{"created":"2021-03-01T06:06:26.239991+00:00","id":2711,"links":{},"metadata":{"_buckets":{"deposit":"41912734-d59f-4b0e-b318-e67f454e06ce"},"_deposit":{"id":"2711","owners":[],"pid":{"revision_id":0,"type":"depid","value":"2711"},"status":"published"},"_oai":{"id":"oai:niigata-u.repo.nii.ac.jp:00002711","sets":["453:454","518:519:520"]},"item_5_alternative_title_1":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Ultrasonic Measurement System using Wavelet Analysis for the Lower Leg"}]},"item_5_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2005-11","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"108","bibliographicPageStart":"100","bibliographicVolumeNumber":"17","bibliographic_titles":[{"bibliographic_title":"ライフサポート"},{"bibliographic_title":"ライフサポート","bibliographic_titleLang":"en"}]}]},"item_5_description_4":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Checking the fit between a prosthetic socket and a residual limb is important for functional prostheses. Designing a prosthetic socket using a CAD system and checking the above mentioned fit by analyzing the deformation and stress under the weight of an amputee requires a three-dimensional model of the residual limb that includes not only the surface, but also the fat, muscle and bone. An ultrasonic measurement system, including a probe that three-dimensionally measures the external surface shape and the shapes of internal tissues simultaneously was developed. The system uses wavelet analysis to define the positions of the boundaries between each tissue. A cone-shaped aluminum test object was measured using the system, which was shown to be capable of measuring radius with an error of 0.6mm and slope with an error of 6%. In addition, the lower legs were measured, and the surface, muscles and bone boundaries were defined by wavelet analysis. The results of these measurements were compared to MRI cross sectional data, and the average error for the leg surface, muscles and tibia were 1.7mm, 2.4mm and 1.9mm, respectively, for boundaries that were determined correctly.","subitem_description_type":"Abstract"}]},"item_5_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"38617","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Asai, Kanako"}]},{"nameIdentifiers":[{"nameIdentifier":"38618","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Hanafusa, Akihiko"}]},{"nameIdentifiers":[{"nameIdentifier":"38619","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Fuwa, Teruhiko"}]},{"nameIdentifiers":[{"nameIdentifier":"38620","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Oda, Masafumi"}]},{"nameIdentifiers":[{"nameIdentifier":"38621","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Nakayama, Tsuyoshi"}]}]},"item_5_publisher_7":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"ライフサポート学会"}]},"item_5_relation_31":{"attribute_name":"異版である","attribute_value_mlt":[{"subitem_relation_type":"isVersionOf","subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.jstage.jst.go.jp/article/lifesupport1996/17/3/17_3_100/_pdf","subitem_relation_type_select":"URI"}}]},"item_5_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright (C) 2005 一般社団法人ライフサポート学会"},{"subitem_rights":"本文データは学協会の許諾に基づきJ-Stageから複製したものである"}]},"item_5_select_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_select_item":"publisher"}]},"item_5_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA11947931","subitem_source_identifier_type":"NCID"}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13419455","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"浅井, 協子"}],"nameIdentifiers":[{"nameIdentifier":"38612","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"花房, 昭彦"}],"nameIdentifiers":[{"nameIdentifier":"38613","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"不破, 輝彦"}],"nameIdentifiers":[{"nameIdentifier":"38614","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"尾田, 雅文"}],"nameIdentifiers":[{"nameIdentifier":"38615","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中山, 剛"}],"nameIdentifiers":[{"nameIdentifier":"38616","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-07-29"}],"displaytype":"detail","filename":"17_3_100-108.pdf","filesize":[{"value":"1.4 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"17_3_100-108.pdf","url":"https://niigata-u.repo.nii.ac.jp/record/2711/files/17_3_100-108.pdf"},"version_id":"95085886-fe9c-4a56-a676-78c06a911d38"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Prosthetic socket","subitem_subject_scheme":"Other"},{"subitem_subject":"Lower leg","subitem_subject_scheme":"Other"},{"subitem_subject":"Ultrasonic measurement","subitem_subject_scheme":"Other"},{"subitem_subject":"Wavelet analysis","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Wavelet 解析を利用した下腿の超音波計測システムに関する研究","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Wavelet 解析を利用した下腿の超音波計測システムに関する研究"},{"subitem_title":"Wavelet 解析を利用した下腿の超音波計測システムに関する研究","subitem_title_language":"en"}]},"item_type_id":"5","owner":"1","path":["454","520"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-04-15"},"publish_date":"2014-04-15","publish_status":"0","recid":"2711","relation_version_is_last":true,"title":["Wavelet 解析を利用した下腿の超音波計測システムに関する研究"],"weko_creator_id":"1","weko_shared_id":null},"updated":"2022-12-15T03:35:57.167116+00:00"}