit": "cee9afec-a3d9-4974-a77e-082ca267e234"}, "_deposit": {"id": "2939", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "2939"}, "status": "published"}, "_oai": {"id": "oai:niigata-u.repo.nii.ac.jp:00002939", "sets": ["454", "425"]}, "item_5_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2009-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "Special Issue", "bibliographicPageEnd": "166", "bibliographicPageStart": "162", "bibliographicVolumeNumber": "9", "bibliographic_titles": [{"bibliographic_title": "実験力学"}, {"bibliographic_title": "実験力学", "bibliographic_titleLang": "en"}]}]}, "item_5_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The purpose of the present study is to develop a direct and accurate method for measuring knee kinematics by using single-plane fluoroscopy. The 3-dimensional (3D) position of the bone (in other words, the 6 degree-of-freedom (DOF) parameters) was recovered by matching the digitally reconstructed radiographs (DRRs) generated from the 3D volume model of the bone on the basis of the fluoroscopic image. The root-mean-square error (RMSE) of the overall rotation parameters was within 2.1 degrees. For the translation parameters RMSE took its maximal value of 3.6 mm in the out-of-plane direction. This indicates that the present method has potential for clinical application.", "subitem_description_type": "Abstract"}]}, "item_5_publisher_7": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本実験力学会"}]}, "item_5_relation_31": {"attribute_name": "異版である", "attribute_value_mlt": [{"subitem_relation_type": "isVersionOf", "subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.jstage.jst.go.jp/article/jjsem/9/Special_Issue/9_Special_Issue_s162/_pdf", "subitem_relation_type_select": "URI"}}]}, "item_5_rights_15": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "Copyright (C) 2009 JSEM"}, {"subitem_rights": "コンテンツのご利用は著作権法の範囲内でお願いします。"}, {"subitem_rights": "本文データは学協会の許諾に基づきJ-Stageから複製したものである"}]}, "item_5_select_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_5_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AA11822914", "subitem_source_identifier_type": "NCID"}]}, "item_5_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "13464930", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Tanaka, Nobuaki"}], "nameIdentifiers": [{"nameIdentifier": "39988", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Odagawa, Ken-ichi"}], "nameIdentifiers": [{"nameIdentifier": "39989", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sakamoto, Makoto"}], "nameIdentifiers": [{"nameIdentifier": "39990", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Tanabe, Yuji"}], "nameIdentifiers": [{"nameIdentifier": "39991", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-07-30"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "9_SP_162-166.pdf", "filesize": [{"value": "1.2 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 1200000.0, "url": {"label": "9_SP_162-166.pdf", "url": "https://niigata-u.repo.nii.ac.jp/record/2939/files/9_SP_162-166.pdf"}, "version_id": "91a718a6-d4ac-45e1-9217-f6e5a64ae2c0"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "Biomechanics", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Knee Kinematics", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Image Registration", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Single-Plane Fluoroscopy", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Orthopaedics", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Image-based Matching for Natural Knee Kinematics Measurement Using Single-Plane Fluoroscopy", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Image-based Matching for Natural Knee Kinematics Measurement Using Single-Plane Fluoroscopy"}, {"subitem_title": "Image-based Matching for Natural Knee Kinematics Measurement Using Single-Plane Fluoroscopy", "subitem_title_language": "en"}]}, "item_type_id": "5", "owner": "1", "path": ["454", "425"], "permalink_uri": "http://hdl.handle.net/10191/26377", "pubdate": {"attribute_name": "公開日", "attribute_value": "2014-03-17"}, "publish_date": "2014-03-17", "publish_status": "0", "recid": "2939", "relation": {}, "relation_version_is_last": true, "title": ["Image-based Matching for Natural Knee Kinematics Measurement Using Single-Plane Fluoroscopy"], "weko_shared_id": null}
Image-based Matching for Natural Knee Kinematics Measurement Using Single-Plane Fluoroscopy
http://hdl.handle.net/10191/26377
http://hdl.handle.net/10191/26377c2e73d3e-0075-413b-9a23-96c11eb2d43c
名前 / ファイル | ライセンス | アクション |
---|---|---|
9_SP_162-166.pdf (1.2 MB)
|
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2014-03-17 | |||||
タイトル | ||||||
タイトル | Image-based Matching for Natural Knee Kinematics Measurement Using Single-Plane Fluoroscopy | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Image-based Matching for Natural Knee Kinematics Measurement Using Single-Plane Fluoroscopy | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Biomechanics | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Knee Kinematics | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Image Registration | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Single-Plane Fluoroscopy | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | Orthopaedics | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
著者 |
Tanaka, Nobuaki
× Tanaka, Nobuaki× Odagawa, Ken-ichi× Sakamoto, Makoto× Tanabe, Yuji |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The purpose of the present study is to develop a direct and accurate method for measuring knee kinematics by using single-plane fluoroscopy. The 3-dimensional (3D) position of the bone (in other words, the 6 degree-of-freedom (DOF) parameters) was recovered by matching the digitally reconstructed radiographs (DRRs) generated from the 3D volume model of the bone on the basis of the fluoroscopic image. The root-mean-square error (RMSE) of the overall rotation parameters was within 2.1 degrees. For the translation parameters RMSE took its maximal value of 3.6 mm in the out-of-plane direction. This indicates that the present method has potential for clinical application. | |||||
書誌情報 |
実験力学 en : 実験力学 巻 9, 号 Special Issue, p. 162-166, 発行日 2009-09 |
|||||
出版者 | ||||||
出版者 | 日本実験力学会 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 13464930 | |||||
書誌レコードID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA11822914 | |||||
権利 | ||||||
権利情報 | Copyright (C) 2009 JSEM | |||||
権利 | ||||||
権利情報 | コンテンツのご利用は著作権法の範囲内でお願いします。 | |||||
権利 | ||||||
権利情報 | 本文データは学協会の許諾に基づきJ-Stageから複製したものである | |||||
著者版フラグ | ||||||
値 | publisher | |||||
異版である | ||||||
関連タイプ | isVersionOf | |||||
識別子タイプ | URI | |||||
関連識別子 | https://www.jstage.jst.go.jp/article/jjsem/9/Special_Issue/9_Special_Issue_s162/_pdf |