{"created":"2021-03-01T06:06:26.430200+00:00","id":2714,"links":{},"metadata":{"_buckets":{"deposit":"47386e23-1733-4c60-8043-c5c2a43ab8c1"},"_deposit":{"id":"2714","owners":[],"pid":{"revision_id":0,"type":"depid","value":"2714"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00002714","sets":["453:454","518:519:520"]},"item_5_alternative_title_1":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Ultrasonic Technique for Contact Mechanism Estimation of an Artificial Hip Joint"}]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1998-09","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"118","bibliographicPageStart":"111","bibliographicVolumeNumber":"10","bibliographic_titles":[{"bibliographic_title":"ライフサポート"},{"bibliographic_title":"ライフサポート","bibliographic_titleLang":"en"}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"An ultrasonic technique was developed to study the characteristics for contact mechanics of an artificial hip joint. Total Hip Replacement model was used to determine contact pressure distribution on an artificial aceptabular cup subjected to compressive load ranged from196N to 588N in four femur positions. The contact pressure was found to be nonuniform and less than 6MPa. It was shown that the tendency of the pressure distribution is in agreement with that obtained by the computer simulation.Some preliminary results were also presented to illustrate the effect of the direction and the magnitude of the load applied to a stem on the contact pressure distribution on the aceptabular cup and to evaluate the contact mechanism of the artificial hip joint.","subitem_description_type":"Abstract"}]},"item_5_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"38641","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Oda, Masafumi"}]},{"nameIdentifiers":[{"nameIdentifier":"38642","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Sekiguchi, Yukio"}]},{"nameIdentifiers":[{"nameIdentifier":"38643","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Hara, Toshiaki"}]}]},"item_5_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"ライフサポート学会"}]},"item_5_relation_31":{"attribute_name":"異版である","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.jstage.jst.go.jp/article/lifesupport1996/10/3/10_3_111/_pdf","subitem_relation_type_select":"URI"}}]},"item_5_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright (C) 1998 一般社団法人ライフサポート学会"},{"subitem_rights":"本文データは学協会の許諾に基づきJ-Stageから複製したものである"}]},"item_5_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_5_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11947931","subitem_source_identifier_type":"NCID"}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13419455","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"尾田, 雅文"}],"nameIdentifiers":[{"nameIdentifier":"38638","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"関口, 行雄"}],"nameIdentifiers":[{"nameIdentifier":"38639","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"原, 利昭"}],"nameIdentifiers":[{"nameIdentifier":"38640","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-07-29"}],"displaytype":"detail","filename":"10_3_111-118.pdf","filesize":[{"value":"757.2 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"10_3_111-118.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/2714/files/10_3_111-118.pdf"},"version_id":"4b762b10-eb35-44e7-89b5-c089c7ab3cdc"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Experimental Stress Analysis","subitem_subject_scheme":"Other"},{"subitem_subject":"Finite Element Method","subitem_subject_scheme":"Other"},{"subitem_subject":"Contact Pressure","subitem_subject_scheme":"Other"},{"subitem_subject":"Super Sonic Waves","subitem_subject_scheme":"Other"},{"subitem_subject":"Artificial Hip Joint","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"超音波を利用した人工股関節の接触メカニズム評価","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"超音波を利用した人工股関節の接触メカニズム評価"},{"subitem_title":"超音波を利用した人工股関節の接触メカニズム評価","subitem_title_language":"en"}]},"item_type_id":"5","owner":"1","path":["454","520"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-04-15"},"publish_date":"2014-04-15","publish_status":"0","recid":"2714","relation_version_is_last":true,"title":["超音波を利用した人工股関節の接触メカニズム評価"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-15T03:35:56.746844+00:00"}