{"created":"2021-03-01T06:06:39.623246+00:00","id":2923,"links":{},"metadata":{"_buckets":{"deposit":"f07de675-908b-4fe6-a836-6178491738fb"},"_deposit":{"id":"2923","owners":[],"pid":{"revision_id":0,"type":"depid","value":"2923"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00002923","sets":["154:501:502","453:454"]},"item_5_alternative_title_1":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"In-Situ Stress Measurement of Bond Coatings at High Temperature by High-Energy Synchrotron X-Rays"}]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2003-07","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"7","bibliographicPageEnd":"763","bibliographicPageStart":"756","bibliographicVolumeNumber":"52","bibliographic_titles":[{"bibliographic_title":"材料"},{"bibliographic_title":"材料","bibliographic_titleLang":"en"}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"High-energy X-rays from a synchrotron radiation source, SPring-8, are available to obtain the microstructural information at deep positions inside the materials, because of its large penetration depth. Using the high-energy X-rays with an energy level of about 73keV, the internal stress in the bond coating was measured through the top coating in the thermal barrier coatings (TBCs) which consisted of a zirconia top coat with thickness of 0.24mm and a NiCoCrAlY bond coat with thickness of 0.2mm. A furnace, which could heat up the specimen up to 1473K was developed for the purpose of the in-situ stress measurement of the TBC in the goniometer at Beam Line BL02B1 of SPring-8. The diffraction of Ni_3Al-311 from the bond coat obtained through the top coat with about 0.24mm thickness was strong enough for stress determination. The internal stress in the bond coating was measured at the room temperature, 773K, 1073K and 1373K. The internal stress in the bond coat at a room temperature was tensile, and it was decreased with increase in temperature. At 1073K or higher, the internal stress in the bond coat was released due to softening of the bond coat. The change of internal stresses in the bond coat with temperatures was explained by thermal mismatch of expansion between top and bond coats.","subitem_description_type":"Abstract"}]},"item_5_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"39838","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Suzuki, Kenji"}]},{"nameIdentifiers":[{"nameIdentifier":"39839","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Tanaka, Keisuke"}]},{"nameIdentifiers":[{"nameIdentifier":"39840","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Akiniwa, Yoshiaki"}]},{"nameIdentifiers":[{"nameIdentifier":"39841","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Kawamura, Masashi"}]},{"nameIdentifiers":[{"nameIdentifier":"39842","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Nishio, Kozi"}]},{"nameIdentifiers":[{"nameIdentifier":"39843","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Okado, Hideki"}]}]},"item_5_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本材料学会"}]},"item_5_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_5_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN00096175","subitem_source_identifier_type":"NCID"}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"05145163","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"鈴木, 賢治"}],"nameIdentifiers":[{"nameIdentifier":"39832","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"田中, 啓介"}],"nameIdentifiers":[{"nameIdentifier":"39833","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"秋庭, 義明"}],"nameIdentifiers":[{"nameIdentifier":"39834","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"川村, 昌志"}],"nameIdentifiers":[{"nameIdentifier":"39835","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"西尾, 光司"}],"nameIdentifiers":[{"nameIdentifier":"39836","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"尾角, 英毅"}],"nameIdentifiers":[{"nameIdentifier":"39837","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-07-30"}],"displaytype":"detail","filename":"ZQ_52(7)_756-763.pdf","filesize":[{"value":"1.3 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"ZQ_52(7)_756-763.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/2923/files/ZQ_52(7)_756-763.pdf"},"version_id":"1f54e4fa-1dc0-4de1-96e6-d87301e8e2d0"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Thermal barrier coating","subitem_subject_scheme":"Other"},{"subitem_subject":"Residual stress","subitem_subject_scheme":"Other"},{"subitem_subject":"Synchrotron radiations","subitem_subject_scheme":"Other"},{"subitem_subject":"In-situ stress measurement","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"高エネルギー放射光による遮熱コーティングのボンドコートの高温その場応力測定","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"高エネルギー放射光による遮熱コーティングのボンドコートの高温その場応力測定"},{"subitem_title":"高エネルギー放射光による遮熱コーティングのボンドコートの高温その場応力測定","subitem_title_language":"en"}]},"item_type_id":"5","owner":"1","path":["454","502"],"pubdate":{"attribute_name":"公開日","attribute_value":"2012-04-05"},"publish_date":"2012-04-05","publish_status":"0","recid":"2923","relation_version_is_last":true,"title":["高エネルギー放射光による遮熱コーティングのボンドコートの高温その場応力測定"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-15T03:36:09.162050+00:00"}