{"_buckets": {"deposit": "b0d470b1-d966-4328-a437-e135d961f412"}, "_deposit": {"id": "2744", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "2744"}, "status": "published"}, "_oai": {"id": "oai:niigata-u.repo.nii.ac.jp:00002744", "sets": ["454", "425"]}, "item_5_alternative_title_1": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Analysis of Surface Electromyogram by the Geometrical Relationship of Prediction Error Vectors"}]}, "item_5_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1986-04", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "85", "bibliographicPageStart": "80", "bibliographicVolumeNumber": "24", "bibliographic_titles": [{"bibliographic_title": "医用電子と生体工学"}, {"bibliographic_title": "医用電子と生体工学", "bibliographic_titleLang": "en"}]}]}, "item_5_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "It has been reported that the mode of muscle activity is concerned with the power spectrum pattern of surface electromyogram (EMG), in so far as the signal is steadily ergodic in the stochastic process. In this paper, a new deterministic method is proposed for characterization of the non-stationary EMG which varies dynamically in time. An AR (auto-regressive) model is suitable to explain the almost periodical EMG. When the parameters of this model are calculated by the least square estimate (LSE), it is important that the (i+1) th order of forward and the (i) th order of backward prediction error vectors be orthogonal to each other. Therefore, the non-stationariness of EMG is characterized from the looseness of the orthogonality, if these vectors at any interval are obtained as the outputs from the standard filter (SDF), which is defined in a stationary interval by the LSE. Practically, {JFBEO(i)}, which resembles the similarity function, is used for characterization. When an SDF was prepared with the masticatory EMG during the maximum clenching, decrease in the order of AR model appeared for 50%, 25% clenching. At the onset and the ending phase of EMG during the tapping movement, the order also decreased gradually toward the silent phase. The physiological meaning of the order has not yet been clarified, but this method may be useful to understanding the transition period of EMG, which is concerned with excitation and inhibition.", "subitem_description_type": "Abstract"}]}, "item_5_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "38812", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Kiryu, Tohru"}]}, {"nameIdentifiers": [{"nameIdentifier": "38813", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Iijima, Taizo"}]}, {"nameIdentifiers": [{"nameIdentifier": "38814", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Saitoh, Yoshiaki"}]}, {"nameIdentifiers": [{"nameIdentifier": "38815", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Yamaga, Takuo"}]}, {"nameIdentifiers": [{"nameIdentifier": "38816", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Ishioka, Kiyoshi"}]}]}, "item_5_publisher_7": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本ME学会"}]}, "item_5_select_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_5_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00016981", "subitem_source_identifier_type": "NCID"}]}, "item_5_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "00213292", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "木竜, 徹"}], "nameIdentifiers": [{"nameIdentifier": "38807", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "飯島, 泰蔵"}], "nameIdentifiers": [{"nameIdentifier": "38808", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "斉藤, 義明"}], "nameIdentifiers": [{"nameIdentifier": "38809", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山鹿, 卓郎"}], "nameIdentifiers": [{"nameIdentifier": "38810", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "石岡, 靖"}], "nameIdentifiers": [{"nameIdentifier": "38811", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-07-29"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "24_2_80-85.pdf", "filesize": [{"value": "926.5 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 926500.0, "url": {"label": "24_2_80-85.pdf", "url": "https://niigata-u.repo.nii.ac.jp/record/2744/files/24_2_80-85.pdf"}, "version_id": "efc7177e-d34e-4909-b925-a2801dcb3689"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "予測誤差の幾何学的関係による表面筋電図解析", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "予測誤差の幾何学的関係による表面筋電図解析"}, {"subitem_title": "予測誤差の幾何学的関係による表面筋電図解析", "subitem_title_language": "en"}]}, "item_type_id": "5", "owner": "1", "path": ["454", "425"], "permalink_uri": "http://hdl.handle.net/10191/20185", "pubdate": {"attribute_name": "公開日", "attribute_value": "2012-10-24"}, "publish_date": "2012-10-24", "publish_status": "0", "recid": "2744", "relation": {}, "relation_version_is_last": true, "title": ["予測誤差の幾何学的関係による表面筋電図解析"], "weko_shared_id": null}
  1. 060 工学部
  2. 10 学術雑誌論文
  3. 10 査読済論文
  1. 0 資料タイプ別
  2. 01 学術雑誌論文

予測誤差の幾何学的関係による表面筋電図解析

http://hdl.handle.net/10191/20185
http://hdl.handle.net/10191/20185
9715672e-60e9-4725-ba22-38d86a4b2dda
名前 / ファイル ライセンス アクション
24_2_80-85.pdf 24_2_80-85.pdf (926.5 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2012-10-24
タイトル
タイトル 予測誤差の幾何学的関係による表面筋電図解析
タイトル
言語 en
タイトル 予測誤差の幾何学的関係による表面筋電図解析
言語
言語 jpn
資源タイプ
資源 http://purl.org/coar/resource_type/c_6501
タイプ journal article
その他のタイトル
その他のタイトル Analysis of Surface Electromyogram by the Geometrical Relationship of Prediction Error Vectors
著者 木竜, 徹

× 木竜, 徹

WEKO 38807

木竜, 徹

Search repository
飯島, 泰蔵

× 飯島, 泰蔵

WEKO 38808

飯島, 泰蔵

Search repository
斉藤, 義明

× 斉藤, 義明

WEKO 38809

斉藤, 義明

Search repository
山鹿, 卓郎

× 山鹿, 卓郎

WEKO 38810

山鹿, 卓郎

Search repository
石岡, 靖

× 石岡, 靖

WEKO 38811

石岡, 靖

Search repository
著者別名
識別子 38812
識別子Scheme WEKO
姓名 Kiryu, Tohru
著者別名
識別子 38813
識別子Scheme WEKO
姓名 Iijima, Taizo
著者別名
識別子 38814
識別子Scheme WEKO
姓名 Saitoh, Yoshiaki
著者別名
識別子 38815
識別子Scheme WEKO
姓名 Yamaga, Takuo
著者別名
識別子 38816
識別子Scheme WEKO
姓名 Ishioka, Kiyoshi
抄録
内容記述タイプ Abstract
内容記述 It has been reported that the mode of muscle activity is concerned with the power spectrum pattern of surface electromyogram (EMG), in so far as the signal is steadily ergodic in the stochastic process. In this paper, a new deterministic method is proposed for characterization of the non-stationary EMG which varies dynamically in time. An AR (auto-regressive) model is suitable to explain the almost periodical EMG. When the parameters of this model are calculated by the least square estimate (LSE), it is important that the (i+1) th order of forward and the (i) th order of backward prediction error vectors be orthogonal to each other. Therefore, the non-stationariness of EMG is characterized from the looseness of the orthogonality, if these vectors at any interval are obtained as the outputs from the standard filter (SDF), which is defined in a stationary interval by the LSE. Practically, {JFBEO(i)}, which resembles the similarity function, is used for characterization. When an SDF was prepared with the masticatory EMG during the maximum clenching, decrease in the order of AR model appeared for 50%, 25% clenching. At the onset and the ending phase of EMG during the tapping movement, the order also decreased gradually toward the silent phase. The physiological meaning of the order has not yet been clarified, but this method may be useful to understanding the transition period of EMG, which is concerned with excitation and inhibition.
書誌情報 医用電子と生体工学
en : 医用電子と生体工学

巻 24, 号 2, p. 80-85, 発行日 1986-04
出版者
出版者 日本ME学会
ISSN
収録物識別子タイプ ISSN
収録物識別子 00213292
書誌レコードID
収録物識別子タイプ NCID
収録物識別子 AN00016981
著者版フラグ
値 publisher
戻る
0
views
See details
Views

Versions

Ver.1 2021-03-01 20:26:00.899440
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3