WEKO3
アイテム
{"_buckets": {"deposit": "3b31567e-cd11-4f99-9ad0-f8a4698085af"}, "_deposit": {"id": "2736", "owners": [], "pid": {"revision_id": 0, "type": "depid", "value": "2736"}, "status": "published"}, "_oai": {"id": "oai:niigata-u.repo.nii.ac.jp:00002736", "sets": ["454", "425"]}, "item_5_alternative_title_1": {"attribute_name": "その他のタイトル", "attribute_value_mlt": [{"subitem_alternative_title": "Development of the Skeletal Muscle Stimulator with Resonant Type Transmission Function"}]}, "item_5_biblio_info_6": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1997-03", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "70", "bibliographicPageStart": "64", "bibliographicVolumeNumber": "35", "bibliographic_titles": [{"bibliographic_title": "医用電子と生体工学"}, {"bibliographic_title": "医用電子と生体工学", "bibliographic_titleLang": "en"}]}]}, "item_5_description_4": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "In order to investigate the technique of cardiac assistance using skeletal muscle (Cardiomyoplasty) we are developing an implantable skeletal muscle stimulator that responds to muscle fatigue. The stimulator has a resonant circuit to transmit internal information using the carrier waves from the external program head. The stimulator can also control the synchronization ratio automatically using the peak value of the impulse response from an acceleration sensor to estimate muscle fatigue. In this series of animal experiments we verified the functions of both data transmission by the resonant circuit and automatic control of the synchronization ratio. Our results suggest that the stimulator can be used to automatically control muscle stimulation in Dynamic Cardiomyoplasty.", "subitem_description_type": "Abstract"}]}, "item_5_full_name_3": {"attribute_name": "著者別名", "attribute_value_mlt": [{"nameIdentifiers": [{"nameIdentifier": "38730", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Makino, Hideo"}]}, {"nameIdentifiers": [{"nameIdentifier": "38731", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Sato, Eiichi"}]}, {"nameIdentifiers": [{"nameIdentifier": "38732", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Kuroda, Hideo"}]}, {"nameIdentifiers": [{"nameIdentifier": "38733", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Shinohara, Masanori"}]}, {"nameIdentifiers": [{"nameIdentifier": "38734", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Takano, Tamaki"}]}, {"nameIdentifiers": [{"nameIdentifier": "38735", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Watanabe, Kuniyoshi"}]}, {"nameIdentifiers": [{"nameIdentifier": "38736", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Fukaya, Yukio"}]}, {"nameIdentifiers": [{"nameIdentifier": "38737", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Amano, Jun"}]}, {"nameIdentifiers": [{"nameIdentifier": "38738", "nameIdentifierScheme": "WEKO"}], "names": [{"name": "Mitamura, Yoshinori"}]}]}, "item_5_publisher_7": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "日本生体医工学会"}]}, "item_5_select_19": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_select_item": "publisher"}]}, "item_5_source_id_11": {"attribute_name": "書誌レコードID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00016981", "subitem_source_identifier_type": "NCID"}]}, "item_5_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "00213292", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "牧野, 秀夫"}], "nameIdentifiers": [{"nameIdentifier": "38721", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐藤, 栄一"}], "nameIdentifiers": [{"nameIdentifier": "38722", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "黒田, 秀雄"}], "nameIdentifiers": [{"nameIdentifier": "38723", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "篠原, 正典"}], "nameIdentifiers": [{"nameIdentifier": "38724", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高野, 環"}], "nameIdentifiers": [{"nameIdentifier": "38725", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "渡辺, 邦芳"}], "nameIdentifiers": [{"nameIdentifier": "38726", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "深谷, 幸雄"}], "nameIdentifiers": [{"nameIdentifier": "38727", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "天野, 純"}], "nameIdentifiers": [{"nameIdentifier": "38728", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "三田村, 好矩"}], "nameIdentifiers": [{"nameIdentifier": "38729", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2019-07-29"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "N35_1_64-70.pdf", "filesize": [{"value": "840.0 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 840000.0, "url": {"label": "N35_1_64-70.pdf", "url": "https://niigata-u.repo.nii.ac.jp/record/2736/files/N35_1_64-70.pdf"}, "version_id": "83cc2a05-b3be-4ec2-b48f-329552889344"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "共振型プログラム通信機能を有する植込み型骨格筋刺激装置の開発", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "共振型プログラム通信機能を有する植込み型骨格筋刺激装置の開発"}, {"subitem_title": "共振型プログラム通信機能を有する植込み型骨格筋刺激装置の開発", "subitem_title_language": "en"}]}, "item_type_id": "5", "owner": "1", "path": ["454", "425"], "permalink_uri": "http://hdl.handle.net/10191/25892", "pubdate": {"attribute_name": "公開日", "attribute_value": "2014-02-28"}, "publish_date": "2014-02-28", "publish_status": "0", "recid": "2736", "relation": {}, "relation_version_is_last": true, "title": ["共振型プログラム通信機能を有する植込み型骨格筋刺激装置の開発"], "weko_shared_id": null}
共振型プログラム通信機能を有する植込み型骨格筋刺激装置の開発
http://hdl.handle.net/10191/25892
http://hdl.handle.net/10191/25892097a6070-78fa-4042-94b5-dc7b59070f9d
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2014-02-28 | |||||
タイトル | ||||||
タイトル | 共振型プログラム通信機能を有する植込み型骨格筋刺激装置の開発 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | 共振型プログラム通信機能を有する植込み型骨格筋刺激装置の開発 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源 | http://purl.org/coar/resource_type/c_6501 | |||||
タイプ | journal article | |||||
その他のタイトル | ||||||
その他のタイトル | Development of the Skeletal Muscle Stimulator with Resonant Type Transmission Function | |||||
著者 |
牧野, 秀夫
× 牧野, 秀夫× 佐藤, 栄一× 黒田, 秀雄× 篠原, 正典× 高野, 環× 渡辺, 邦芳× 深谷, 幸雄× 天野, 純× 三田村, 好矩 |
|||||
著者別名 | ||||||
識別子 | 38730 | |||||
識別子Scheme | WEKO | |||||
姓名 | Makino, Hideo | |||||
著者別名 | ||||||
識別子 | 38731 | |||||
識別子Scheme | WEKO | |||||
姓名 | Sato, Eiichi | |||||
著者別名 | ||||||
識別子 | 38732 | |||||
識別子Scheme | WEKO | |||||
姓名 | Kuroda, Hideo | |||||
著者別名 | ||||||
識別子 | 38733 | |||||
識別子Scheme | WEKO | |||||
姓名 | Shinohara, Masanori | |||||
著者別名 | ||||||
識別子 | 38734 | |||||
識別子Scheme | WEKO | |||||
姓名 | Takano, Tamaki | |||||
著者別名 | ||||||
識別子 | 38735 | |||||
識別子Scheme | WEKO | |||||
姓名 | Watanabe, Kuniyoshi | |||||
著者別名 | ||||||
識別子 | 38736 | |||||
識別子Scheme | WEKO | |||||
姓名 | Fukaya, Yukio | |||||
著者別名 | ||||||
識別子 | 38737 | |||||
識別子Scheme | WEKO | |||||
姓名 | Amano, Jun | |||||
著者別名 | ||||||
識別子 | 38738 | |||||
識別子Scheme | WEKO | |||||
姓名 | Mitamura, Yoshinori | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In order to investigate the technique of cardiac assistance using skeletal muscle (Cardiomyoplasty) we are developing an implantable skeletal muscle stimulator that responds to muscle fatigue. The stimulator has a resonant circuit to transmit internal information using the carrier waves from the external program head. The stimulator can also control the synchronization ratio automatically using the peak value of the impulse response from an acceleration sensor to estimate muscle fatigue. In this series of animal experiments we verified the functions of both data transmission by the resonant circuit and automatic control of the synchronization ratio. Our results suggest that the stimulator can be used to automatically control muscle stimulation in Dynamic Cardiomyoplasty. | |||||